background image

Operating and installation instructions

External motors
AWG 102
MG 100
DDG 102
ABLG 200

Roof vent kit
DDF 125/150

To avoid the risk of accidents or
damage to the appliance it is

essential

to read these operating instructions

before it is installed or used for the first time.

G

M.-Nr. 06 017 040

Summary of Contents for AWG 102

Page 1: ...nal motors AWG 102 MG 100 DDG 102 ABLG 200 Roof vent kit DDF 125 150 To avoid the risk of accidents or damage to the appliance it is essential to read these operating instructions before it is installed or used for the first time G M Nr 06 017 040 ...

Page 2: ...e environment 3 Warning and Safety instructions 4 Electrical connection 7 Technical data 8 Installation 9 AWG 102 9 MG 100 12 DDG 102 14 ABLG 200 16 DDF 125 150 19 Extraction ducting 20 Condensate trap 20 Contents 2 ...

Page 3: ...Danger of suffocation Rather than just throwing these materials away please ensure that they are recycled Disposal of your old appliance Old appliances contain materials which can be reclaimed or recycled Please contact your dealer your local waste collection centre or scrap merchant about potential recycling schemes Ensure that the appliance presents no danger to children while being stored for d...

Page 4: ...otherwise the appliance could get damaged If in any doubt consult a qualified electrician The electrical safety of this appliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national safety regulations It is most important that this basic safety requirement is present and regularly tested and where there is...

Page 5: ...e Spare Parts department or from builders merchants The appliance must not be connected to a chimney or vent flue which is in use Neither should it be connected to ducting which ventilates rooms with fireplaces N B AWG 102 The external motor must be installed vertically on the outside wall The extraction outlet must face downwards N B ABLG 200 If exhaust air is to be extracted into a chimney or ve...

Page 6: ...sible Ventilation can be maintained by air inlets which cannot be blocked in windows doors and outside wall vents or by other technical measures such as ensuring that the extractor can only be switched on when the heating appliance is switched off or vice versa Note The overall ventilation condition of the dwelling must be taken into account If in any doubt the advice of a competent builder or for...

Page 7: ...ernal motor is supplied with a 3 m long extension cable If the control cable needs to be extended further or if it is to be connected to a fixed connection point the installation must be carried out in accordance with VDE 0100 0700 Part 1 and with local and national safety regulations Equipotential bonding must be carried out There is a screw connection point on the external motor marked with the ...

Page 8: ... in practice max 720 m3 h MG 100 Rated load 330 W Voltage AC 230 V Frequency 50 Hz Fuse rating UK 13 A Control cable length 0 75 m Extension cable length 3 m Extraction power unrestricted 240 850 m3 h in practice max 730 m3 h DDG 102 Rated load 165 W Voltage AC 230 V Frequency 50 Hz Fuse rating UK 13 A Control cable length 0 75 m Extension cable length 3 m Extraction power unrestricted 440 1 000 m...

Page 9: ...he control panel on the cooker hood Please refer to the operating and installation instructions for the cooker hood before installing the external motor and ducting Unscrew the 2 fixing screws on the underside of the appliance and take the motor unit off of its fixing bracket The ducting stub on the motor unit has a diameter of 125 mm when the appliance is supplied If a diameter of 150 mm is requi...

Page 10: ...ns for three drill holes Drill three 8 mm C holes and plug with S8 plugs Connect the 3 mountings through the fixing holes in the bracket as illustrated Position the bracket onto the outside wall again and feed the control cable with the six pole connectors through the telescopic wall pipe into the house If equipotential bonding is required pull the earth cable through the gap provided Equipotentia...

Page 11: ... the flexible ducting from the inside of the wall and seal the gap between the ducting and the wall pipe with jointing compound Fit the motor unit over the bracket and secure it in position Connect the control cable plug connectors Use the extension cable supplied to lengthen the cabling if necessary If it is still not long enough please refer to the notes in Electrical connection Installation 11 ...

Page 12: ...motor and ducting aEquipotential bonding extends from 280 390 mm Make a hole 280 mm wide x 240 mm deep through the wall Extend the size of the hole on the outside wall side downwards to make it 365 mm high and into the wall to a depth of approx 150 mm Use a crosstip screwdriver to remove the screws from the appliance cover A and take off the cover Screw brackets B supplied by the angled section to...

Page 13: ...nd the housing Secure stainless steel cover A to the housing using a crosstip screwdriver The ducting stub on the motor unit has a diameter of 150 mm when the appliance is supplied Please fit the adapter supplied if a diameter of 125 mm is required Push the flexible ducting onto the stub on the motor unit and secure it with a hose clip Connect the control cable plug connectors Use the extension ca...

Page 14: ... of roofing This motor is not suitable for installation on flat roofs Installation must only be carried out by a qualified roof tiler The external motor is connected to the cooker hood by means of a control cable and is operated by the control panel on the cooker hood Please refer to the notes in Connection for air extraction before installing the external motor and ducting Installation 14 ...

Page 15: ...ld be fitted under the roofing at the top of the motor and above the roofing at the sides and the bottom of the motor Push the flexible vent ducting onto the ducting stub on the motor unit and secure it with a hose clip Connect the control cable plug connectors Use the extension cable supplied to extend the length of the connection cable if necessary Equipotential bonding is required if the contro...

Page 16: ...l panel on the cooker hood Please refer to the operating and installation instructions for the cooker hood before installing the external motor and ducting When positioning the external motor you must pay particular attention to the direction of the ducting Mark the positions for the four motor base plate holes on the installation surface Place the motor to one side Drill four C 8 mm holes in the ...

Page 17: ...ease refer to the notes in Electrical connection The ducting stub on the motor unit has a diameter of 125 mm when the appliance is supplied If a diameter of 150 mm is required the front ring of the stub must be cut off at the join with a sharp knife see illustration Push the flexible ducting onto the stub on the motor unit and secure it with a hose clip Installation 17 ...

Page 18: ...e smaller than 125 mm C Otherwise extraction will be less efficient If the exhaust air is to be ducted into the open air a telescopic wall vent kit can be used This is available to order as an optional accessory from your dealer or the Miele Spare Parts Dept Installation 18 ...

Page 19: ...the air outlet directed down the roof Secure the vent kit to the roof substructure with the fixing plate Replace the roofing Press down on the flashing to ensure that it creates a proper seal The flashing should be fitted under the roofing at the top and above the roofing at the sides and the bottom The vent kit stub has a diameter of 125 mm when the appliance is supplied If a diameter of 150 mm i...

Page 20: ...f the cooker hood Only use smooth pipes or flexible hoses made from non flammable materials for extraction connection Where ducting is horizontal it must be laid to slope away at at least 1 cm per metre This is to ensure that condensate cannot drain back into the cooker hood Important If the exhaust ducting is to run through rooms ceiling space etc where there may be great variations in temperatur...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ...Alteration rights reserved 2403 This paper consists of cellulose which as been bleached without the use of chlorine M Nr 06 017 040 00 ...