background image

USER’S GUIDE

Smart Touchless Forehead Thermometer

Model: MBP70SN

Please read this instruction manual before use

Summary of Contents for MBP70SN

Page 1: ...USER S GUIDE Smart Touchless Forehead Thermometer Model MBP70SN Please read this instruction manual before use ...

Page 2: ...on sterile reusable clinical thermometer intended for the intermittent determination of human body temperature in touch and no touch mode using the center of the forehead as the measurement site for people of all ages The operator can measure and change battery under normal circumstances and maintain the device and its accessories in accordance with the user manual Operators can take others as wel...

Page 3: ...torolastore com On the Web www motorolastore com support This User s Guide has all the information you need to make the most out of your product Please read the Safety Instructions on page 7 before you install the unit Inside the Box 1 x Thermometer 2 x AAA Batteries 1 x Quick Start Guide ...

Page 4: ...e user profile a Press this button to view the memory data Press Temperature measuring button to exit memory data b Press and hold for 2 seconds to select the desired user profile Mode button select either body temperature or liquid temperature readings By pressing and together you can switch between taking body temperature and object liquid temperature measurement To switch between Celsius C and ...

Page 5: ...user profiles 2 Memory symbol 3 Bluetooth symbol lights up when thermometer is connected to the smartphone 4 Low battery symbol 5 Forehead temperature symbol 6 Object Liquid temperature symbol 7 Temperature display C F ...

Page 6: ...RE OBJECT LIQUID TEMPERATURE 23 11 CHECK THE MEMORY 24 11 1 SELECTING THE USER PROFILE 4 PROFILES 24 12 CELSIUS FAHRENHEIT OPTION 25 13 REPLACING THE BATTERY 26 14 DISPOSAL OF THE DEVICE ENVIRONMENT 27 15 GENERAL INFORMATION 28 16 DESCRIPTION OF THE WIRELESS FUNCTIONS AND TECHNOLOGY 32 17 CARE AND CLEANING 34 17 1 CALIBRATION 34 18 TROUBLESHOOTING 35 19 NORMALIZED SYMBOLS 37 20 IMPORTANT INFORMATI...

Page 7: ...reatly from that of the measuring area please wait until the thermometer temperature has equalized to the room temperature about 30 minutes prior to use Keep the device out of the reach of children and pets to avoid inhalation or swallowing of small parts Do not allow children to take their temperatures unattended Children may not be able to use the device in accordance with the instructions in th...

Page 8: ... knowledge and technology being incomplete other potential allergic reactions may not yet be known Should you have an allergic reaction to the materials please stop treatment immediately and consult your physician Store the thermometer in a dry clean place Do not expose the product to chemical solvents lint dust direct sunshine or high temperature During use the operator shall prevent simultaneous...

Page 9: ...hing Outside temperature Time of day Body temperature is lower in the morning and increases throughout the day towards evening Activities Physical and to a lesser extent mental activities increase body temperature This is why we recommend that you practice using the thermometer on yourself and family members when you are healthy By doing so you will know how the thermometer works and will feel mor...

Page 10: ...ure the forehead is clean If you clean the forehead please keep waiting a further 5 to 10 minutes before measuring 3 If the temperature of the storage area differs greatly from that of the measuring area please wait until the thermometer temperature has equalized to the room temperature about 30 minutes prior to use 4 Please open the battery cover and install 2 AAA batteries which can be found ins...

Page 11: ...H System Requirement 11 4 SYSTEM REQUIREMENT Smartphones Tablets Android and iOS only System Requirements iOS 8 0 Android 4 2 or above For more information please visit https hubbleconnected com requirements ...

Page 12: ...p Store to search for Hubble Connect for Smart Nursery Download the Hubble Connect for Smart Nursery app and install it on your iPhone iPad Run the Hubble Connect for Smart Nursery app on your Android device iPhone iPad Run the Hubble Connect for Smart Nursery App tap SIGNUP and follow the in app instructions to create your Smart Nursery account By signing up you agree to our Terms Conditions Note...

Page 13: ...that Bluetooth on your mobile device is activated when pairing is in progress Run the Hubble Connect for Smart Nursery app tap SIGNUP and follow the in app instructions to create your Smart Nursery Account By signing up you agree to our Terms Conditions Pictures A1 A2 A1 A2 Note If you already have a Smart Nursery app account please tap LOGIN enter your account information and proceed to the next ...

Page 14: ... Pairing The Thermometer To Your Mobile Device Tap on the Smart Touchless Forehead Thermometer to enter thermometer set up mode Picture A3 A3 Tap Skip to set up or scroll to review features Picture A4 A4 ...

Page 15: ...The Thermometer To Your Mobile Device 15 Follow Step 1 Make sure that your thermometer is switched on then press Next Picture A5 A5 Follow Step 2 Pair the thermometer with your mobile device via Bluetooth Picture A6 A6 ...

Page 16: ...16 Pairing The Thermometer To Your Mobile Device Searching for your device Picture A7 A7 Found your device Please press on MBP70 XXX Picture A8 A8 ...

Page 17: ...Pairing The Thermometer To Your Mobile Device 17 Pairing the thermometer with your smart device Picture A9 A9 You have now successfully paired the thermometer with your smart device Tap Continue Picture A10 A10 ...

Page 18: ... Device User guide screen Picture A11 A11 You can now start using the thermometer Picture A12 A12 Note Your personal health data can only be transmitted when the app is on The thermometer switches off automatically after 60 seconds of non use ...

Page 19: ...onnected to the smartphone Offline Indicates that the thermometer is not connected to the smartphone Number of readings Indicates the numbers of temperature readings taken Schedule Manager Calendar to manage doctor appointments reminders and prescriptions Reading Log Can view saved readings As Numbers As Graphics Celsius C and Fahrenheit F Celsius C and Fahrenheit F switchable ...

Page 20: ...ure Led Indication 7 TEMPERATURE LED INDICATION Two colors are used to provide LED indications Green LED 34 0 C 93 2 F to 37 9 C 100 3 F Normal Temperature Red LED 38 0 C 100 4 F to 42 9 C 109 3 F High Temperature ...

Page 21: ...tes before taking a temperature 2 In object measurement mode the current surface temperature of the object is displayed This may be different from its internal temperature especially if its surface is exposed to direct sunlight or a draft 3 Temperatures measured using different thermometers should never be compared to each other Tell your doctor what type of thermometer you used to take your tempe...

Page 22: ...t is complete 3 Read the temperature on the display Caution After pressing the measurement button the distance sensor will detect the distance between the forehead and thermometer If the distance is between 0 to 5 cm 0 to 2 inches the device will directly test the forehead temperature If the distance exceeds 5 cm 2 inches the didi sound will be produced indicating that the thermometer should be br...

Page 23: ...suring mode Note Do not use this mode to measure body temperature 2 Hold the thermometer and ensure the probe is approximately 0 to 5 cm 0 to 2 inches from the liquid or surface whose temperature you want to measure Press the button to start 3 Remove the thermometer from the object The LCD screen displays the temperature You can press the buttons to return to standby mode The thermometer will auto...

Page 24: ...ied the earliest measurement is always deleted from the memory Press the button to check the memory data The LCD screen displays memory number and measured temperature Press the button repeatedly to go to the desired memory number Press and button at the same time to return to standby mode 11 1 SELECTING THE USER PROFILE 4 PROFILES Press and hold for 2 seconds to select the desired user profile Pl...

Page 25: ...renheit Option 25 12 CELSIUS FAHRENHEIT OPTION In standby mode you can switch between Celsius C and Fahrenheit F by pressing and holding and the button at the same time for 2 seconds until you hear one or two beep sounds ...

Page 26: ... sure to properly install the batteries in accordance with the positive and negative polarity symbols marked in the battery compartment Slide the battery cover back in until it snaps in place Caution To protect the environment dispose of exhausted batteries in accordance with current federal state and local regulations Keep batteries out of the reach of children Remove the batteries when the unit ...

Page 27: ... used By reusing some parts or raw materials from used products you make an important contribution to the protection of the environment Exhausted batteries do not belong with household waste Dispose of batteries in accordance with the current federal state and local regulations As a consumer you are legally obligated to return used batteries NOTES 1 In environments where there is a high frequency ...

Page 28: ...be free from defects in materials and workmanship under normal consumer usage for the period outlined below This Warranty is your exclusive warranty and is not transferable Who is covered This Warranty extends only to the first consumer purchaser and is not transferable What will BINATONE do BINATONE or its authorized distributor at its option and within a commercially reasonable time will at no c...

Page 29: ...ion on the length of an implied warranty so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may also have other rights that vary from one jurisdiction to another Products Covered Length of Coverage Consumer Products One 1 year from the date of the products original purchase by the first consumer purchaser of the product Consumer Access...

Page 30: ...E or its authorized service centers are excluded from coverage Altered Products Products or Accessories with a serial numbers or date tags that have been removed altered or obliterated b broken seals or that show evidence of tampering c mismatched board serial numbers or d non conforming or non Motorola branded housings or parts are excluded from coverage Communication Services Defects damages or ...

Page 31: ...ng the Products or Accessories purchased by you and supersede any prior agreement or representations including representations made in any literature publications or promotional materials issued by BINATONE or representations made by any agent employee or staff of BINATONE that may have been made in connection with the said purchase ...

Page 32: ...ate in the unlicensed 2 4 GHz ISM Industrial Scientific Medical band BLE4 1 wireless technology has 40 channels 3 broadcasting channels 37 data channels each channel spacing 2MHz over the entire operating frequency range 2 402 2 480GHZ A frequency hopping transceiver is used to combat interference and fading The modulation method is GFSK the output power is 0 dBm and the maximum transmission range...

Page 33: ...arding radio frequency baseband protocol and link management protocol The AES 128 CCM algorithm ensures the security of the data 4 This device emits very low levels in the radio frequency RF interval and is therefore not likely to cause any interference with nearby electronic equipment radios computers telephones etc 5 The MBP70SN device is designed to withstand foreseeable disturbances originatin...

Page 34: ...hermometer using an abrasive cleanser thinner or benzene nor immerse the thermometer in water or other liquids After cleaning place the thermometer in its protective case Store it in a clean dry place at room temperature Never expose the thermometer to extreme temperatures humidity direct sunlight or shock 17 1 CALIBRATION The thermometer is initially calibrated during manufacturing before ex fact...

Page 35: ...move battery and reinsert correctly The measured temperature is lower than 34 0 C 93 2 F or higher than 42 9 C 109 3 F Please check the operation method Follow user manual for proper measurement Hardware problem Contact Motorola customer service or your local store Operating temperature is out of the range Use the thermometer in the prescribed range of operating conditions The sensor temperature h...

Page 36: ...e in the room for at least 30 minutes Please keep the thermometer and patient in the measuring room at least 30 minutes prior to use Are you using the thermometer indoors Please ensure that you take temperature indoors Please check if you have held the thermometer in your hand for too long thus affecting its accuracy Put the thermometer on a table in the room where the measurement is being taken a...

Page 37: ...ution Refer to the Instruction Manual IP22 The first number 2 Protection against solid foreign objects of 12 5 mm Ф and greater The second number Protection against vertically falling water drops when enclosure is tilted up to 15 Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15 on either side of the vertical SN Indicate the manufacturing dat...

Page 38: ...ines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices Medical devices manufactured by Shenzhen Dongdixin Technology Co Ltd conform to this IEC 60601 1 2 2014 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories and cables other than those specified by ma...

Page 39: ...uidance RF emissions CISPR 11 Group 1 The thermometer only uses RF energy for its internal operation Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The thermometer is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power ...

Page 40: ...kV air 6 kV contact 8 kV air Floors should be made of wood concrete or ceramic tile If floors are covered with synthetic materials the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 Not applicable Not applicable Not applicable Surge IEC 61000 4 5 Not applicable Not applicable Not applicable Voltage dips short interruptions and voltage variations of power supp...

Page 41: ... 3 Not applicable 3 V m 80 MHz to 2 5 GHz 3 V m When used near any part of the thermometer including cables portable and mobile RF communications equipment should not be used any closer than the recommended separation distance calculated based on the equation appropriate to the frequency of the transmitter Recommended separation distance d 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5 GHz...

Page 42: ... as base stations for radio cellular cordless telephones and land mobile radio AM and FM radio broadcast and TV broadcast cannot be accurately predicted theoretically To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the thermometer is to be used exceeds the above applic...

Page 43: ... Transmitter in Watts Separation Distance Based on the Frequency of the Transmitter in Meters 150 kHz to 80 MHZ d 1 2 P 80 MHz to 800 MHZ d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equ...

Page 44: ...unications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the...

Page 45: ...complies with the Industry Canada license exempt RSS standard s Operation is subject to the following Two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device ...

Page 46: ...nd Dimensions 130 1 L x 45 0 W x 50 3 D mm Weight About 92 0g without battery Operating conditions Forehead 15 0 C to 40 0 C 59 0 F to 104 0 F Object 10 0 C to 40 0 C 50 0 F to 104 0 F with a relative humidity of 15 to 85 Storage and transportation conditions 20 C to 55 C 4 F to 131 F with a relative humidity of 15 to 90 Atmospheric pressure 700 hPa to 1060 hPa Maximum separation distance 10 m in ...

Page 47: ......

Page 48: ... of Motorola Trademark Holdings LLC and are used under license Apple logo is a trademark of Apple Inc registered in the U S and other countries App Store is a service mark of Apple Inc Google Play and Android are trademarks of Google Inc All other trademarks are the property of their respective owners 2017 Motorola Mobility LLC All rights reserved US_EN Version 1 0 Printed in China ...

Reviews: