background image

Features

• Complies with IEEE 802.3 10Base-FL standard.

• A complete interface of the AUI to fiber optic cable link.

• Flexible selection for half-duplex or full-duplex mode

• Supports data transfer rate up to 20Mbps for full-duplex

• Capability for driving the fiber optic cable segment up

to 2000M (6560 ft.).

• Selectable SQE test function

• Link integrity test for automatic checking of fiber

optic cable lines

• Supports LED indications for the Transmit, Receive,

Link, and Collision status.

• Dimension:

42mm x 65mm x 20mm

• Input voltage: 10.2 to 15.75 VDC

• Input current: 250mA @12 VDC (typical)

Connectors & Cables

AUI connection

: D-sub 15 pin male connector

AUI drop cable (50 meters max.)

The AUI connector is used for attaching the transceiver to

the AUI port provided by an Ethernet device such as an

Ethernet MAC controller, an Ethernet repeater, or an

Ethernet concentrator via an AUI drop cable. The pin

assignments are shown as below:

Pin Assignments of the AUI (DB15) Connector

Pin

Name

Pairs

Use

3

DO +

Transmit

Data Out (+)

10

DO -

Pair

Data Out (-)

11

DO S

Data Out Shield

5

DI +

Receive

Data In +

12

DI -

Pair

Data In -

4

DI S

Data In Shield

7

CO +

Optional

Control Out +

15

CO -

Pair

Control Out -

8

CO S

Control Shield

2

CI +

Collision

Control In +

9

CI -

Pair

Control In -

1

CI S

Control Shield

6

VC

Power

Voltage Common

13

VP

Pair

Voltage Plus

14

VS

Voltage Shield

Installation Guide

Ethernet Fiber Optic Transceiver

Model: KT-10F v2

DOC.G990126-KT10F-V2-K

P/N:  750-0125-001

General Description

The KT-10F Ethernet transceiver complies with IEEE 802.3

transceiver specifications and 10Mbps Ethernet CSMA/

CD operation to extend the your existing Ethernet segment

up to 2000 meters by using fiber optic cable.

The transceiver is attached to the AUI connector of an

Ethernet device via standard AUI cable.

Fiber connection: 

ST connectors

Fiber optic cable

Two ST style connectors are provided for connection to

fiber optic cable. One is for transmitting and the other is

for receiving. See the following figure:

Fiber mode: multimode
Wavelength: 850

µ

m

The transceiver can operate with a variety of fiber optic

sizes, for example, 50/125

µ

m, 62.5/125

µ

m, and 100/140

µ

m.

Setting Switches

There are two switches which are accessible on the side of

the transceiver enclosure. The functions of these switches

are:

SW#

Setting

Function

SW1

On

Enable SQE test (factory default)

Off

Disable SQE test (for repeater device)

SW2

On

Full-duplex mode

Off

Half-duplex mode (factory default)

Important:

The transceiver is shipped from the factory with the SQE

test enabled. If the transceiver is connected to an Ethernet

repeater, a 10Base-T hub, or a wiring concentrator, the SQE

test function should be disabled.

Reviews: