background image

Operating and Installation
Instructions

Ventilation System
DAR 1120, 1130, 1150
DAR 1220, 1230, 1250

To prevent accidents
and appliance damage,
read these instructions

before

installation or use.

M.-Nr. 09 824 260

en - US, CA

Summary of Contents for 09 824 260

Page 1: ...ing and Installation Instructions Ventilation System DAR 1120 1130 1150 DAR 1220 1230 1250 To prevent accidents and appliance damage read these instructions before installation or use M Nr 09 824 260 en US CA ...

Page 2: ...ower level 11 Intensive level 11 Cleaning and Care 12 Cleaning the casing 12 Baffle filtration 13 OdorFree charcoal filters 15 After Sales Service 16 Installation instructions 17 Caring for the environment 18 Appliance dimensions 19 Plywood backing 26 Installation 27 Installation instructions 27 Protective film 27 Air extraction 28 Electrical connection 30 Technical data 31 Contents 2 ...

Page 3: ...sed in a non stationary location e g on a ship WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this appliance only in the manner intended by the manufacturer If you have questions contact Miele b Before servicing or cleaning the appliance switch power off at the service panel and lock the service disconnecting means to prevent power from being swi...

Page 4: ...ectrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults g Before discarding an old appliance disconnect it from the power supply and remove the power cord to prevent hazards Use WARNING TO REDUCE THE RISK OF A COOKTOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers may i...

Page 5: ...ended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance CAUTION Accessible parts may become hot when used with coo...

Page 6: ... connect the appliance to electricity Extension cords do not guarantee the required safety of the appliance e g danger of overheating g Do not install this hood over cooktops that burn solid fuel h Provided a larger distance is not given by the manufacturer of the cooktop follow the minimum safety distances between a cooktop and the bottom of the hood given in the Appliance dimensions section of t...

Page 7: ...ned on the air pressure of the exhaust blower opens the flap and blows the cooking vapors outside Air extraction with external blower The external blower must be installed outside the room at a location of your choosing The external blower is connected to the ventilation system by a control cable and is operated via the control panel of the ventilation system Air recirculation mode The air that is...

Page 8: ...Guide to the Ventilation System 8 ...

Page 9: ...tion mode cVentilation hood d OdorFree charcoal filter behind baffle filtration Optional accessory for air recirculation eBaffle filtration fOverhead LED light On Off switch gControl panel hGrease collecting tray iOverhead LED light switch jBlower control On Off switch plus 4 fan speeds Guide to the Ventilation System 9 ...

Page 10: ... Blower DRIB XL 700 cfm or DRIB XXL 1100 cfm Blower DREB XL 700 cfm or DREB XXL 1100 cfm Blower DRIB XL recirculation kit DRUU 30 DRDC 3006 6 DRDC 3012 12 DRDC 3018 18 DRDC 3024 24 Range Wall Hood DAR 1230 36 Blower DRIB XL 700 cfm or DRIB XXL 1100 cfm Blower DREB XL 700 cfm or DREB XXL 1100 cfm DRIB XL recirculation kit DRUU 36 DRDC 3606 6 DRDC 3612 12 DRDC 3618 18 DRDC 3624 24 Range Wall Hood DA...

Page 11: ...em on when cooking When using a gas range regardless of the cooktop setting use the following power levels Ventilation system with blower DRIB XL or DREB XL 700 cfm 22 kW or more min Level 2 31 kW or more min Level 3 Ventilation system with blower DRIB XXL or DREB XXL 1100 cfm 31 kW or more min Level 2 40 kW min Level 3 The ventilation system is equipped with a temperature sensor If an insufficien...

Page 12: ...he electronics and cause damage Wipe dry using a soft cloth Avoid cleaning agents containing soda acids or chlorides abrasive cleaning agents e g powder or cream cleansers abrasive sponges e g pot scourers or sponges which have been previously used with abrasive cleaning agents These will damage the surface The following instructions for cleaning Stainless steel surfaces and Stainless steel colore...

Page 13: ...tchen air grease dust etc and prevent soiling of the ventilation system The baffle filters should be cleaned every 3 4 weeks A dirty filter is a fire hazard Push the baffle filter slightly upwards a pull the lower side out b and remove the filter Support the baffle filter so that it does not fall and damage the cooktop The OdorFree charcoal filters mounted in back of the baffle filters should be r...

Page 14: ...dish soap Do not use the pure detergent aggressive all purpose cleaners oven sprays abrasive cleaning agents or limescale removers They could damage the filter After cleaning place the filters on a towel to air dry While the filters are removed clean any dirt or grease from the filter casing The bottom lip that the baffle filter sits on serves as a grease collecting tray that can be removed for cl...

Page 15: ...he filters according to the instructions included with the kit Replacement OdorFree charcoal filters can be ordered from Miele Replacing the OdorFree charcoal filters To install or replace the OdorFree charcoal filters the baffle filters must first be removed as described in the previous section Remove the filters from the packaging Open the filter housing Insert the OdorFree charcoal filter Repea...

Page 16: ...irs by a Miele Authorized Service Provider using genuine Miele parts Only genuine Miele parts installed by factory trained professionals can guarantee the safety reliability and longevity of your Miele appliance Please note that unless expressly approved in writing by Miele s Service department Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele...

Page 17: ...g this ventilation system The installation steps are described in the enclosed Installation Diagram Leave these instructions with the appliance for the consumer user Information is subject to change Please refer to our website to obtain the most current product specification technical warranty information ...

Page 18: ...sed of safely and kept out of the reach of babies and young children Danger of suffocation Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling center about the possibility of recycling these materials Before discarding an old appliance disconnect it from the electrical supply and cut off the power cord to prevent it from becomi...

Page 19: ...Appliance dimensions 19 ...

Page 20: ...Appliance dimensions 20 ...

Page 21: ...a The hood with exhaust collar is only used in air extraction mode with an internal or external blower Appliance dimensions 21 ...

Page 22: ...a The hood with exhaust collar is only used in air extraction mode with an internal or external blower Appliance dimensions 22 S ...

Page 23: ...Appliance dimensions 23 ...

Page 24: ... flammable materials e g upper cabinets If local building codes require a greater safety distance follow their requirement If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance See Important Safety Instructions for further information To ensure free access to work under the ventilation hood a distance of a minimum o...

Page 25: ...7 KW and no burner 18 800 BTU hr 5 5 KW 30 760 mm Miele Multiburner Gas cooktops 92 200 BTU hr 27 KW 109 200 BTU hr 32 KW and no burner 18 800 BTU hr 5 5 KW not possible 36 910 mm 30 760 mm Miele Multiburner Gas cooktops 109 200 BTU hr 32 KW 136 500 BTU hr 40 KW and no burner 18 800 BTU hr 5 5 KW not possible 36 910 mm Miele Multiburner Gas cooktops 136 500 BTU hr 40 KW not possible Miele Multibur...

Page 26: ...agram To install a plywood backing Determine and mark the location for the canopy as outlined in Appliance dimensions Make a cutting line 3 76 mm above and 3 76 mm below the outline of the retaining plate Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line along the center of each stud CAUTION When cutting or drillin...

Page 27: ...and a furnace drawing interior air run at the same time Installation instructions The individual installation steps are described in the included Installation diagram Protective film stainless steel units The casing is covered with a protective film to prevent scratching during transport Please peel off the film before installing the casing parts It can be removed without tools Installation 27 ...

Page 28: ... and connections Use smooth or flexible pipework made from approved non flammable materials for exhaust ducting To achieve the most efficient air extraction and quietest noise levels consider the following The diameter of the ductwork should not be less than 8 203 mm with DRIB DREB XL and 10 254 mm with DRIB DREB XXL If flat ducting is used the cross section must not be smaller than the cross sect...

Page 29: ...ood to an active chimney dryer vent flue or room venting ductwork Seek professional advice before connecting an exhaust hood vent to an existing inactive chimney or vent flue Important If the ductwork runs through rooms ceilings garages etc where temperature variations exist it may need to be insulated to reduce condensation Air extraction 29 ...

Page 30: ...ctrical connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing a path of least resistance This appliance is equipped with a c...

Page 31: ... W DAR 1130 DAR 1230 3 x 2 W DAR 1150 DAR 1250 4 x 2 W Power supply voltage 120 V Frequency 60 Hz Circuit rating 15 A Weight DAR 1120 with DRIB XL 59 6 lbs 27 1 kg DAR 1220 with DRIB XL 83 8 lbs 38 1 kg DAR 1130 with DRIB XL 66 2 lbs 30 1 kg DAR 1130 with DRIB XXL 66 7 lbs 30 3 kg DAR 1230 with DRIB XL 97 lbs 44 1 kg DAR 1230 with DRIB XXL 97 5 lbs 44 3 kg DAR 1150 with DRIB XXL 79 9 lbs 36 3 kg D...

Page 32: ...Alteration rights reserved 5113 INFORMATION IS SUBJECT TO CHANGE PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS TECHNICAL WARRANTY INFORMATION M Nr 09 824 260 00 ...

Reviews: