background image

PA

C

K

A

G

ED

TE

R

M

IN

A

L

A

IR

C

O

N

D

IT

IO

N

ER

S

PACKAGED TERMINAL 

AIR CONDITIONERS

Ultra-quiet operation is the hallmark of LG’s new line of PTAC products. Low decibel levels and outstanding
sound prevention rating make this your best choice for a quiet environment. And with efficiency ratings up
to 12.5 EER, these units are also your energy efficient choice. 

Other features include standard connections for remote thermostat and front desk controls. Gold Fin

technology protects the unit from the corrosive effects of outside air and extends the operating life of PTAC
models. And the industry standard size makes installation easy and economical.

7,000 –15,000 BTUs

Floor Standing

Ceiling Cassette

Type

A/C
A/C
A/C
A/C

System #

LF300CP
LF480CP
LC240CP
LC340CP

Pipe size

Liquid Suction

3/8"

5/8"

3/8"

3/4"

1/4"

1/2"

1/4"

5/8"

BTUs

24,000
44,000
24,000
34,000

Additional

Refrigerant

0.32 oz./ft.
0.42 oz./ft.
0.32 oz./ft.
0.42 oz./ft.

Max. length 

each pipe

100'
131'
100'
115'

Max.

elevation

66'
82'
50'
66'

Refrigerant Line Specifications

Each system is pre-charged with enough refrigerant to charge 25 ft. of line

and the interior unit. 

NOTE: Systems having the outdoor unit mounted above the indoor unit

(e.g. basement installations) have the following additional requirement:

For systems with maximum elevation of 25 ft. (see chart above and

Figure A), refrigerant lines must be oil trapped between 8 ft. and 16.4 ft.

of elevation.

For systems with elevation of greater than 25 ft. (see chart above),

refrigerant lines must be oil trapped at least every 16.4 ft. of elevation.

DUCT-FREE • FLOOR STANDING & CEILING CASSETTE • SINGLE ZONE

ELECTRICAL & REFRIGERATION 

QUICK REFERENCE

25' maximum

8' minimum

16.4' maximum

OIL TRAP

INDOOR UNIT

OUTDOOR UNIT

Figure A. Example: 25 ft. maximum
elevation. 

Floor Standing

Ceiling Cassette

Type

A/C
A/C
A/C
A/C

System #

LF300CP
LF480CP
LC240CP
LC340CP

Indoor

Outdoor

230/208

230/208

230/208

230/208

230/208

230/208

230/208

230/208

Voltage

BTUs

24,000
44,000
24,000
34,000

Rated 

Amps

11.5/11.5
20.0/20.0
11.5/12.4
11.5/16.5

MCA* 

20
30
20
30

MOP** 

30
40
30
40

Electrical Specifications

Digital Control Panel

Manual Control Panel

Wireless Digital

Thermostat

*Minimum Circuit Ampacity

**Maximum Overcurrent Protection 

Wire Size

Minimum wiring requirements suggested by manufacturer.

Minimum AWG 

14-3

Indoor/Outdoor Connecting Cable Minimum AWG 14-3

NOTE: Please see local electrical codes for
proper wire specifications.

All equipment single phase.

29

30

QUIETEST

IN THE

INDUSTRY

*

LG PTAC

SYSTEMS

*Tested by Independent 3rd Party
(Cerami & Associates Inc., Jan. 2007)

Summary of Contents for LP070CED-Y8

Page 1: ...lso your energy efficient choice Other features include standard connections for remote thermostat and front desk controls Gold Fin technology protects the unit from the corrosive effects of outside air and extends the operating life of PTAC models And the industry standard size makes installation easy and economical 7 000 15 000 BTUs Digital Control Panel Manual Control Panel Wireless Digital The...

Page 2: ...ndustry while also promoting the highest level of energy efficiency Digital Control Models Only Freeze Room Protection Electronic temperature controls constantly monitor and maintain indoor temperature to prevent freezing Ventilation Filter Polymeric mesh filter allows clean fresh air into the living space Ideal for Health Care applications Emergency Heat Heat Pump Models Only Bypasses compressor ...

Page 3: ...Compressor Energy efficient and maintenance free operation Sensors 4 Sensors provide highly efficient operation and maximizes guest comfort Power Cord Included with every unit Ceramic Heater Even stable and safe heating platform Wireless Energy Management Digital Thermostat with occupancy sensor Digital Touch Screen Controls Built In Occupancy Sensor Built In Energy Management Controls True Wirele...

Page 4: ...5 300 390 355 390 355 Fan Speeds Cooling Heating Fan 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Dehumidification pts hr 2 0 2 6 3 3 4 4 2 0 2 6 3 3 4 4 Indoor dB A 45 43 45 43 49 47 49 47 45 43 45 43 49 47 49 47 Outdoor dB A 60 58 60 58 63 61 63 61 60 58 60 58 63 61 63 61 STC 30 30 30 30 30 30 30 30 Electrical Rated Voltage 230 208 60 1 230 208 60 1 230 208 60 1 230 208 60 1 230 208 60 1 230 ...

Page 5: ...n Speeds Cooling Heating Fan 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Dehumidification pts hr 2 0 2 6 3 3 4 4 4 4 2 0 2 6 3 3 4 4 4 4 Indoor dB A 45 43 45 43 49 47 49 47 49 47 45 43 45 43 49 47 49 47 49 47 Outdoor dB A 60 58 60 58 63 61 63 61 63 61 60 58 60 58 63 61 63 61 63 61 STC 30 30 30 30 30 30 30 30 30 30 Electrical Rated Voltage 265 60 1 265 60 1 265 60 1 265 60 1 265 60 ...

Page 6: ...peeds Cooling Heating Fan 2 2 2 2 2 2 2 2 2 2 2 2 Dehumidification pts hr 2 5 3 2 2 5 3 2 Indoor dB A 56 54 58 56 56 54 58 56 Outdoor dB A 60 59 63 61 60 59 63 61 STC 30 30 30 30 Electrical Rated Voltage 230 208 60 1 230 208 60 1 230 208 60 1 230 208 60 1 Electric Heater kW 3 5 3 5 3 5 3 5 Circuit Breaker A 20 20 20 20 Dimensions 42 x 42 x 42 x 42 x W x H x D inches 16 x 16 x 16 x 16 x 19 7 8 19 7...

Page 7: ...t Digital Thermostat Control Board Snaps directly on to PTAC control board no tools required This innovative thermostat provides a great way to control spiralling energy costs while ensuring perfect comfort It combines the energy saving convenience of complete programmability and temperature control for both occupied and unoccupied rooms Its unique occupancy sensor automatically turns off the air ...

Page 8: ...densate Drain Kit AYDR101 Lateral Duct Kit AYLD1A Leveling Legs AYLL101 Control Panel Key Lock AYCP101 Remote Escutcheon Kit 10 Pack AYRE110 Replacement Filter 10 Pack AYFT110 Hydronic Steam Heat Coil Kit 230 208V PYHSK1A Hydronic Steam Heat Coil Kit 265V PYHSK2A Hydronic Valve 230 208V NC 1 2 PYHV1A Hydronic Valve 265V NC 1 2 PYHV2A Steam Valve 230 208V NC 1 2 PYSV1A Steam Valve 265V NC 1 2 PYSV2...

Page 9: ... Lateral Duct Kit AYLD1A Installation Quick Reference CFM Heating BTUs Hydronic Steam 270 300 335 355 390 420 14 500 15 500 16 500 17 000 17 500 18 500 18 500 19 500 21 000 21 500 22 000 23 500 Based on ARI test condition of 70º F DB 60º F WB 200º F EWT 20º F DT 70º F EAT 2 psig steam 70º F EWT Hydronic Valve Steam Valve PYHV1A 230 208V PYSV1A 230 208V PYHV2A 265V PYSV2A 265V Hydronic Steam Heat C...

Reviews: