background image

C O P Y R I G H T   ©  2 0 0 7   L G   E L E C T R O N I C S   U S A   I N C ,   A L L   R I G H T S   R E S E R V E D .

LG IrisAccess™ 4000: iCAM4100 Quick Start Guide
The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by LG Electronics USA 

Incorporated. LG Electronics USA Incorporated assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this document.
Please remember that existing images or drawings that you may want to include in your document may be protected under copyright law. The unauthorized incorporation of such material 

into your work could be a violation of the rights of the copyright owner. Please be sure to obtain any permission required from the copyright owner.
LG, LG Iris, the LG logo, LG Iris logo and IrisAccess are either registered trademarks or trademarks of LG Electronics Incorporated in the United States and/or other countries.
LG Electronics USA Incorporated, Iris Technology Division. 7 Clarke Drive, Cranbury, New Jersey 08512, USA.
Document Number: DV002Q502 (07/07)

FOR MODEL NUMBERS:

iCAM4100
iCAM4100R
iCAM4101
iCAM4101R
iCAM4110-E1
iCAM4110R-E1
iCAM4110-H1
iCAM4110R-H1
iCAM4111-E1
iCAM4111R-E1
iCAM4111-H1
iCAM4111R-H1

Quick Start Guide

Summary of Contents for IrisAccess iCAM4100

Page 1: ...t you may want to include in your document may be protected under copyright law The unauthorized incorporation of such material into your work could be a violation of the rights of the copyright owner Please be sure to obtain any permission required from the copyright owner LG LG Iris the LG logo LG Iris logo and IrisAccess are either registered trademarks or trademarks of LG Electronics Incorpora...

Page 2: ...AC 1 5AMP 50 60Hz Output 12V DC 5 0AMP Power Cable for 110V CAT5 Ethernet Cable Quick Start Guide Security Screw Wrench Required Equipment not included with iCAM4100 Server Computer refer to the Hardware Manual for details Ethernet Switch Ethernet Wiring Uninterruptible Power Supply ...

Page 3: ...iCAM can be used in enrollment mode using the IrisEnroll application included with EAC software or recognition mode when it is configured for use with an ICU The iCAM can not easily be switched between enrollment and recognition modes once configured The iCAM can be wall mounted or used with an optional desk top stand 2 iCAM4100 in the IrisAccess System Network Switch ICU DCU Ethernet Door Control...

Page 4: ...ncluding the Ethernet network must be powered through Uninterruptible Power Supplies UPS UPS must provide power line filtering as well as power back up operation Each IrisAccess system component on the Ethernet network system must have a unique manually assigned IP address The iCAM4100 requires at least the following wires Ethernet network wiring to connect with the network switch to communicate t...

Page 5: ...allation plate on the desired wall near the secured door and mark the holes as the figure below illustrates The recommended height from the floor to bottom of unit is 140cm 55 however installation height can be adjusted depending on average height of users 5 In case of recessed mounting leave 6mm 1 4 of extra space above the marked hole when mounting the installation plate to allow the iCAM to sli...

Page 6: ...6 4801 156 15 16 6 6 49 5 Hole 6 45 29 16 2 7 6 2 2 139 208 Dimensions and Screw Holes in the Installation Plate mm unit Dimensions of iCAM4100 mm unit Installation Plate 80 62 8 35 5 217 235 5 1 208 2 2 11 4 Rotation Part with Front Enclosure ...

Page 7: ...AM through the Smart Card or Wiegand In connections Refer to the 4000 Hardware Manual for connection details Note Only the smart card serial and Wiegand input interfaces are active with the current iCAM versions Note The iCAM4110 H1 iCAM4111 H1 and the iCAM4110 E1 iCAM4111 E1 are supplied with a smart card reader already wired and installed 12 Close the front cover and gently slide the cover downw...

Page 8: ...r which supports graphics ex Internet Explorer can be used to configure the iCAM4000 4100 1 Set the computer to the static IP of 192 168 5 1 subnet 255 255 255 0 2 Open the web browser and enter http 192 168 5 100 in the address bar then press ENTER The iCAM login screen will appear 3 Enter the default Username iCAM4000 and Password iris4000 both are case sensitive 4 The iCAM Configuration Main Me...

Page 9: ...ress is on a different subnet the web browser will display the standard The page cannot be displayed message To test the IP Address change perform a ping to the new IP Address 1 Click on Start in the Windows task bar 2 Select Run 3 Type cmd 4 Press Enter 5 At the command prompt type ping new IP ex ping 192 168 5 120 6 Close the command prompt window If changing the IP Address to multiple iCAMs Not...

Page 10: ...all cards with this key enrollment and will only be able to read cards with this key verification To configure the smart card key log into the iCAM configuration interface see Changing the IP Address of the iCAM in section 6 From the main menu select SmartCard Configuration Leave the Serial Port selection as Serial Port 2 Select the Smart Card Type HID iClass iCAM4010 H1 MIFARE or Smart ID iCAM401...

Page 11: ...rt Additional information and Technical assistance is available on the LG Electronics Iris Technology Division s support web site at www lgiris com click on Support Service then Technical Support 10 Technical Support ...