background image

TECHNICAL BULLETIN

[   1 / 9 ]

FA-A-0326-C

 

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN

Applicable Network Cameras for Camera Recorder Module

Date of Issue

February 2021 (Ver. C: July 2021)

Relevant Models

RD81RC96-CA

Thank you for your continued support of Mitsubishi Electric programmable controllers, MELSEC iQ-R series.
This bulletin introduces network cameras applicable to a camera recorder module.
For the product availability, please contact the manufacturer.

1

PRECAUTIONS

Specifications of the applicable products are subject to change without notice.
Before using the product, please read "SAFETY PRECAUTIONS" of User's Manual.
For precautions on wiring of each product, refer to the manual for the product.

1.1

Precautions for Network Cameras

Network cameras manufactured by Axis Communications

 • The capture mode and power line frequency must be set according to a frame rate to be set in a camera recorder module. 

(

Page 5 Setting an IP address etc.)

For the specifications of the capture mode, refer to the manual for a network camera.

Network cameras manufactured by CANON INC.

 • If a resolution to be set in a camera recorder module or GOT does not appear in the communication test screen in the 

module extended parameter, change the setting of the video size set for a network camera. (

Page 7 Setting a video 

size set)

 • If neither PTZ operation nor preset movement is available, release the camera control authority.
For details on the setting method, refer to the manual for a network camera used.

Network cameras manufactured by Panasonic i-PRO Sensing Solutions Co., Ltd.

 • If a resolution to be set in a camera recorder module or GOT does not appear in the communication test screen in the 

module extended parameter, change the setting of the image capture mode for a network camera. (

Page 9 Setting an 

image capture mode)

For details on the setting method, refer to the manual for a network camera used.

Summary of Contents for FA-A-0326-C

Page 1: ...apture mode and power line frequency must be set according to a frame rate to be set in a camera recorder module Page 5 Setting an IP address etc For the specifications of the capture mode refer to the manual for a network camera Network cameras manufactured by CANON INC If a resolution to be set in a camera recorder module or GOT does not appear in the communication test screen in the module exte...

Page 2: ...n Network Video Interface Forum interface Manufacturer Product Series Model name Axis Communications AB Fixed box camera AXIS M10 M1065 LW M1065 L M1045 LW AXIS Q16 Q1645 AXIS P13 P1375 E P1377 AXIS M11 M1135 Fixed dome camera AXIS Q35 Q3515 LVE AXIS P32 P3245 LVE Pan tilt zoom PTZ camera AXIS M55 M5525 E AXIS M50 M5065 M5054 Modular camera AXIS F F41 F44 AXIS P12 P1275 P1265 P1245 CANON INC Compa...

Page 3: ...tream Network cameras manufactured by CANON INC The following shows the confirmed version and the availability of each function when connecting each model to a camera recorder module Each function can be used only when selecting the simple setting mode in a camera recorder module Available Not available Model name Firmware version Function Active LTS Recording function Camera adjustment function P...

Page 4: ...ettings as necessary Outline of network connection settings The following shows the procedure outline for setting an IP address etc 1 Connect a network camera and personal computer to a network 2 Check the IP address initial value of the network camera 3 Set the IP address for the personal computer to be in the same segment as the IP address of the network camera 4 Access the network camera from t...

Page 5: ...essing the web server 2 Set a password and language to use and click the Create login button The password must be 32 characters or less in length to access the network camera from a camera recorder module 3 Enter the set user name and password to log in to the network camera 4 Set the necessary information according to instructions shown in the screen The maximum frame rate of a network camera var...

Page 6: ...work camera by checking the image Setting an ONVIF user The following shows the procedure for setting an ONVIF user Set it with a personal computer and network camera connected after setting an IP address Operating procedure 1 Enter the IP address of a network camera on a web browser 2 Enter the set user name and password to log in to the network camera 3 Select Settings System ONVIF 4 Click below...

Page 7: ...o log in to the network camera The settings menu appears 4 Select Basic Network and set IPv4 Address Settings Method to Manual under IPv4 5 Set an IP address and click the Apply and reboot button Once the IP address is changed the connection is disconnected Close the web browser Setting a video size set The following shows the procedure for setting a video size set Set it with a personal computer ...

Page 8: ...when accessing the web server 2 Set a user name and password and click the Set button 3 Enter the set user name and password to log in to the network camera The live page appears 4 Click the Setup button 5 Set Network Settings to Static under IPv4 network in Network 6 Set an IP address and click the Set button Once the IP address is changed the connection is disconnected Close the web browser Sett...

Page 9: ... select a mode including a resolution to be set in a camera recorder module for Image capture mode 5 Click the Set button The change is applied REVISIONS TRADEMARKS AXIS and AXIS COMMUNICATIONS are either trademarks or registered trademarks of AXIS AB in various jurisdictions ONVIF is a trademark of Onvif Inc The company names system names and product names mentioned in this bulletin are either re...

Reviews: