background image

15W Class LED Module

User Manual

Model : 

LLDMWW0-15K902A

Summary of Contents for LLDMWW0-15K902A

Page 1: ...15W Class LED Module User Manual Model LLDMWW0 15K902A ...

Page 2: ...n 2 3 LED Module Instruction Manual 10 4 Applications 11 5 Warranty 12 6 Ordering Information 13 Appendix A Derived Models 14 Appendix B LED Package Properties 15 A di C Th l M t 17 Appendix C Thermal Management 17 Appendix D Module applied with asymmetry Lens Instruction Guide 21 ...

Page 3: ...hanical requirements for proper operation of the module Before forcing to operate the LED modules with a convertor LED module specifications such as Forward Voltage and Current should be considered Furthermore how many LED modules are being used what is total voltage what is total current and how the modules are connected series or parallel should be considered to choose a proper convertor are con...

Page 4: ...Size mm Φ76 5 11 9T Material RoHS Compliance Halogen Free Life Time hr 50 000 Warranty up to 50 000 IP IP67 Standards EN 62031 62471 UL 8750 CE UL Models in the Appendix A are measured to determine all values above with input current 500mA All values above are measured by the Integrating Sphere of LG Innotek with EC1000S WT210 All optic values are measured at 10 2sec in the Integrating Sphere The ...

Page 5: ... H 135 V 60 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 1000 6500 72 550 1055 600 1100 650 M 1150 650 Max 1150 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 3 ...

Page 6: ... V 70 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 900 6500 72 550 950 600 990 650 M 1020 650 Max 1020 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 4 ...

Page 7: ... H 130 V 130 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 1000 6500 72 550 1055 600 1100 650 M 1150 650 Max 1150 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 5 ...

Page 8: ...130 V 130 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 1000 6500 72 550 1055 600 1100 650 M 1150 650 Max 1150 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 6 ...

Page 9: ...115 V 115 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 1100 6500 72 550 1180 600 1250 650 M 1300 650 Max 1300 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 7 ...

Page 10: ...30 V 30 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 1100 6500 72 550 1180 600 1250 650 M 1300 650 Max 1300 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 8 ...

Page 11: ...20 V 20 If mA Luminance lm CCT K CRI Table 1 Luminance values depending on Input Current 500 1100 6500 72 550 1180 600 1250 650 M 1300 650 Max 1300 All Values Tc 65ºC Values measured by KTR 2011 5 All values can have tolerances in the range of 5 caused by Measuring Instruments KTR Korea Testing Research Institute Public Approval Institution 9 ...

Page 12: ...al energy from the LED module should be tightly attached on the module so that the module temperature especially at Tc can keep the condition lower than 70 C A heat sink combined with the LED module should not be directly mounted on the perfectly insulated ceiling or wall since it is hard to radiate the heat caused by the LED module The heat from the LED module must disperse to the surroundings in...

Page 13: ...4 Applications 11 ...

Page 14: ...nty claims should be made in writing according to LG Innotek procedures Valid warranty claims must be made within the warranty period 5 years and submitted within seven days of discovery of the damage or defect Field labor repair dismantle or installation charges are NOT included with this warranty Any unauthorized return repair replacement or modification of the Module shall void this warranty Th...

Page 15: ...rcle 30ºC F Type V Circle 20ºC G Connector JWPF waterproof Connector JST Mfg Co Ltd U No connector N Cable Length 100mm each LS cable Co Ltd 10 200mm each 20 400mm each 40 Product Name CCT Lens Connector Cable Length Eagle eye CW B U 10 Ex LED Module with Type III lens Connector 100mm cable 6500K PKG Eagle eye CW B U 10 Red Color Not available Developing now in progress Red Color Not available Dev...

Page 16: ...Model Name Remarks Type II LLDMWW0 15K901A Type III LRD01 11J4A LLDMWW0 15K902A Base Model 6500K Type V Sq 130 LLDMWW0 15K903A Type V 130 LLDMWW0 15K904A Type V 115 LLDMWW0 15K905A Type V 30 LLDMWW0 15K906A Type V 20 LLDMWW0 15K907A 2 Model Dimension 14 ...

Page 17: ...e Junction to Solder Point ºC W 6 75 Viewing Angle Degrees 125 Temperature Coefficient of voltage mV ºC 2 1 ESD Classification HBM per Mil Std 883D Class 2 DC Forward Current mA 1500 Reverse Voltage V 5 Forward Voltage 350mA V 3 0 3 75 Forward Voltage 700mA V 3 2 Forward Voltage 1000mA V 3 3 LED Junction Temperature ºC 150 3 LED PKG Characteristic Curve Figure 1 Relative Luminous Flux vs Current F...

Page 18: ...KG on the Metal PCB is recommended as shown Figure 10 CCT 6530K 510K Figure 3 Chromaticity Region for ANSI Cool White PKG M R M P1 P1 P1 P1 P2 P2 P2 P2 P2 P2 PKG A 1A 1B 1B 1A 1S 1T 1B 1A 1C 1D Table1 The Order of Priority for PKG M R M PKG A 1A 1B 1B 1A 1S 1T 1B 1A 1C 1D PKG B 1D 1C 1D 1C 1U 1R 1U 1T 1R 1S P1 The First Order of Priority for PKG M R M P2 The Second Order of Priority for PKG M R M ...

Page 19: ...D module cannot be guaranteed if operated without a heat sink The heat sink should be coupled with the module for thermal management as shown in Figure 9 Design of the heat sink is one of the main factor which determines lifetime and performance of the module Hest sink should be designed to keep the module temperature Tc under 70 C Recommended material for the heat sink is metals such as Aluminum ...

Page 20: ...lue of the Tj Since it is hard to measure Junction Temperature Tj at firsthand the value of the Tj can be assumed by the equation shown in Figure 11 on the next page Case Temperature Tc Case Temperature Tc is the temperature at the center point of the module plate remarked in Figure 10 It shows how to measure Tc Case Temperature Tc should be lower than 70ºC while the LED module is operating Therma...

Page 21: ... Thermal Pad Tj Tc Ptotal x Rjc Tj Figure8 Temperature of the Module at each position How to obtain the value of Tj when Tc is measured at 50 Basic Equation Tj Tc Ptotal x Rjc Ptotal Typical Input Current x Forward Voltage 0 5 A x 24 0 V 12 0 W Ptotal Typical Input Current x Forward Voltage 0 5 A x 24 0 V 12 0 W Rjc 1 6 W The value of Thermal Resistance is obtained by LGIT internal experiment Æ ex...

Page 22: ...74 071 1000mA 85 85 105 74 773 Reliability test result of PKG Current at 350mA Fi 9 L i Fl VS Ti Fi 10 R l ti Fl VS J ti T LED Module Thermal Specifications Parameter Min T pical Ma Unit Remarks Figure 9 Luminous Flux VS Time Figure10 Relative Flux VS Junction Temp Parameter Min Typical Max Unit Remarks Tj 90 105 Tc 70 Rjc 1 6 W L70 50 000 Hours 20 ...

Page 23: ...nses Therefore intended light distribution should be considered before attaching the LED module on a heatsink or luminaire As shown below Figure 14 the LED module with type III lens should be mounted correctly in the right direction on the luminaire in order to obtain suitable light distribution on the roadway X Ο X Ο Figure 7 Light distribution on the road surface depending on the LED Module dire...