background image

●Before starting installation, read the following safety precautions.
●The following precautions must be observed as it describes the serious matters for safety.
●The safety precautions are described as follows with the degree of danger  that occurs when the terminal block is handled wrong.

Describes precautions that must be observed to prevent danger of injury or death to the user.

Describes precautions that must be observed to prevent damage to the unit.

●After installation, make test operation and confirm that it works properly

Tell your customers to keep this installation manual together with the operation manual with them, and when they give or 
sell this machine to other person put this installation manual and operation manual with it.

CAUTION

Ask installation to the dealer or an authorised technician.

If the terminal block is installed improperly by the customer, water leakage , electric shock, or fire may result.

Follow the installation manual to install the terminal block securely.

If the terminal block is installed improperly, water leakage , electric shock, or fire  or other incidents may result.

Electrical wiring must be performed with electrical cables that do not exceed capacity.

Short circuit, heat generation, or fire may result.

WARNING

WARNING

Safety Precautions

CAUTION

WARNING

1. Outline

The terminal block is used as a relay to wire an indoor unit and two remote controllers or to wire a remote controller and multi-

ple indoor units in order to perform grouping control.

2. Applicable model

   Wall-mounting type (PKA-RP·KAL, PKA-RP·HAL)

3. Included parts

     Terminal block (TB5) ·······1     

 

Screw ·······1        Wire cable ·······1 (240 mm)   

4.  Installation procedure 

PKA-RP·KAL

1).  Open the front grille and remove the 2 screws.

2). Remove the 3 screw covers and the 3 front panel screws.

3).  Pull out the bottom of the front panel to the front. 

Note: Beware that the panel does not contact with the vane while in the procedure.

4).   Remove the terminal block cover and  the control board cover by removing their respective screws.  

Note:  Be sure to keep the washers at hand.

Package Air Conditioner Optional Parts

Remote Controller Terminal Block Kit Installation Manual 

Model No: PAC-SH29TC-E

Screws (2)

Pull out the bottom of the front 

panel  to the front.

Open the grill and 

remove the 2 screws

Screw covers & screws (3)

Control board cover

Screw & washer

Electrical box cover

Screw & washer

Continued overleaf.

RG79L644H03