background image

Configuration Guide

Issue 2.00

Summary of Contents for Univerge SV8100

Page 1: ...Configuration Guide Issue 2 00...

Page 2: ......

Page 3: ...e registered trademarks of NEC Corporation and Electra Elite is a registered trademark of NEC America Inc Windows is a registered trademark of Microsoft Corporation AT T is a registered trademark of A...

Page 4: ......

Page 5: ...The manuals are described in this preface THIS MANUAL This manual provides general information about the system its features system configuration and standards This manual provides an overview of the...

Page 6: ...Manual is provided for the system installer This manual has detailed instructions for installing the UNIVERGE SV8100 chassis blades multiline terminals and optional equipment UNIVERGE SV8100 Programmi...

Page 7: ...UNIVERGE SV8100 system includes the batteries listed below When disposing of these batteries you must comply with applicable federal and state regulations regarding proper disposal procedures Table R...

Page 8: ...id waste management officials for other information regarding the environmentally sound collection recycling and disposal of the battery Nickel Cadmium or sealed lead batteries must be returned to a f...

Page 9: ...BE RECYCLED OR DISPOSED OF PROPERLY MUST NOT BE DISPOSED OF IN MUNICIPAL WASTE CONTAINS SEALED LEAD BATTERY BATTERY MUST BE RECYCLED MUST NOT BE DISPOSED OF IN MUNICIPAL WASTE Pb Ni Cd CONTAINS NICKEL...

Page 10: ...res should match the supported features of the system For an overview of the supported features refer to the detailed documentation that comes with this system contact your local NEC representative or...

Page 11: ...d that a fine may be imposed for illegal disposal of electrical and electronic products via the general municipal waste stream To facilitate separate disposal and environmentally sound recycling arran...

Page 12: ...Issue 2 00 UNIVERGE SV8100 R 6 Regulatory NOTES...

Page 13: ...and IP Multiline Telephone Line Up 1 4 3 1 Modular Design 1 4 3 2 Digital and IP Telephones 1 5 3 2 1 Digital Telephones 1 5 3 2 2 IP Telephones 1 6 3 2 3 Terminal Category Reference 1 8 3 2 4 Upgrad...

Page 14: ...4 Power Requirements 5 11 4 1 Power Supply Specifications 5 11 4 2 Power Supply Consumption 5 12 Section 5 Environmental Conditions 5 12 5 1 Temperature and Humidity 5 12 5 2 Outside Line Types 5 13 5...

Page 15: ...Chime Output 5 18 5 4 8 SMDR Output 5 18 5 4 9 PC Connection 5 18 5 4 10 Relay Contact 5 18 5 5 Battery Backup 5 18 5 5 1 System Backup Optional 5 18 5 5 2 Memory Backup 5 18 5 6 Weights and Dimensio...

Page 16: ...________ 2 7 Number of Nodes A 3 Section 3 SV8100 FeatureNet Considerations A 3 3 1 Trunks A 3 3 2 Maintenance A 4 3 3 Numbering plan A 4 3 4 Operator A 4 3 5 Features not suitable for this configurat...

Page 17: ..._______ LIST OF FIGURES Figure 1 1 UNIVERGE SV8100 CHS2U GW Chassis 1 2 Figure 1 2 UNIVERGE SV8100 CHS2U Chassis Expandability 1 2 Figure 1 3 UNIVERGE SV8100 Telephone Modular Design 1 4 Figure 1 4 Sy...

Page 18: ...00 UNIVERGE SV8100 ___________________________________________________________________________________ vi List of Figures _____________________________________________________________________________...

Page 19: ...tem Capacities Blades 3 3 Table 3 3 Daughter Board Combinations 3 5 Table 3 4 Board Power Factor 3 6 Table 3 5 Maximum Number of Packages Installed 3 7 Table 3 6 Terminal Power Factor 3 7 Table 3 7 IP...

Page 20: ...______________________________________ viii List of Tables ___________________________________________________________________________________ Table 5 10 SV8100 Weights and Dimensions 5 19 Table 5 11...

Page 21: ...tal station ports and can be expanded using three additional 19 chassis to 368 digital station ports Through IP connection and additional chassis the system can be expanded to a maximum of 512 station...

Page 22: ...anded to 368 station ports 184 trunks by adding three chassis a total of four chassis By using IP connection a maximum of 512 station ports 200 trunks are provided by adding additional 19 chassis Refe...

Page 23: ...55 111 222 333 444 444 Data 7 7 14 21 28 28 Dterm 48V 32 80 176 272 368 Total 512 SLT 28V 32 80 176 272 368 SLT 48V 8 20 44 68 92 Dterm IP 512 512 SIP WLAN 512 Analog Trunks COT 16 40 88 136 184 Total...

Page 24: ...se adjustable footplate allows the customer to chose from a variety of height positions that are right for them and their environment Only the DT300 DT700 Dterm Series i telephones Aspire Model C sing...

Page 25: ...ay models The LCD is a full dot black and white display with cursor keys The 10 key dial pad is backlit for easy viewing The 6 button and 2 button telephones are not upgradeable r Value Telephones the...

Page 26: ...6 button and 2 button telephones are not upgradeable r IP Value Telephones the value telephones are offered in 12 button 24 button and 32 button display models as well as a DESI less model The LCD is...

Page 27: ...ports full duplex handsfree operation and PSTN Public Switched Telephone Network adapter for analog operation XML open interface and 10 100 ethernet connectivity are also provided with this telephone...

Page 28: ...d other features 2 button terminal is non display 6 button terminal equipped with LCD and full featured keypad available in black DT 330 Value DTL 8LD DTL 12D DTL 24D DTL 32 D 3 3 8 button DESI less L...

Page 29: ...and feature add on capability available in black and white expands the capability by providing XML display to provide more productivity enhanced applications to the users optional 60 button DSS Consol...

Page 30: ...atibility Comments SV8100 SV8300 Table 1 3 Connectivity of Options Terminal Options IP Terminals Digital Terminals Sophisticated ITL 320C 1 Value ITL 8LD 1 ITL 12D 1 ITL 24D 1 ITL 32D 1 Economy ITL 2E...

Page 31: ...Backlit LCD 3 Except 8LD 1 Unit N A IP DESI less LK LCD Unit N A Built in 3 N A N A Table 1 3 Connectivity of Options Continued Terminal Options IP Terminals Digital Terminals Sophisticated ITL 320C...

Page 32: ...These include Automatic Call Distribution ACD Voice Mail Computer Telephone Integration CTI Unified Messaging Wireless Handsets Station Message Detail Recording SMDR Single Line Telephones External S...

Page 33: ...Message Detail Recording SMDR Facsimile Answering Machine External Speakerphone Headset DSS Console CO PBX Centrex DID Tie FT1 ISDN BRI ISDN PRI UNIVERGE SV8100 Digital and IP Telephones Computer Tel...

Page 34: ...Issue 2 00 UNIVERGE SV8100 1 14 Introduction to UNIVERGE SV8100 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 35: ...or categorize and or restrict trunk calls The system has two types of Forced Account Codes Forced Account Codes Unverified Verified Account Codes Account Code Entry Account Codes are user dialed codes...

Page 36: ...96 analog ports Each PGD 2 U10 ADP requires an unused port on a CD 8DLCA CD 16DLCA blade Ancillary Device Connection Ancillary Device Connection allows installation of selected peripheral ancillary d...

Page 37: ...r enabled Attendant Call Queuing is a permanent non programmable system feature Automatic Call Distribution ACD Automatic Call Distribution ACD uniformly distributes calls among agents of a programmed...

Page 38: ...tation is idle Barge In Barge In permits an extension user to break into another extension user s established call including Conference calls This sets up a Conference type conversation between the in...

Page 39: ...ltiline terminal or the same key can appear on multiple terminals This feature allows efficient call handling when numerous CO calls are received and a limited number of CO line key appearances are av...

Page 40: ...swer Forwarding Call Forwarding Immediate All calls forward immediately to the destination and only the destination rings Call Forwarding with both Ringing All calls forward immediately to the destina...

Page 41: ...the co worker s telephone Call Forwarding with Follow Me reroutes calls from the destination extension To reroute calls from the initiating forwarding extension use Call Forwarding Call Forwarding Of...

Page 42: ...Department Group all ring mode Door Box Virtual Extension The use of monitoring recording or listening devices to eavesdrop monitor retrieve or record telephone conversation or other sound activities...

Page 43: ...cking messages Caller ID Caller ID allows a display terminal to show an incoming caller s telephone number called the Directory Number or DN and optional name The Caller ID information is available as...

Page 44: ...ce can be changed in system programming or via a Service Code normally 777 There are 15 available Classes of Service Clock Calendar Display The system uses Clock Calendar Display for Using the Dayligh...

Page 45: ...verride lets a user temporarily bypass the Code Restriction for an extension This helps a user that must place an important call that Code Restriction normally prevents For example you could set up Co...

Page 46: ...ce Call Privacy Release Voice Call Conference lets an extension user in the same work area join in a trunk Conference To initiate a Voice Call Conference an extension user presses the Meet Me Conferen...

Page 47: ...r the outside service answers the user can dial digits for whatever options the services allow Without Continued Dialing the system Toll Restriction cuts off the call after a specific number of dialed...

Page 48: ...the trunk directly by pressing a line key or dialing 9 and the trunk number the system drops the trunk if dial tone does not occur If the user accesses the trunk via a Trunk Group by dialing a trunk...

Page 49: ...ialing of system extensions DID provides DID Dialed Number Translation Flexible DID Service Compatibility DID Intercept DID Camp On There are 20 DID Translation tables that can be divided between 2000...

Page 50: ...m trunk uses a selected feature or dials a system extension DISA calls ring system extensions like other outside calls If an extension has a line key for the DISA trunk the call rings that key If the...

Page 51: ...multiline terminal user to select a co worker or outside caller from a list of names rather than dialing the telephone number There are four types of Directory Dialing SPD Speed Dials EXT Co worker s...

Page 52: ...button like a door bell The Door Box then sends chime tones to all extensions programmed to receive chimes To answer the chime the called extension user lifts the handset This lets the extension user...

Page 53: ...ers for compatibility with the connected Telco or PBX Flexible System Numbering Flexible System Numbering lets you reassign the system port to extension assignments This allows an employee to retain t...

Page 54: ...the extension priority in the Pickup Group With Group Call Pickup a user can intercept the following calls A call ringing the user s own pickup group A call ringing another pickup group when the user...

Page 55: ...ee Answerback Forced Intercom Ringing Handsfree Answerback permits an extension user to respond to a voice announced Intercom call by speaking toward the telephone without lifting the handset Like Han...

Page 56: ...e an Intercom call on Hold The Intercom call on Hold does not indicate at any other extension Hot Key Pad The Hot Key Pad feature allows the user to place a call without lifting the handset or pressin...

Page 57: ...Internal External Refer to Ringdown Extension Internal External on page 2 37 In addition the Hotline key shows the status of the partner extension There are 512 internal Hotline extensions available H...

Page 58: ...ensions using a variety of multiline terminals These telephones have the same look and functionality of typical multiline telephones but they are connected to the CCPU via IP rather than by a hardwire...

Page 59: ...ket Based Multimedia Communication Systems The UNIVERGE SV8100 can use H 323 to connect to another UNIVERGE SV8100 system or a third party product The feature set is limited When using H 323 it is not...

Page 60: ...els provide two voice path connections Caller ID is usually a standard feature on ISDN BRI provided trunks Caller ID indication displays the calling party telephone number on the LCD of the multiline...

Page 61: ...he handset answers either the ringing call for Ringing Line Preference or seizes an idle line for Idle Line Preference The idle line can provide either Intercom or trunk dial tone see Outgoing Line Pr...

Page 62: ...n reset only the slot in question The SV8100 Maintenance manual contains a number of flow charts to help technicians diagnose and resolve problems that may arise during and after the installation of t...

Page 63: ...ng up When a user enters a Memo Dial number the dialed digits do not output over the trunk Dialing Memo Dial digits does not interfere with a call in progress Message Waiting An extension user can lea...

Page 64: ...external telephone preferably a mobile phone linked to the UNIVERGE SV8100 via a Proxy Port to operate as an internal single line telephone extension The extension sends DTMF signals to the system al...

Page 65: ...ailable When using the Name Storing feature the system now provides additional characters which can be used These characters are available with any option that allows Name Storing Speed Dial System Gr...

Page 66: ...he company then one of keys 2 5 to ring the employee to whom they want to speak An extension user or system administrator can optionally store a Flash command under a One Touch key This is helpful for...

Page 67: ...ents to other multiline terminal users When a user makes a Zone Paging announcement the announcement broadcasts to all idle extensions in the zone dialed With All Call Paging the announcement broadcas...

Page 68: ...Personal Park feature is enhanced by using a Programmable Function Key or service code 3 digit or 1 digit to place a call in Personal Park This option is available for multiline terminals single line...

Page 69: ...are for them Additionally the user has their own trunk for placing calls that is not available to others in the system Programmable Function Keys Each multiline terminal has Programmable Function Key...

Page 70: ...to try the number again hoping it goes through Repeat Redial automatically retries it until the called party answers the number of retries is based on system programming Resident System Program When p...

Page 71: ...lows Ring Groups 1 100 In Skin Voice Mail 102 Centralized Voice Mail 103 If an extension has a line key for the trunk Ring Group calls ring the line key If the extension does not have a line key the t...

Page 72: ...a user goes off hook and dials a service code and the extension number of the monitoring telephone At the monitoring station a user goes off hook and dials a service code and the extension number of t...

Page 73: ...t have multiline terminals with Secretary Call buzzer keys When a user presses their buzzer key the system alerts the called extension by sending a splash tone and flashing the called extension buzzer...

Page 74: ...ming back from vacation The system allows all telephones to use the Selectable Display Messaging feature at the same time All telephones can use Selectable Display Messaging at one time The default me...

Page 75: ...r may be restricted due to system power requirements When installing single line telephones you must have A port on an LCA blade for each single line telephone installed If you have DTMF sets at least...

Page 76: ...r later handling Using computer telephony integration CTI the IVR can hand off a call to someone that can view data related to the caller at a display The programmable IVR uses open database connectiv...

Page 77: ...lso customize the point at which the built in speakerphone switches from transmit to receive a boon for noisy environments The display telephones also have a contrast control for the LCD display Speed...

Page 78: ...ber under the other e g 201 The DSS Console user can press the first key to call the company wait for the Automated Attendant to answer then press the second key to call the client extension 400 The D...

Page 79: ...affic management easier SMDR provides the following options Abandoned Call Reporting Blocked Call Reporting Customized Date Format Transferred Call Tracking Data Call Tracking Digit Counting Digit Mas...

Page 80: ...r via the Desktop Application o DNIS display for incoming calls to the Desktop station when DNIS information is provided o IP Softphone support for wide band codec G 722 o Notification by Windows toas...

Page 81: ...arrives or when the user moves the mouse to the edge of the display In addition to quick access to these SV8100 features the Assistant provides a call log for easy viewing of recent received missed o...

Page 82: ...e SV8100 CD CP00 The PC Attendant application also includes a supporting application called Quick Message By installing the Quick Message client on individual PCs the attendant is able to quickly send...

Page 83: ...s the Univerge SV8100 and SV8300 systems All user ports can support up to Gigabit Ethernet and may support the primary Layer 2 protocols also with an emphasis on QoS features such as 802 1p and Diffse...

Page 84: ...ementation 802 1Q based VLANs enable segmentation of networks for improved performance and security VLAN Port Based and 802 1Q Tag based VLANS Management VLAN Automatic configuration of VLANs across m...

Page 85: ...an extension user to have two telephones with one telephone number For example extension 205 the master telephone sets Tandem Ringing with extension 206 When extension 205 receives an incoming call bo...

Page 86: ...CD CP00 provides two blocks of 32 conference circuits allowing each block to have any number of conferences with any number of internal or external parties conferenced as long as the total number of...

Page 87: ...nversation a programmed time If the user enters the Disconnect service code the call is disconnected immediately TAPI Compatibility The system has Telephony Applications Programming Interface TAPI com...

Page 88: ...amming The system outputs this data to the PC for the total period Transfer Transfer permits an extension user to send an active Intercom or outside call to any other extension in the system With Tran...

Page 89: ...l on hold Trunk Group Routing Trunk Group Routing sets outbound call routing options for users that dial the Trunk Group Routing code 9 for trunk calls Trunk Group Routing routes calls in the order sp...

Page 90: ...ng SBR and blending customer contacts using Telephone Email Web Callback Web Chat and Voicemail UCB provides much more than a conventional Automatic Call Distribution system UCB is licensed according...

Page 91: ...t pilot number The caller would not have to know any Sales department extension numbers User Log Out Log In An extension user can log out and log in to a UCD Department group By logging out the user r...

Page 92: ...ing up the VRS The system prevents hunting to a UCD Department group extension if it is Busy on a call In Do Not Disturb Call Forwarded Logged Out Uniform Numbering Network Uniform Numbering Network a...

Page 93: ...unk group to access and any modified dialed data if required Universal Slots The UNIVERGE SV8100 has six universal slots and up to four cabinets can be installed The system uses the same chassis for t...

Page 94: ...ail Park and Page VM8000 InMail Park and Page can automatically Park a call at an extension and Page the user with a prerecorded Paging Message announcing the parked call The called extension user can...

Page 95: ...Automated Attendant go directly to the subscriber s mailbox The extension does not ring for Automated Attendant calls The caller hears the mailbox greeting and can leave a message but unlike Park and...

Page 96: ...Line Keys Voice Mail Message Indication on Line Keys indicates a new Voice Mail message on Line Keys or DSS BLF keys Voice Over Voice Over lets a user interrupt a busy station user that is on another...

Page 97: ...t Operator Assistance answers incoming calls plays a greeting to the caller and then lets the caller directly dial a system extension ACD Messages provides announcement and overflow messages for ACD g...

Page 98: ...ress the VOLUME s or VOLUME t to adjust the volume level for the active feature e g outside call ICM ICM ringing or paging Press these keys when the telephone is idle to adjust the contrast level of t...

Page 99: ...ide the freedom and convenience of a wireless telephone but also allow access to features provided by the UNIVERGE SV8100 system The number of Wireless DECT SIP handsets supported by the UNIVERGE SV81...

Page 100: ...hours Directory Phone book multiple numbers per contact Personal phone book Display colour Graphic TFT display 160 X 128 pixels 262k Illuminated display Incoming calls and messages Headset Headset su...

Page 101: ...data Storage of local user data personal phone book caller log caller filter and calender entries Memory card the storage capacity can be doubled by adding a memory card The memory card also contains...

Page 102: ...Issue 2 00 UNIVERGE SV8100 2 68 Features THIS PAGE INTENTIONALLY LEFT BLANK...

Page 103: ...ing chassis chassis with CPU blade and the ability to expand the system using expansion blades depending on system configuration The CHS2U GW is a standalone 9 5 chassis providing three universal slot...

Page 104: ...hassis CHS2U 19 Chassis 1 1 4 Virtual slot in NetLink is limited to maximum of 240 Expansion PZ BS10 3 jack Expansion Board for Controlling Chassis 0 1 0 1 PZ BS11 1 jack Expansion Board for Expansion...

Page 105: ...s with CPU 19 Chassis without CPU 19 Chassis x4 Comments Number of Slot s for Interface Package 3 Slots 5 Slots 6 Slots 23 Slots Common Control Blades CD CP00 1 1 0 1 PZ 32IPLA 32 port VoIP Daughter B...

Page 106: ...ME50 card fitted An optional PZ 4COTE or PZ 2BRIA can be installed Trunk Blades CD 2BRIA 2 Basic Rate Interface 2 5 6 23 PZ 2BRIA 2 Basic Rate Interface Daughter Board 2 5 6 23 CD 4COTA 4 Loop Start T...

Page 107: ...e 2 5 6 23 CD ETIA Switching Hub with Power over Ethernet 2 3 3 12 CD RTB Router 1 1 2 7 CD VM00 Voice Mail and Server 1 1 1 1 Maximum of One per system Table 3 2 SV8100 Maximum System Capacities Blad...

Page 108: ...mum Number of Packages Installed Refer to Table 3 6 Terminal Power Factor below for the Terminal Adapter power chart CD 16DLCA 16 Digital Station Interface CD 2BRIA 2 Basic Rate Interface 4 Does not a...

Page 109: ...12 CD PVAA 1 2 5 6 23 CD RTB 2 1 2 2 8 Table 3 6 Terminal Power Factor Terminal Power Factor 19 inch Metal Chassis with Fan 80 9 5 inch Plastic Chassis without Fan 64 Item Power Factor DTL 24D 1 TEL...

Page 110: ...290mA 7 0W 111mA 5 3W 192mA 4 6W ITL 32D 1 TEL Class 2 130mA 6 2W 235mA 5 6W 90mA 4 3W 153mA 3 7W ITL 8LD 1 TEL Class 2 130mA 6 2W 235mA 5 6W 81mA 3 9W 137mA 3 3W ITL 24D 1 TEL Class 2 130mA 6 2W 235...

Page 111: ...RGE SV8100 Issue 2 00 Configuration Guide 3 9 Table 3 8 IEEE802 af Class Specifications IEEE802 3af Minimum Maximum Class 4 Class 3 6 49W 12 95W Class 2 3 84W 6 49W Class 1 0 44W 3 84W Class 0 0 44W 1...

Page 112: ...Issue 2 00 UNIVERGE SV8100 3 10 Equipment THIS PAGE INTENTIONALLY LEFT BLANK...

Page 113: ...Coder Conversion The CD CP00 uses a 32 bit industrial standard CPU and associated memories to control the system The CD CP00 bus is connected to the backplane of the chassis and provides control for o...

Page 114: ...ugs Universal slots maximize flexibility by allowing installation of any blade in any interface slot except slot 1 of chassis 1 reserved for the CD CP00 Full use of each chassis before adding another...

Page 115: ...ne Paging Groups or various timers Battery Backup The battery on the CD CP00 retains the Clock Calendar and Last Number Redial LNR buffers for each station when the CD CP00 encounters a power loss Whe...

Page 116: ...he CD CP00 with this switch OFF can be removed or installed with the system power on The combination of status indication and blade replacement with power on allows the maintenance technician to repla...

Page 117: ...aximum of three expansion chassis Expansion chassis can be stacked vertically on the base chassis to expand the system capacity to 368 ports By linking two UNIVERGE SV8100 systems via IP connection th...

Page 118: ...able 5 1 SV8100 Maximum System Capacities Chassis shows the maximum number of chassis and related equipment that can be installed in a system Figure 5 2 UNIVERGE SV8100 CHS2U GW Chassis 3 Slots 48 Por...

Page 119: ...t be allocated for dial tone detection Expansion PZ BS10 3 jack Expansion Board for Controlling Chassis 0 1 0 1 PZ BS11 1 jack Expansion Board for Expansion Chassis 0 0 1 3 Battery CHS LARGE BATT BOX...

Page 120: ...t VoIP Daughter Board 1 1 0 1 This unit provides 64 VOIP Gateway channels PZ 128IPLA 128 port VoIP Daughter Board 1 1 0 1 This unit provides 128 VOIP Gateway channels PZ ME50 Memory Expansion Daughter...

Page 121: ...Interface 2 5 6 23 PZ 2BRIA 2 Basic Rate Interface Daughter Board 2 5 6 23 CD 4COTA 4 Loop Start Trunk 2 5 6 23 PZ 4COTE 4 Loop Start Trunk Daughter Board 2 5 6 23 CD 4DIOPB 4 DID OPX 2 5 6 23 When in...

Page 122: ...CD RTB Router 1 1 2 7 CD VM00 Voice Mail and Server 1 1 1 1 Maximum of One per system Table 5 2 SV8100 Maximum System Capacities Blades Continued Hardware 9 5 Chassis 19 Chassis with CPU 19 Chassis wi...

Page 123: ...ng normal operation the RUN LED will be flashing and the remaining LEDs will be off 700x700 Time Division Multiplex Switch TDM Switch Digital Phase Locked Loop DPLL SECTION 3 CABLING REQUIREMENTS AND...

Page 124: ...le 5 7 Cable Connection Between the Analog Port and the Single Line Equipment Table 5 8 Cabling Requirements Figure 5 3 Connecting the DLC Using Twisted 2 Pair Cable Table 5 4 DT300 Series Loop Resist...

Page 125: ...ITL 8LD 1 BK TEL ITL 8LD 1 WH TEL Cat 5 Cat 6 Ethernet 328 1 ft 100m ITL 12D 1 BK TEL ITL 12D 1 WH TEL Cat 5 Cat 6 Ethernet 328 1 ft 100m ITL 12PA 1 BK TEL Cat 5 Cat 6 Ethernet 328 1 ft 100m ITL 24D 1...

Page 126: ...0 1400 107 2000 2000 DTH 16 1 TEL DTR 16 1 TEL 35 660 1320 107 2000 2000 DTH 16D 1 TEL DTR 16D 1 TEL 35 660 1320 107 2000 2000 DTH 32D 1 TEL DTR 32D 1 TEL 26 500 1000 107 2000 2000 DTH 16LD 1 TEL 37 7...

Page 127: ...63Hz Rated frequency 50 60Hz Phase and Wire Single Phase 2 Line PE Type Grounding Requirements No 14 AWG copper wire Feeding Voltage Dterm OPX DID 48V SLT 25mA 28V With input voltage of 230 VAC and wi...

Page 128: ...10 90 RH non condensing Recommended Long Term Humidity 10 90 RH Blades Daughter Boards PZ BS10 PZ BS11 PZ VM21 PZ ME50 CD 8DLCA CD 16DLCA PZ 8DLCB Operating Temperature 32 F 104oF 0oC 40oC Recommended...

Page 129: ...ing Temperature 32 F 104 F 0o C 40o C Recommended Long Term Temperature 4 F 167o F 40o C 75o C Operating Humidity 20 95 RH non condensing Recommended Long Term Humidity 10 95 RH 5 2 Outside Line Types...

Page 130: ...r one communications medium The specifications that the UNIVERGE SV8100 system uses for switching clock data bus and timeframe are shown below TDM Switching PCM A Law TDM Clock 2 048 MHz TDM Data Bus...

Page 131: ...ent 250 mA Single Line Telephone Standard 2500 Set 500 type network Nominal Current 25 mA Ring Signal 56 Vac RMS 20 Hz SLTII 1 U ADP Standard 2500 Set 500 type network Nominal Current 30 mA Ring Signa...

Page 132: ...em Pulse Rate 10 0 5 pps 20 1 0 pps Percent Break 60 1 5 Interdigit Interval 0 pps 20 pps 770 ms 830 ms 5 4 2 Dual Tone Multifrequency DTMF Address Signaling DTMF signaling includes push button or Tou...

Page 133: ...U10 ADP Door Lock Release or General Purpose Relay via PGD 2 U10 ADP Printer for SMDR by LAN PC by LAN 5 4 4 Music Source for Music on Hold via Chassis Auxiliary Input 0 6V PPS Signal Level Input Impe...

Page 134: ...wer failure the system can be backed up using the CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the CHS LARGE BATT SETs for a backup time ranging from 45 180 minutes The CHS2U GW can be...

Page 135: ...in 3 mm 2 56 in 65 mm 1 22 in 31 mm CD LTA 6 70 oz 0 19 kg 0 98 in 25 mm 5 71 in 145 mm 7 09 in 180 mm MGN U10 ETU 14 6 oz 0 41 kg 1 89 in 48 mm 11 47 in 290 mm 8 46 in 214 mm CHS LARGE BATT BOX 352...

Page 136: ...kg 0 60 in 15 mm 9 45 in 240 mm 7 68 in 195 mm CD 8LCA 6 46 oz 0 183 kg 0 98 in 25 mm 9 45 in 240 mm 7 68 in 195 mm PZ 8LCE 3 70 oz 0 105 kg 0 60 in 15 mm 9 45 in 240 mm 5 12 in 130 mm CD 2BRIA 5 99...

Page 137: ...n 133 mm 16 93 in 430 mm 14 3 in 363 mm CHS2U JOINT BRACKET KIT 7 06 oz 0 2 kg 0 19 in 3 mm 5 91 in 150 mm 1 7 in 43 mm CHS2U BATT MTG KIT 6 Slot 106 oz 3 0 kg 2 95 in 75 mm 4 45 in 113 mm 4 13 in 105...

Page 138: ...mm ITL 32D 1 BK TEL ITL 32D 1 WH TEL 45 6 oz 1 3 kg 4 41 in 112 mm 8 1 in 205 8 mm 10 16 in 258 mm ITL 320C 1 BK TEL 56 44 oz 1 6 kg 4 41 in 112 mm 8 94 in 227 mm 9 84 in 250 mm Optional 8LK L BK UNI...

Page 139: ...efer to Table 5 12 Multiline Terminal LED Flash Pattern PSA L BK UNIT PSA L WH UNIT 10 58 oz 0 3 kg 3 15 in 80 mm 2 91 in 74 mm 8 8 in 223 mm GBA L UNIT 23 99 oz 0 68 kg 5 9 in 150 mm 7 05 in 179 mm 6...

Page 140: ...l Tone 440 Continuous Reorder Tone 480 620 120 IPM Service Set Tone 440 Continuous Special Dial Tone 440 240 IPM Tone Burst 1 Tone 440 Continuous Tone Burst 2 Tone 620 Continuous Tie DID Ringback Tone...

Page 141: ...Internal Call Incoming Outside Call Message from Attendant Voice Mail Message Red Green Green Red Speaker ON System Data Entry Red Red Answer Incoming Trunk Exclusive Hold User Ringing Line Preferenc...

Page 142: ...Issue 2 00 UNIVERGE SV8100 5 26 Hardware Specifications THIS PAGE INTENTIONALLY LEFT BLANK...

Page 143: ...CA value for a single CPU is theoretical 5120 This value is the value without any Busy Lamp Fields BLF TAPI OAI CTI load but does include SMDR ii End User Experience when traffic exceeds the boundarie...

Page 144: ...CONSIDERATIONS 2 1 Traffic performance To be detailed work in progress 2 2 Trunks a If all the trunks are located at the central system i Central system could be overloaded because of BHCA exceeded w...

Page 145: ...ying repeatedly 2 7 Number of Nodes a In practice max 16 nodes are recommended This due to the practical considerations described in this chapter SECTION 3 SV8100 FEATURENET CONSIDERATIONS 3 1 Trunks...

Page 146: ...be difficult because of numbering plan limitations d All of the data must be duplicated each time there is a change for example if a toll restriction number is added it must be added to 10 nodes Not...

Page 147: ...cult to administer copy prompts when one is update etc 3 8 Extensions a There may not be enough DTMF resources 96 maximum if some nodes have a lot of SLTs on site End user could experience no dial ton...

Page 148: ...Hotel a Hotel operation is not recommended in a AspireNet configuration 3 11 Number of Nodes a In practice a maximum of 16 nodes are recommended This due to the practical considerations described in...

Page 149: ......

Page 150: ...CONFIGURATION GUIDE NEC Unified Solutions Issue 2 00...

Reviews: