background image

Model No.

 Description

PRODUCT

RP2300FC, RP2301FC
Router

Models RP2300FC and RP2301FC are upgraded sister tools of our current
plunge-type electronic router Model 3612C.   Their main benefits are:
   Linear ball bearing for super-smooth plunge action
   Ergonomically contoured knob style handles
   Powerful cutting with the continuous rating input higher than Model 3612C;
   RP2300FC: 2,300W, RP2301FC: 2,100W
   
RP2301FC additionally feature electric brake.

These products are available in the following variations.

T

ECHNICAL INFORMATION

C

ONCEPT AND MAIN APPLICATIONS

S

pecification

P  1/ 

27

12.0 or 12.7 (1/2)

No load speed: min

-1

=rpm

Collet capacity: mm (")

Double insulation
Power supply cord: m (ft)
Net weight*

2

: kg (lbs)

0 - 70 (0 - 2-3/4)

Plunge capacity: mm (")

9,000 - 22,000

Model No.

RP2301FC

RP2300FC

Yes*

1

Electric brake

LED job light

No

Yes

Yes

Europe: 4.0 (13.1), Brazil: 2.0 (6.6), Other countries: 2.5 (8.2)

6.1 (13.4)

Dimensions: mm  (")

Width (W1)
Height (H)

Length (L)

155 (6-1/8)

312 (12-1/4)

294 (11-5/8)

Width of base (W2)

170 (6-11/16)

H

W1

L

W2

*1: Twin LED job lights with afterglow function
*2 Weight according to EPTA-Procedure 01/2003, including Dust nozzle

RP2300FC

Model No.

Yes

Twin LED

 job lights

Standard type

(Straight guide + Guide holder assembly)

RP2300FCX

RP2301FC

RP2301FCX

No

Electric

brake

Yes

No

Yes

High-precision type with fine adjustment function

(Fine adjusting straight guide)

Straight guide

120

110

220
230
240

15

1,650

---

650

2,600

50/60

11

2,300

1,200

3,400

50/60

11

2,300

1,200

3,400

50/60

11

2,300

1,200

3,400

50/60

15

650

2,600

50/60

Continuous Rating (W)

Voltage (V)

Cycle (Hz)

Input

Output

Max. Output (W)

Current (A)

120

110

220
230
240

15

1,650

---

650

2,600

50/60

10

2,100

1,000

3,400

50/60

10

2,100

1,000

3,400

50/60

10

2,100

1,000

3,400

50/60

15

650

2,600

50/60

Continuous Rating (W)

Voltage (V)

Cycle (Hz)

Input

Output

Max. Output (W)

Current (A)

RP2301FC

RP2300FC

(See next page for Standard equipment and Optional accessories.)

Yes
Yes

Constant speed control

Variable speed control by dial

Soft start

Electronic

control

Yes

Summary of Contents for RP2300FC

Page 1: ...ns mm Width W1 Height H Length L 155 6 1 8 312 12 1 4 294 11 5 8 Width of base W2 170 6 11 16 H W1 L W2 1 Twin LED job lights with afterglow function 2 Weight according to EPTA Procedure 01 2003 including Dust nozzle RP2300FC Model No Yes Twin LED job lights Standard type Straight guide Guide holder assembly RP2300FCX RP2301FC RP2301FCX No Electric brake Yes No Yes High precision type with fine ad...

Page 2: ... 24 1 pc Optional accessories Fine adjusting straight guide Guide rail adapter set Trimmer guide assembly Templet guides Templet guide 25 Templet guide adapter 30 Nut M30 Dust nozzle assembly Collet sleeves Router bits Dust nozzle assembly 1 pc Knob 55 complete 1 pc Trimmer guide assembly 1 pc Templet guide 16 1 pc Collet sleeve 6mm 1 pc Collet sleeve 8mm 1 pc Collet sleeve 1 4 1 pc Collet sleeve ...

Page 3: ...DW Item No Apply lubricant VG100 to the following portions designated with the gray triangle to protect parts and product from unusual abrasion Description Armature Portion to lubricate DISASSEMBLING 1 Separate Base section from Motor section as illustrated in Figs 2 and 3 3 Remove M10 Thumb nut and M10 Nylon nut 24 Motor bracket complete Collet nut Motor housing 85 24 85 Base complete Threaded po...

Page 4: ... Base plate The other parts can be removed from Base complete as illustrated below Lock plate Compression spring 4 2pcs M5x10 Set bolt 2pcs Motor section M6 Hex nut M10 Screw Remove M6 Hex nut Flat washer 6 and M10 Screw Stopper Compression spring 5 Compression spring 7 Compression spring 7 Steel ball 7 1 M4x19 Thumb screw M5x14 Thumb screw M5x14 Thumb screw O ring 3 M6 Flat head screw O ring 8 Fl...

Page 5: ...let nut Remove Retainer cover by unscrewing M4x18 Pan head screw 2pcs Remove Cover by unscrewing 4x18 Tapping screw 2pcs Note It is impossible to disassemble Grip R without removing Cover M4x18 Pan head screw 2pcs 4x18 Tapping screw 2pcs 4x18 Tapping screw 2pcs Retainer cover Grip cover R Remove Grip cover R by unscrewing 4x18 Tapping screw 2pcs Repair Note Set Compression spring 4 2pcs in the gro...

Page 6: ...lever Lock off button Compression spring 5 Compression spring 4 from Grip R And remove Grip R from the machine by unscrewing M5x25 Pan head screw In case of Models RP1800 and RP1801 refer to Fig 11 M5x25 Pan Head screw Fig 9 Fig 10 Fig 11 Fig 12 Armature Motor bracket Remove Motor bracket together with Armature from Motor housing by removing 5x35 Tapping screw 4pcs 5x35 Tapping screw 4pcs 1R041 Re...

Page 7: ... 2 pcs of 1R258 remove Armature with Arbor press 1R258 Armature Bearing retainer 60 Ball bearing 6205DDW Remove Ball bearing 6205DDW by striking Motor bracket with Plastic hammer Bind CT4x12 Tapping screw 2pcs 4x12 Tapping screw 2pcs M4x14 Countersunk head screw 3pcs LED circuit Grip cover L Remove Grip cover L by unscrewing 4x12 Tapping screw 2pcs Grip L can be removed by unscrewing M6x25 Pan hea...

Page 8: ...d 18 Hooking the long tail of Torsion spring 15 on the wall of Motor bracket turn Lock lever without engaging the spline hole with the hex screw head of M10 Set bolt until it comes to the position illustrated right M10 Set bolt Lock lever Screw M10 Set bolt to Motor bracket with Lock Lever Put Torsion spring 15 into Lock lever so that the short tail of Torsion spring 15 faces Lock lever Putting th...

Page 9: ... Refer to left illustration in Fig 7 3 3 Shaft Lock 1 Separate Base section from Motor section as illustrated in Figs 2 3 2 Remove Retainer cover by unscrewing two M4x18 Pan head screws as the right illustration in Fig 7 3 Shaft lock mechanism can be disassembled as illustrated in Fig 19 Fig 19 1R268 Retainer cover Applying 1R268 to the pin hole of Push button strike Collared pin 6 through the pin...

Page 10: ...oil is used for some countries Black Makita logo side Name plate side Motor housing Grip R Controller Power supply cord LED Circuit Support Unit Chokecoil Switch Connector of Controller Connector of LED Yellow Red Fig D 1A This Lead wire may be blue for some countries Brown Lead wire is used for some countries Blue Lead wire is used for some countries P 10 27 ...

Page 11: ...ch to Terminal block Switch lever Connector of Controller The extra portion of Controller s thin Lead wires black red to be connected to LED has to be put in this position Connector of Controller s lead wires has to be connected to LED circuit that facies Lead wire Red to Red marking side And put the Lead wires into Lead wire holder Terminal block Red marking Controller s Lead wire red Lead wire h...

Page 12: ...nit s Lead wire black into Lead wire holder of outside Support unit s Lead wires orange yellow into Lead wire holder of inside Controller Support unit s Lead wire orange Support unit s Lead wire black Insulated connector Connect Insulated connector to Switch terminal 2 while keeping it away from Boss Support unit s Lead wire yellow Put Controller into the above illustrated position Switch terminal...

Page 13: ...eath Black Makita logo side Name plate side Motor housing Grip R Controller Power supply cord LED Circuit Support unit Blue Lead wire is used for some countries Brown Lead wire is used for some countries Switch Connector of Conroller Connector of LED Red Fig D 1B Blue Lead wire is used for some countries P 13 27 ...

Page 14: ...h to Terminal block Switch lever Connector of Controller The extra portion of Controller s thin Lead wires black red to be connected to LED has to be put in this position Connector of Controller s lead wires has to be connected to LED circuit facing Lead wire Red to Red marking side And put the Lead wires into Lead wire holder Terminal block Wiring in Motor housing on Grip R side Switch side Conne...

Page 15: ...as follows Support unit s Lead wire black into Lead wire holder of outside Support unit s Lead wire orange into Lead wire holder of inside Controller Support unit s Lead wire orange Support unit s Lead wire black Put Controller into the above illustrated position RP2300FC with LED Job Light Electronic Control Insulated connector Connect Insulated connector to Switch terminal 2 while keeping it awa...

Page 16: ...or some countries Black Makita logo side Name plate side Motor housing Grip R Power supply circuit Power supply cord LED Circuit Support unit Choke coil Switch Connector of Conroller Connector of LED Yellow Red Fig D 1C Brown Lead wire is used for some countries Blue Lead wire is used for some countries Blue Lead wire is used for some countries P 16 27 ...

Page 17: ...ecting Switch to Terminal block Switch lever The extra portion of Controller s thin Lead wires black red to be connected to LED has to be put in this position Connector of Controller s lead wires has to be connected to LED circuit facing Lead wire Red to Red marking side And put the Lead wires into Lead wire holder Terminal block Lead wire holder Connector of controller Red marking Controller s Le...

Page 18: ...llows Support unit s Lead wire black into Lead wire holder of outside Support unit s Lead wires orange yellow into Lead wire holder of inside Power supply circuit Support unit s Lead wire orange Support unit s Lead wire black Insulated connector Wiring in Grip R Connect Insulated connector to Switch terminal 2 while keeping it away from Boss Support unit s Lead wire yellow Put Power supply circuit...

Page 19: ...es sheath Black Makita logo side Name plate side Motor housing Grip R Power supply cord Support unit Choke coil Switch Yellow Fig D 1D Blue Lead wire be used for some countries Brown Lead wire be for some countries Noise Suppressor Noise suppressor is not used for some countries P 19 27 ...

Page 20: ...or s thin Lead wire white has to be put under the following Lead wires Support unit s lead wire black Thick Connecting lead wire purple for connecting Switch to Terminal block Switch lever Terminal block Connecting lad wires yellow orange purple to be connected to Switch in Grip R Fig D 2D Noise suppressor Wiring in Motor housing on Grip R side Switch side P 20 27 ...

Page 21: ...wires into Lead wire holders put them as follows Support unit s Lead wire black into Lead wire holder of outside Support unit s Lead wires orange yellow into Lead wire holder of inside Support unit s Lead wire orange Support unit s Lead wire black Insulated connector Connect Insulated connector to Switch terminal 2 while keeping it away from Boss Support unit s Lead wire yellow Switch terminal 2 B...

Page 22: ...ta logo side Name plate side Motor housing Grip R Power supply circuit Power supply cord LED circuit Support unit Blue Lead wire is used for some countries Blue Lead wire is used for some countries Brown Lead wire is used for some countries Switch Connector of Conroller Connector of LED Red Fig D 1E P 22 27 ...

Page 23: ...the Lead wires into Lead wire holder Lead wire holder Terminal block Red marking Controller s Lead wire red Wiring in Motor housing on Grip R side Switch side Connecting lead wires orange purple to be connected to Switch in Grip R Fig D 2E When putting Lead wires for connecting to Terminal block into this Lead wire holder thin Lead wire purple of Power supply circuit has to be put under the follow...

Page 24: ...Lead wire black into Lead wire holder of outside Support unit s Lead wire orange into Lead wire holder of inside Power supply circuit Support unit s Lead wire orange Support unit s Lead wire black Put Power supply circuit into the above illustrated position Wiring in Grip R RP1800F with LED Job Light Insulated connector Connect Insulated connector to Switch terminal 2 keeping it away from the Boss...

Page 25: ...sheath Noise suppressor is not used for some countries Black Makita logo side Name plate side Motor housing Grip R Power supply cord Support unit Switch Fig D 1F Blue Lead wire is used for some countries Brown Lead wire is used for some countries Noise suppressor P 25 27 ...

Page 26: ...in Lead wire white has to be put under the following Lead wires Support unit s lead wire black Thick Connecting lead wire purple for connecting Switch to Terminal block Switch lever Terminal block Wiring in Motor housing on Grip R side Switch side Connecting lead wires orange purple to be connected to Switch in Grip R Fig D 2F Noise suppressor P 26 27 ...

Page 27: ...ders put them as follows Support unit s Lead wire black into Lead wire holder of outside Support unit s Lead wire orange into Lead wire holder of inside Support unit s lead wire orange Support unit s lead wire black Wiring in Grip R RP1800 Insulated connector Connect Insulated connector to Switch terminal 2 while keeping it away from Boss Switch terminal 2 Boss P 27 27 ...

Reviews: