background image

Instruction Manual 

 
 
 
 
 
 
 
 
 
 
 
  

 

 

 

 

 

 

 

 

Part NO. 383EW5N001T(MFL30049915) 

Model Numbers  

DT6101SAU

 

DT6101SSA

 

Summary of Contents for DT6101SAU

Page 1: ...Instruction Manual Part NO 383EW5N001T MFL30049915 Model Numbers DT6101SAU DT6101SSA ...

Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 7 MAINTENANCE 8 ...

Page 3: ...f the burner is equipped with an enclosed non removable cover and all country specific regulations are observed This restriction do se not apply to gas cookers and gas hobs Regulations concerning the discharge of air have to be fulfilled USE The extractor hood has been designed exclusively for household use to eliminate kitchen smells Never use the hood for purposes other than for which it has bee...

Page 4: ...ight Blower Filters 8 1 Directional Air Outlet grille 9 1 Flange ø 150 mm 10a 1 Reducer Flange ø 150 120 mm 10b 1 Damper 20 1 Closing element Ref Q ty Installation Components 12a 4 Screws 3 5 x 16 12e 2 Screws 2 9 x 12 7 12f 5 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 9 1 12a 20 12f 10a 12e 8 10b ...

Page 5: ...nected the relative fas tening elements Close the sliding suction panel again Insert the Hood until the snap on side sup ports click into place fig 4 Open the sliding suction panel Lock in position by tightening the screws Vf from underneath the Hood fig 4 If necessary adjust the whole filter holder unit and proceed as follows Loosen the four adjustment screws Vr and close the sliding panel again ...

Page 6: ...rcoal filters ø 120 10b 9 10a ø 150 10b 9 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 155 mm in the wall unit over the hood Insert the flange 9 on the hood body outlet Connect the hood body outlet to the top part of the wall unit using a rigid or flexible pipe ø 150 mm to be selected by the installer Fix the pipe in position using sufficient pipe clamps not supplied Fix the directional grille 8 ...

Page 7: ...Switches the lighting system on and off M Motor Switches the extractor motor on and off 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions thanks to an op timum relation between hood performance and noise 3 Maximum speed suitable when the highest cooking vapour emission has to be eliminated for longe...

Page 8: ...LTERS These filters are not washable and cannot be regenerated and must be replaced approximately every four months or more frequently by particularly heavy use Pull out the sliding suction panel Remove the grease filters Remove the saturated carbon filter by releasing the fixing hooks Replace the grease filters Close the sliding suction panel Light Replacement 20 W Halogen lamp Remove the metal t...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...436003255_ver2 ...