Enclosure surface operation panel 

FR-PA07

INSTRUCTION MANUAL

INVERTER

Thank you for purchasing the enclosure surface operation panel (FR-PA07). This instruction manual
gives handling information and precautions for use of this product. Incorrect handling might cause
an unexpected fault. Before using this product, please read this manual carefully to use this product
to its optimum performance.
Please forward this instruction manual to the end user.
This product is an option dedicated for the FR-E800 */E700/D700/F700PJ/E700EX/D700-G series.
Refer to the inverter unit's Instruction manual for details on the operation panel functions, operation
methods and handling methods.

* Only the FR-E800 standard model is supported.

1. Connection

• Use the FR-CB20

 connection cable. Insert one end of the cable into the PU connector on the

inverter, and the other end into the connection connector on the FR-PA07 along the guides until
the clips click into place. (For the details of the FR-CB20

, refer to the Instruction Manual of the

FR-CB20

.)

• To disconnect the cable, hold down the clip at the cable end and gently pull the connector.

 Safety precautions

Do not touch the setting dial or keys with wed hands. Doing so may cause an electric shock.

Do not install and operate the enclosure surface operation panel (FR-PA07) if it is damaged 
or has parts missing.

Provide a safety backup device, such as an emergency brake, to protect machines and 
product from hazardous conditions if the enclosure surface operation panel (FR-PA07) 
becomes faulty.

Static electricity in your body must be discharged before you touch the product. Otherwise 
the product may be damaged.

If halogens (including fluorine, chlorine, bromine, and iodine) contained in fumigants for wood 
packages enter this product, the product may be damaged. Prevent the entry of fumigant 
residuals or use an alternative method such as heat disinfection. Note that sterilization or 
disinfection of wood packages should be performed before packing the product.

NOTE

Do not start operation with the inverter front cover removed.  

Clip

FR-PA07 (back)

PU connector

Clip

Example: FR-E700

Summary of Contents for FR-PA07

Page 1: ... the details of the FR CB20 refer to the Instruction Manual of the FR CB20 To disconnect the cable hold down the clip at the cable end and gently pull the connector Safety precautions Do not touch the setting dial or keys with wed hands Doing so may cause an electric shock Do not install and operate the enclosure surface operation panel FR PA07 if it is damaged or has parts missing Provide a safet...

Page 2: ...nitoring mode Operation mode indication PU Lit to indicate PU operation mode EXT Lit to indicate external operation mode PU EXT Flicker to indicate network operation mode Setting dial Setting dial Mitsubishi Electric inverter dial Used to change the frequency setting and parameter values Mode switchover Used to change each setting mode Stop operation Uses to stop the operation command When a fault...

Page 3: ... MODE S MODE S MODE S T PU EXT DE SET P E Operation mode switchover At power ON external operation mode PU operation mode output frequency monitor Monitor frequency setting Value change Output current monitor Parameter setting Parameter setting mode Fault history PU Jog operation mode Example Example and frequency alternating Frequency setting written and complete Output voltage monitor Display th...

Page 4: ...t parameter change and unexpected start or frequency setting POINT Set 10 or 11 key lock mode valid in Pr 161 Frequency setting key lock operation selection Operation Display 1 Screen at powering on The monitor display appears 2 Press to choose the PU operation mode PU indication is lit 3 Press to choose the parameter setting mode The parameter number read previously appears 4 Turn until Pr 161 ap...

Page 5: ...ge 4 for change of the setting Press twice to return the monitor to frequency monitor 4 Press to start the inverter 5 Turn until 60 00 Hz appears The blinking frequency is the set frequency You need not press The frequency blinks for about 5s REMARKS If blinking 60 00 turns to 0 00 the Pr 161 Frequency setting key lock operation selection setting may not be 1 Independently of whether the inverter ...

Page 6: ...ng Ambient humidity 90 RH or less non condensing Storage temperature 20 C to 60 C Ambience Indoors free from corrosive gas flammable gas oil mist dust and dirt Altitude vibration Maximum 1000m above sea level for standard operation 5 9m s2 or less at 10 to 55 Hz directions of X Y Z axes Power supply Power is supplied from the inverter Connection method Connection using the parameter unit connectio...

Page 7: ...ion Manual of the inverter for the position of the rating plate The parameter copy menu is not displayed on this product connected to FR E700 series inverters manufactured after the above period The parameter copy is not displayed on this product when connected to FR E800 series inverters Rating plate example The SERIAL consists of one symbol two characters indicating production year and month and...

Page 8: ...rdous Substances in Electrical and Electronic Products of the People s Republic of China 电器电子产品有害物质限制使用标识要求 本产品中所含有的有害物质的名称 含量 含有部件如下表所示 产品中所含有害物质的名称及含量 上表依据SJ T11364的规定编制 表示该有害物质在该部件所有均质材料中的含量均在GB T26572规定的限量要求以下 表示该有害物质在该部件的至少一种均质材料中的含量超出GB T26572规定的限量要求 1 即使表中记载为 根据产品型号 也可能会有有害物质的含量为限制值以下的情况 2 根据产品型号 一部分部件可能不包含在产品中 环境保护使用期限标识 部件名称 2 有害物质 1 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 电路板组件 包括印刷...

Reviews: