7368 Intelligent Services Access 

Manager ONT

7368 ISAM ONT BGW320-505 Product Guide

3FE-47753-AAAA-TCZZA

Issue: 01

 

7368 ISAM ONT BGW320-505 Product Guide

Release 06.02.00b | October 2019 | Edition 01

Summary of Contents for 7368 ISAM ONT BGW320-505

Page 1: ...l Use pursuant to applicable agreements 7368 Intelligent Services Access Manager ONT 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 7368 ISAM ONT BGW320 505 Product Guide Release 06 02 00b October 2019 Edition 01 ...

Page 2: ... information presented is subject to change without notice No responsibility is assumed for inaccuracies contained herein 2019 Nokia Contains proprietary trade secret information which is the property of Nokia and must not be made available to or copied or used by anyone outside Nokia without its written authorization Not to be used or disclosed except in accordance with applicable agreements Rele...

Page 3: ...dministrators operators and maintenance personnel involved in installing upgrading or maintaining the ONTs 1 3 Required knowledge The reader must be familiar with general telecommunications principles 1 4 Acronyms and initialisms The expansions and optional descriptions of most acronyms and initialisms appear in the glossary 1 5 Assistance and ordering phone numbers Nokia provides global technical...

Page 4: ...Safety information For safety information see the appropriate safety guidelines chapter 1 8 Documents Documents are available using ALED or OLCS Procedure 1 To download a ZIP file package of the customer documentation 1 Navigate to https customer nokia com support s and enter your user name and password If you are a new user and require access to this service please contact your Nokia sales repres...

Page 5: ... by title and part number You can filter this list using the Release drop down menu 4 Click on the PDF to open or save the file 1 9 Special information The following are examples of how special information is presented in this document Danger Danger indicates that the described activity or situation may result in serious personal injury or death for example high voltage or electric shock hazards W...

Page 6: ...p indicates 1 This step offers two options You must choose one of the following a This is one option b This is another option 2 You must perform this step Procedure 4 Example of required substeps in a procedure At step 1 you must perform a series of substeps within a step At step 2 you must do what the step indicates 1 This step has a series of substeps that you must perform to complete the step Y...

Page 7: ...re 5 To search multiple PDF files for a common term 1 Open Adobe Acrobat Reader 2 Choose Edit Search from the Acrobat Reader main menu The Search PDF panel appears 3 Enter the search criteria 4 Click on the All PDF Documents In radio button 5 Select the folder in which to search using the drop down menu 6 Click on the Search button Acrobat Reader displays the search results You can expand the entr...

Page 8: ...Preface 8 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 Release 06 02 00b October 2019 Edition 01 ...

Page 9: ...stibility requirements compliance 18 2 3 Electrical safety guidelines 18 2 3 1 Power supplies 18 2 3 2 Cabling 18 2 3 3 Protective earth 19 2 4 ESD safety guidelines 19 2 5 Laser safety guidelines 19 2 5 1 Normal laser operation 20 2 5 2 Location class 20 2 6 Environmental requirements 20 3 BGW320 505 unit data sheet 21 3 1 BGW320 505 part numbers and identification 21 3 2 BGW320 505 general descr...

Page 10: ...Fi standards and certifications 33 3 9 1 3 Wi Fi GUI features 33 3 9 2 BGW320 505 ONT considerations and limitations 33 4 Install an BGW320 505 indoor ONT 35 4 1 Purpose 35 4 2 General 35 4 3 Prerequisites 35 4 4 Safety information 36 4 5 Procedure 37 5 Replace an BGW320 505 indoor ONT 41 5 1 Purpose 41 5 2 General 41 5 3 Prerequisites 41 5 4 Safety information 42 5 5 Procedure 43 Release 06 02 00...

Page 11: ... 505 ONT unit 23 Figure 2 BGW320 505 ONT bottom view 24 Figure 3 BGW320 505 ONT front and side view 24 Figure 4 BGW320 505 ONT connections 25 4 Install an BGW320 505 indoor ONT 35 Figure 5 BGW320 505 ONT connections 38 5 Replace an BGW320 505 indoor ONT 41 Figure 6 BGW320 505 ONT connections 44 Release 06 02 00b October 2019 Edition 01 ...

Page 12: ...12 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 Release 06 02 00b October 2019 Edition 01 ...

Page 13: ... 4 BGW320 505 indoor ONT physical connections 27 Table 5 BGW320 505 service LED indications 28 Table 6 BGW320 505 indoor ONT physical specifications 29 Table 7 BGW320 505 indoor ONT power consumption specifications 29 Table 8 BGW320 505 indoor ONT environmental specifications 30 Table 9 BGW320 505 indoor ONT capacity for GEM ports and T CONTs 30 Table 10 Responsible party contact information 31 Ta...

Page 14: ...14 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 Release 06 02 00b October 2019 Edition 01 ...

Page 15: ...ger box indicates that the described activity or situation may pose a threat to personal safety It calls attention to a situation or procedure which if not correctly performed or adhered to may result in death or serious physical harm Do not proceed beyond a Danger box until the indicated conditions are fully understood and met The following is an example of the Warning box The Warning box indicat...

Page 16: ...s labeled with specific safety compliance information and instructions that are related to a variant of the ONT Observe the instructions on the safety labels Table 1 provides examples of the text in the various ONT safety labels Table 1 Safety labels 2 2 Safety standards compliance This section describes the ONT compliance with North American safety standards Caution 1 Possibility of service inter...

Page 17: ...terference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rece...

Page 18: ...t 2 3 1 Power supplies The use of any non Nokia approved power supplies or power adapters is not supported or endorsed by Nokia Such use will void any warranty or support contract with Nokia Such use greatly increases the danger of damage to equipment or property 2 3 2 Cabling The following are the guidelines regarding cables used for the ONT equipment Use only cables approved by the relevant nati...

Page 19: ...he use of air conditioning 2 5 Laser safety guidelines Observe the following instructions when you perform installation operations and maintenance tasks on the ONT equipment Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system Observe the following danger for laser hazard Eyes can be damage...

Page 20: ...be damaged when they exposed to a laser beam Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module 2 5 2 Location class Use cable supports and guides to protect the receptacles from strain 2 6 Environmental requirements See the ONT technical specification documentation for temperature ranges for ONTs Danger Risk of eye damage by lase...

Page 21: ...ification of BGW320 505 indoor ONT Ordering kit part number Provisioning number Description CLEI CPR ECI Bar code 3FE 47753 AA Customer specific variant 3FE 47753 AA Package P ONT unit with one RJ 14 POTS port three 10 100 1000 BaseT Ethernet interfaces and one 5G 2 5G 1G Ethernet port This ONT has one USB 2 0 port with a Type A connector This ONT also supports tri band Wi Fi 5 GHz low band 5 GHz ...

Page 22: ...to subscriber devices The ONT is compatible with all existing subscriber equipment including analog phones with both tone and rotary dial capabilities cordless phones modems fax machines and caller ID boxes Type I Type II and Type III BGW320 505 ONTs feature one 5G Ethernet port The BGW320 505 also provides three 10 100 1000 BaseT Ethernet ports 5 GHz low band 5 GHz high band and 2 4 GHz The ONT p...

Page 23: ...68 ISAM ONT BGW320 505 Product Guide BGW320 505 unit data sheet Issue 01 3FE 47753 AAAA TCZZA 23 Figure 1 BGW320 505 ONT unit Figure 2 shows the bottom of the ONT Release 06 02 00b October 2019 Edition 01 ...

Page 24: ...BGW320 505 ONT bottom view Figure 3 shows the front and side views of the BGW320 505 ONT A WPS button is visible on the front of the unit Figure 3 BGW320 505 ONT front and side view Figure 4 shows the physical connections for the BGW320 505 indoor ONT 28516 Front Side Release 06 02 00b October 2019 Edition 01 ...

Page 25: ...auto sensing One POTS port for carrier grade voice services One USB 2 0 Type A port Triple Play services including voice video and high speed Internet access the maximum transmit power is 9 dBm Traffic classification and QoS capability Support for fax services Built in layer 2 switch Line Rate L2 traffic 1 GB RAM and 4 GB EMMC memory card in the board IP video distribution Optics that support rece...

Page 26: ...ranslation NAPT IGMP snooping and proxy v2 v3 Traffic classification and QoS capability OMCI TR 069 and Web GUI management support Performance monitoring and alarm reporting Remote software image downloading and activation IP MAC URL filter Multi level firewall and ACL 3 2 1 TR69 authentication using TLS and CA certificates BGW320 505 ONTs support TLS as well as ACS authentication using SHA 256 pr...

Page 27: ... physical connections for the BGW320 505 indoor ONT Table 4 BGW320 505 indoor ONT physical connections ONT type and model Maximum capacity 10 100 1000 BaseT 5G Ethernet port 5 GHz low band Wi Fi 1 5 GHz high band Wi Fi 1 2 4 GHz Wi Fi 1 SFP ONT BGW320 505 3 1 1 1 1 1 1 Connection Description ONT One ONT connection is supported through an RJ 45 cable The ONT connection provides Ethernet access to h...

Page 28: ...wer cord connectors are securely and completely plugged into receptacles Do not use the power adapter in an outdoor environment or any wet locations Protect the power adapter from liquids The conditions above may cause fire short circuit electrocution or shock injury USB This connection is provided through one USB 2 0 Type A port The voltage rate is 5V SFP This connection is provided through a SFP...

Page 29: ...nection is configured for use No signal on one pair of a bonded pair connection as identified through manual or G 997 1 communication Red Red flashing Slow Broadband connection fails to be established for more than three consecutive minutes or there is no signal on all broadband connections Red flashing Fast The device is attempting to connect to an IP and failed Red POST failure Not bootable A de...

Page 30: ...iques Electrostatic discharge immunity test EN 61000 4 2 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields EN 61000 4 2 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test FCC CFR 47 Part 15 Subparts B C and E 3 8 1 Responsible party Table 10 lists the party in the US responsible for this ONT Mounting...

Page 31: ...has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interferenc...

Page 32: ...peration is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 3 9 BGW320 505 special considerations BGW320 505 are package P ONTs 3 9 1 Wi Fi service BGW320 505 indoor ONTs feature Wi Fi service as well as voice and data services Wi Fi is a wirele...

Page 33: ... 1 3 Wi Fi GUI features BGW320 505 indoor ONTs have HTML based Wi Fi configuration GUIs 3 9 2 BGW320 505 ONT considerations and limitations Table 11 lists the considerations and limitations for Package P BGW320 505 ONTs Table 11 BGW320 505 ONT considerations and limitations Considerations and limitations This device is restricted to indoor use in accordance with proper ventilation as described in ...

Page 34: ...BGW320 505 unit data sheet 34 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 Release 06 02 00b October 2019 Edition 01 ...

Page 35: ...erequisites 4 4 Safety information 4 5 Procedure 4 1 Purpose This chapter provides the steps to install a BGW320 505 indoor ONT 4 2 General The steps listed in this chapter describe mounting and cabling for BGW320 505 indoor ONTs 4 3 Prerequisites You need the following items before beginning the installation all required cables Release 06 02 00b October 2019 Edition 01 ...

Page 36: ...e used when removing the fiber access cover of the indoor ONT Warning 2 Do not directly connect the 10G PON ONT to the 10G PON OLT Caution Keep indoor ONTs out of direct sunlight Prolonged exposure to direct sunlight can damage the unit Note 1 Observe the local and national laws and regulations that may be applicable to this installation Note 2 Observe the following The indoor ONT should be instal...

Page 37: ...pment The ONT mounting requirements are place the unit in a vertical upright position with the feet and grill facing down and the flat top facing up allow a minimum 100 mm clearance above the top cover do not place any heat source directly above the top cover or below the bottom cover Warning There is a risk of overheating if the BGW320 is not properly ventilated The unit should not be placed in a...

Page 38: ...1 Figure 5 BGW320 505 ONT connections 3 Connect the Ethernet cables to the ONT and GE ports see Figure 5 for the location of these ports 4 Connect a telephone to the RJ 14 POTS port Contact your service provider for details especially if you have an alarm system Release 06 02 00b October 2019 Edition 01 ...

Page 39: ...ndoor ONT as shown in Figure 5 ii Press the Reset button for less than 10 seconds to reboot the ONT Press the Reset button for 10 seconds to reset the ONT to its factory defaults 12 STOP This procedure is complete Danger Fiber cables transmit invisible laser light To avoid eye damage or blindness never look directly into fibers connectors or adapters Warning Be careful to maintain a bend radius of...

Page 40: ...Install an BGW320 505 indoor ONT 40 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 Release 06 02 00b October 2019 Edition 01 ...

Page 41: ...erequisites 5 4 Safety information 5 5 Procedure 5 1 Purpose This chapter provides the steps to replace BGW320 505 indoor ONTs 5 2 General The steps listed in this chapter describe mounting and cabling for BGW320 505 indoor ONTs 5 3 Prerequisites You need the following items before beginning the installation all required cables Release 06 02 00b October 2019 Edition 01 ...

Page 42: ... used when removing the fiber access cover of the indoor ONT Warning 2 Do not directly connect the 10G PON ONT to the 10G PON OLT Caution Keep indoor ONTs out of direct sunlight Prolonged exposure to direct sunlight can damage the unit Note 1 Observe the local and national laws and regulations that may be applicable to this installation Note 2 Observe the following The indoor ONT should be install...

Page 43: ...not required The ONT and the services can remain in service IS i Use the RTRV ONT command to verify the ONT status and th associated services Record the serial number or the SLID of the ONT displayed in the command output Example RTRV ONT ONT 1 1 1 1 1 ii If the ONT is in service place the ONT in OOS state Example ED ONT ONT 1 1 1 1 1 2 Power down the unit by disconnecting the power cable see Figu...

Page 44: ...i Unplug the fiber optic cable from the SFP connector ii Attach a fiber dust cover to the end of the SFP connector 5 Replace the ONT with a new unit For details Install an BGW320 505 indoor ONT 6 Connect the Ethernet cables to the ONT and GE ports see Figure 6 for the location of these ports Danger Fiber cables transmit invisible laser light To avoid eye damage or blindness never look directly int...

Page 45: ...oltage status and optical signal levels see the 7368 Hardware and Cabling Installation Guide 13 Activate and test the services see the 7368 Hardware and Cabling Installation Guide 14 If necessary reset the ONT i Locate the Reset button on a BGW320 505 indoor ONT as shown in Figure 6 ii Press the Reset button for less than 10 seconds to reboot the ONT Press the Reset button for 10 seconds to reset ...

Page 46: ...Replace an BGW320 505 indoor ONT 46 7368 ISAM ONT BGW320 505 Product Guide 3FE 47753 AAAA TCZZA Issue 01 Release 06 02 00b October 2019 Edition 01 ...

Page 47: ...duct support Customer documentation Customer Documentation Welcome Page Technical Support Customer Documentation Technical Support Documentation feedback Customer Documentation Feedback Release 06 02 00b October 2019 Edition 01 ...

Page 48: ...Copyright 2019 Nokia 3FE 47753 AAAA TCZZA Release 06 02 00b October 2019 Edition 01 ...