Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS www lg solar com Installation manual PV Solar MODULE LGXXXN1C W E6 LGXXXN1K E6 LGXXXN1T E6 ...

Page 2: ...onnection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 13 Mechanical Installation methods Bolting Clamp Information Unloading Flow Guide 14 16 17 APPE...

Page 3: ...ed modules must be treated with safety protection equipment Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junction box cable It may occur spark or electric shock Do not bending junction box s cable While under stress it may occur module damage Cable ben...

Page 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Page 5: ...icro fiber cloth can be used for regular washing or It may result in a burn or injury Do not disassemble the solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Do ...

Page 6: ... connections Modules may be connected in series and or parallel to achieve the desired electrical output as long as it sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables etc...

Page 7: ...rks should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and location of grounding holes is provided in Product One M4 stainless steel bolt one nut one spring washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts wash...

Page 8: ...e that there is no shadowing affected by building chimney tree and neighboring module etc Mounting Rails No of Cell Do not use module to replace or partly replace roofs and walls of living places Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it faces the sun directly The tilt angle of the modules...

Page 9: ...ch module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting holes is provided in Product Tighten the bolt securely by using the combination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanic...

Page 10: ...he environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance either to the shop where you purchased the product or contact your local government waste office for details of your nearest authorized WEEE collection point For the mo...

Page 11: ... 18 5 18 5 18 5 18 5 18 5 18 5 18 5 18 5 18 5 18 5 LG360N1C W E6 360 0 3 19 20 1000 1768 1042 40 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO...

Page 12: ... Voltage Vmpp V 31 9 MPP Current Impp A 8 17 Open Circuit Voltage Voc V 38 3 Short Circuit Current Isc A 8 56 350 264 32 1 8 24 38 4 8 66 355 268 32 3 8 30 38 6 8 74 360 272 32 5 8 38 38 7 8 84 365 276 32 6 8 44 38 9 8 92 NMOT Nominal Module Operating Temperature Irradiance 800W m ambient temperature 20 wind speed 1m s 2 LGXXXN1T E6 Model 360 355 365 370 380 385 Maximum Power Pmax W MPP Voltage Vm...

Page 13: ...13 Dimensions of Modules 60Cell Module Unit mm in LGXXXN1C W E6 LGXXXN1K E6 LGXXXN1T E6 Frame Cross section Note Cable length with connector MC4 05 8 PV CO02 Long Frame Short Frame ...

Page 14: ...Rear Pa Position mm 240 440 5400 4000 Load Front Rear Pa Position mm 234 or 334 5400 4000 Load Front Rear Pa Position mm 240 440 5400 4000 Load Front Rear Pa Position mm 0 300 5400 2400 Load Front Rear Pa Position mm 0 50 0 650 2400 2400 A B Fig 3 Clamping Type Note All mechanical installation methods and bolting method in this appendix were not tested by CSA or 3rd party It is evaluated by LG int...

Page 15: ... Pa Position mm 0 50 0 650 2400 2400 A B Load Front Rear Pa Position mm 240 440 4000 4000 Fig 7 Clamping Type Fig 8 Clamping Type Fig 9 Clamping Type APPENDIX Mechanical Installation 60Cell Model 15 Note All mechanical installation methods and bolting method in this appendix were not tested by CSA or 3rd party It is evaluated by LG internal test 240 440 ...

Page 16: ... are recommended per solar module Bolting Method Clamp system requirements Clamp width 40mm 1 57in Clamp height compliant with a 40mm 1 57in frame height Clamp depth 8 10mm 0 31 0 39in The clamp should not be touched with the module s glass Use corrosion resistant material clamps and hardware Ifyouuseaspecialclamp itneedstotestforcompatibilitybyLGE Use appropriate bolted connections as per clamp m...

Page 17: ... Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging A minimum of two o...

Page 18: ...ea Contact solarinfo lge com http www lg solar com LG Electronics Deutschland GmbH Alfred Herrhausen Allee 3 5 65760 Eschborn Germany Contact service solar lge de LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...