FP85-104 S1

PCPro Setup Manual

NWA-041691-001

ISSUE 1.0

Summary of Contents for SV8500

Page 1: ...FP85 104 S1 PCPro Setup Manual NWA 041691 001 ISSUE 1 0...

Page 2: ...this document for use by its employees and customers The information contained herein is the property of NEC Infrontia Corporation and shall not be reproduced without prior written approval from NEC I...

Page 3: ...y or a serious system fault ATTENTION Incorrect use of the equipment may limit the system performance or cause the system to fail The telephone system can only be used in NEC designated countries If a...

Page 4: ...in this state might cause a fire an electrical shock or a system failure Do not touch the internal parts of the main power source to disassemble or configure it This action may cause a fire an electr...

Page 5: ...ock or a system failure If this occurs turn off the power and contact the dealer Be careful when using any peripheral equipment s Liquid Crystal Display LCD If the liquid leaks it can be harmful to th...

Page 6: ...ck to occur If lightning causes a fault contact the dealer Provide the appropriate temperature humidity and ventilation on an around the clock basis For example at a height that is one meter 3 28 feet...

Page 7: ...fe expectancy drops to approximately one year Perform periodic diagnostic tests and maintenance procedures on the emergency battery and its terminals to ensure their readiness If there is a power fail...

Page 8: ...s television sets and two way radios Locations that receive illegal electric waves The life expectancies of the PBX and the main power source will be shortened if placed in a location that is affected...

Page 9: ...RNING Consider measures to deal with disasters such as fires floods and earthquakes and to ensure the safety of the staff Regularly clean the room or rooms where the switching equipment resides Do not...

Page 10: ...PE from the PBX through the Rectifier The Frame Ground FE from the MDF The AC service outlets with AC 100 V plug outlets for the MAT printer modems and any measurement devices such as a protocol analy...

Page 11: ...te 3 In regard to China market NEAX2000 IPS INTERNET PROTOCOL SERVER has not been released but NEAX2000 is released TERMS USED IN THIS MANUAL SYSTEM NAMES SV8500 the system UNIVERGE SV8500 SV7000 the...

Page 12: ...rm 75 Dterm Series i DT300 Series DT310 DT330 IP Station IP terminal IP Enabled Dterm Dterm Series E Dterm 75 with IP adapter Note 4 Dterm Series i with IP adapter Note 4 DtermIP INASET Note 4 DtermIP...

Page 13: ...SCA 30PRIA MG PRI Box MG 30PRIA MG PRI MG PRA MG T1 SIP MG T1 SIP Card SCA 24DTIA MG BRI MG BRI Card SCA 2BRIA MG BRI Box MG 2BRIA MG BRI MG SIP MG SIP16 MG SIP16 Card SCA 16SIPMGA MG SIP16 Box MG 16...

Page 14: ...TERMS 4 General Terms Automatic Number Identification ANI on this manual is a term equivalent to Calling Line Identification CLI in Australia...

Page 15: ...perating environment of PC 14 2 2 Operating Conditions 16 3 Conditions for Operating PCPro 16 CHAPTER 3 Setting Up PCPro 17 1 Installing PCPro 17 2 Launching PCPro 18 3 Connecting PCPro to the Telepho...

Page 16: ...45 1 Connection Account Setting 45 2 User Account Setting 48 3 Change Password 50 4 Login Grade Setting 51 CHAPTER 6 Command Operation 53 1 Commands without a Menu Bar 53 2 Commands with a Menu Bar 5...

Page 17: ...ze chapters 2 through 8 Chapter 2 PCPro Overview Provides introductory information about PCPro and proceeds to describe its system configuration operat ing environment working conditions and more Chap...

Page 18: ...2 CHAPTER 1 Introduction 3 About Release Information The table below shows the relationship between IPX SV7000 and SV8500 for the release information IPX SV7000 SV8500 R25 S1 R26 S2 R27 S3...

Page 19: ...istration Destination of IP Devices Stations 4 2 TP and SP for System Changeover In dual configuration each processor may stay in active ACT or stand by STBY state ACT side processors handle each oper...

Page 20: ...of DRS SIP server is however same as that of Telephony Server Therefore IP ad dress of DRS SIP server is also as the table above Note 1 Telephony Server has two parts of processors on its CPU TP and S...

Page 21: ...y Protocol mode uses LAN1 as the registration destination while uses LAN2 as the signaling control port LAN interface for the signaling control port however can be changed to LAN1 by ADTM command Note...

Page 22: ...sys tem is in sigle configuration or dual configuration IP address ACT is basically assigned to the devices terminals as Telephony Server address Note When the system is in dual configuration IP addr...

Page 23: ...ation Protocol Port No IP Address Registration by Proprietary Protocol UDP 3456 ACT Registration by SIP UDP 5060 ACT System 0 System 1 Internal PHI Note 1 UDP 64000 ACT NMS TCP 60060 Receiving Health...

Page 24: ...uration or dual configuration IP address ACT is basically assigned to the devices as Telephony Server address EMA MAIN PWR SYS ALM SYS 1 MB SUB SYS LOCK SYS SEL PFT LINK OPE ALM INIT PBI No SYS 0 1 2...

Page 25: ...n Protocol Port No IP Address PCPro TCP 60000 ACT CCIS Cluster TCP 60001 SMDR TCP 60010 MCI TCP 60020 OAI TCP 60030 MIS TCP 60040 PMS TCP 60050 CS Report TCP 60080 MCC TCP 60190 FCCS Cluster TCP 60210...

Page 26: ...this manual the range blocked in dotted blue is called SV8500 server IOC DTI CCH CCH DTI DCH PRT BRT ATI ELC ILC COT COT COT DID ODT EMT LDT LC MODEM MUX TSW MDF BWT DOD DIT DID ATT Desk Console NCU...

Page 27: ...nnel Handler DID Direct Inward Dialing DIT Direct In Termination DLC Digital Line Circuit DOD Direct Outward Dialing DTI Digital Interface ELC Electronic Line Circuit EMT E M Trunk IOC Input Output Co...

Page 28: ...12 CHAPTER 1 Introduction This page is for your notes...

Page 29: ...that installs and services the system PCPro registers the accommodated station and assigns the data for an outgoing incoming call by using the commands The general configuration of system maintenance...

Page 30: ...on with telephony server Table 2 1 Common Operating Environment Item Specification Hard disk PCPro and PCPro Tools System Drive 1 0GB of free disk space minimum Installing Drive Note 1 4 0GB of free d...

Page 31: ...t supported Install the latest release of service pack and security patches on the OS used 64 bit CPU is not supported Table 2 2 OS Specific Operating Environments Item Specification Microsoft Windows...

Page 32: ...other application must not be launched 2 Disable the power management of PC 3 A maximum of four PCPro are available for serial connection in the same system However same com mand cannot be used on mu...

Page 33: ...button and proceed as directed by onscreen guidance Note If you are running Windows Vista when the Install PCPro is selected it displays a dialog box Click Al low to continue with the installation No...

Page 34: ...o launch PCPro follow these steps STEP 1 Launch PCPro in any of the following operations Double click the PCPro icon in the Desktop Choose Start All Programs SV8500 PCPro SV8500 PCPro in Windows OS Th...

Page 35: ...ection Serial Dial up Connection TCP IP Connection 3 1 Serial Direct Connection 3 1 1 Connection method STEP 1 Connect PCPro directly to IOC by using RS 232C serial port 3 1 2 Hardware requirements Cu...

Page 36: ...PCPro to IOC via modem by using RS 232C serial port Note Before setting the Connection Account Setting set the following setting Modem Setting on IOC side Modem Setting on PCPro side STEP 2 Connect t...

Page 37: ...dem in the marketplace compliant to the following specification Modem supporting AT commands Synchronous Asynchronous communica tion Supporting MNP Duplex 2400 RS 232C CA 3 Cable SV 4PORT CA A Cable C...

Page 38: ...CPro Case 1 Case 2 In the case of Network PC LAN Connection Connect PCPro and the system to the existing LAN PCPro HUB 10 BASE T Straight Cable PCPro 10 BASE T Straight Cable HUB PCPro PC PC Server 10...

Page 39: ...2 Display the Hyper Terminal window Click start Programs Accessories Communications Hyper Terminal STEP 3 Set the connection 1 Enter a name and an icon for the connection and click the OK button Desc...

Page 40: ...The following parameter are not available Country region Area code Phone number STEP 4 Set the COM1 port Set as the following parameter Parameter Value Bits per second 4800 bps Data bits 8 Parity Set...

Page 41: ...25 CHAPTER 3 Setting Up PCPro STEP 5 On the Hyper Terminal window set as follows referring to the manual of modem to be used...

Page 42: ...em In the case of IPX system use IPX 2PORT CA A cable instead of SV 4PORT CA A cable STEP 8 Exit the hyper terminal Now the modem setting on IOC side has been complete 3 5 Modem Setting on PCPro side...

Page 43: ...ing Up PCPro STEP 2 Select a modem from the Modems tab and click the Properties button The installed modem is displayed STEP 3 Select Modem tab and select the same value as set for the I O baud rate o...

Page 44: ...28 CHAPTER 3 Setting Up PCPro STEP 4 Back on the Phone and Modem options window select a lacation from Dialing Rules tab and click the Edit button XXXXX Modem Properties...

Page 45: ...29 CHAPTER 3 Setting Up PCPro...

Page 46: ...Select General tab on the Edit Location window and set the dialing rules Note Set the dialing rules according to your using environment STEP 6 Exit the Phone and Modem Options window Now the modem se...

Page 47: ...fer to Connec tion Account Setting STEP 3 Select a connection account The default connection account is not registered Therefore create a new connection account at the first time connection For instru...

Page 48: ...u if it is OK to disconnect from the system The commands being executed will exit automatically Also If alarms and traffic data are being collect ed it will stop However in the following cases they wi...

Page 49: ...ing the system Login Grade Setting Set an availability on the user account for executing each command The user account with this setting is restricted from using commands 7 Exiting PCPro To exit PCPro...

Page 50: ...ll not exit automatically Command without a Menu Bar While the communication link with the system is being established While displaying a dialog such as error messages Command with a Menu Bar They wil...

Page 51: ...ions of its components 1 PCPro Window Component Names and Functions The PCPro main window is organized into the items listed in the table below System data set on the Telephony Server can be configure...

Page 52: ...bar Displays the status of PCPro operation and that of connection with the Tele phony Server page 43 4 Submenu Displays the submenu associated with the mode selector tab being selected page 40 5 Mode...

Page 53: ...ys the Connect screen for establishing a communication link with the Telephony Server Disconnect Displays the Disconnect screen for clearing clear a communication link with the Telephony Server Connec...

Page 54: ...displayed active in the foreground 6 Log All Logs Management Display the Log File Selection screen to man age the command execution logs Operation Log Limitation Display the Operation Log Limitation s...

Page 55: ...Setting screen for creating and verifying a connection ac count 5 User User Account Set ting Display the User Account Setting screen to cre ate the user account for the system being con nected 6 Chan...

Page 56: ...of the command you want to execute 2 Execute button Click to execute the command 3 Submenu display Displays mode specific submenus Click a menu choice to open a setup screen in the work window For mo...

Page 57: ...earch Keyword entry field Type the part of the command name or function you want to search for 2 Search button Click to launch a search 3 Search Result List As a search result commnad name and the for...

Page 58: ...d from the submenus Note Only the command that does not have a menu bar can be displayed in this work window The other com mands that has a menu bar is displayed in another window For the detail see C...

Page 59: ...tem Data Mode page 40 2 Search tab Switches the submenu view to Search Mode page 41 No Item Description 1 Connection Account Displays the connection account of the Telephony Server with which PCPro ha...

Page 60: ...ally collects the accumulated alarms MJ MN SUP 3 Collect New Traf fic Change ON OFF for the automatic traffic collec tion that automatically collects the accumulated traffic data 4 Abort Data Collec t...

Page 61: ...connection account used to establish a communication link between the Telephony Server and PCPro follow these steps STEP 1 In the PCPro window select one of the following On the Main Menu click Syste...

Page 62: ...fusion group number of the system from 0 4 default 0 6 FPC Enter the fusion point number of the system from 0 253 7 Connection Type Select the connection type with the system from the following TCP I...

Page 63: ...o STEP 2 Click the Setup button after editing the item 4 8 The registered connection account is added to the connection account list STEP 3 Click Close button to close the connection account setting s...

Page 64: ...ption 1 User Account List Displays a list of user accounts registered on the system being connected 2 Add button Click to add an additional user account The item 4 8 are initialized and a new data can...

Page 65: ...e Setup button after editing the item 4 8 The registered user ID is added to the user account list STEP 3 Click Close button in the User Account Setting screen No Item Description 6 Password Enter the...

Page 66: ...pe the password you want to register in the New Password field Note 1 The entered characters are displayed as The new password has been registered No Item Description 1 Current Password Enter the pass...

Page 67: ...tting Set the login grade for the system connected with PCPro STEP 1 Open the Login Grade Setting screen in any of the following operations Choose User Login Grade Setting on the menu bar Double click...

Page 68: ...n grade and click the Setup button exist is displayed on the Data column of the login grade being selected from the login grade list STEP 3 Click Close button in the Login Grade Setting screen The log...

Page 69: ...and Operation CHAPTER 6 Command Operation This chapter describes how to operate the commands to execute on PCPro 1 Commands without a Menu Bar Commands without a man bar operate in the work window of...

Page 70: ...n turns every time the Next button is pressed 6 Previous button The previous one of the keyword searched in 5 is focused is searched and focused in turns every time the Previous button is pressed Key...

Page 71: ...ew the Log Management screen that displays the operating logs 3 Help MAT Help Display the details of each parameter Keyboard Help Display the function of the short cut key Key Description F1 Call up t...

Page 72: ...56 CHAPTER 6 Command Operation This page is for your notes...

Page 73: ...Windows operating system Note Microsoft NET Framework 2 0 or 3 0 needs to be installed on the PC for using PCPro Tools When install ing the PCPro Tools it will be installed automatically if not instal...

Page 74: ...58 CHAPTER 7 PCPro Tools 3 PCPro Tools Window Layout 1 2 3 4 5 6...

Page 75: ...s a program required to start up PCPro Tools A program is written into Drive A and an office data is writ ten into Drive B Program Uploads downloads a program to from CF card Office Data Uploads downl...

Page 76: ...is not displayed when Initial Installation Collect Log or System Conrol is selected Note Only the drive B and C can be selected when Office Data is selected System Side No Item Description 5 System 0...

Page 77: ...Start Control Panel in Windows OS The Control Panel dialog box is displayed STEP 2 Double click the Add or Remove Programs icon STEP 3 Select SV8500 PCPro in the Add Remove Programs dialog box and cli...

Page 78: ...may be displayed on the following menu and the descriptions No Item Description 1 Error Message Dialog Displayed when an error occurred while operating the PCPro 2 Error Provider Icon Displayed beside...

Page 79: ...ndow Specified Connection Account is already connected with this terminal Displayed when trying to connect multiple PCPro launched on the same terminal to the system Connection towards the system has...

Page 80: ...in any parameter restricting the characters Registered Displayed when already registered characters are entered in the Account Name parameter Out of range Displayed when an out of range value is ente...

Page 81: ...ter Error Message Description Invalid data exists Displayed when pressing the Change button to set an invalid data Failed to change the Password Displayed when it failed to change the password Invalid...

Page 82: ...hen it failed to load the login grade data Executable Command has not been selected Displayed when pressing the Setup button while the executable command not selected Data assignment failed Displayed...

Page 83: ...Printed in Japan 0807 010...