background image

P/No.: 3828A20114D

Printed in Korea

P/No.:3828A20091C

Printed in China

①DHB-1260PL-표지영어  2003.10.24 3:7 PM  페이지1

Summary of Contents for DHB1260PL

Page 1: ...P No 3828A20114D Printed in Korea P No 3828A20091C Printed in China DHB 1260PL 표지영어 2003 10 243 7PM 페이지1 ...

Page 2: ...website http www lgservice com Thank you for purchasing this unit This manual is arranged to get you started easily Please read all instructions before using Retain this for future reference Convenient and Energy Saving DHB 1260PL 표지영어 2003 10 243 7PM 페이지2 ...

Page 3: ...e Conversion 11 SPOT Dry 12 Laundry Dry Continuous Auto Swing 13 Defrost Operation FULL Mark 14 Operating the TIMER 15 Removing Collected Water 16 Continuous Drainage 17 Normal Maintenance Long term Storage 18 Troubleshooting Before you call for service 19 20 Prior to Use Operating Instructions How to Use Eff i c i e n t l y ...

Page 4: ...l damage may occur WARNING Connect the Power Plug completely to an AC Outlet Dust or incomplete connection may cause electric shock or fire Do not turn off the Dehumidifier by pulling out the power cord Electric shock or fire may occur Do not connect the power cord in the line or do not use an extension cord Electric shock overheating or fire may occur Do not damage Power Cord Do not put heavy thi...

Page 5: ...anty period Do not place the Dehumidifier near gas or electric burner This may cause deformation due to incomplete combustion or heat Do not put a pet or house plant where it will be exposed to direct airflow This may harm the pet or plant When abnormal burning smell etc unplug the Power Cord Running the unit under abnormal condition may cause problems electric shock or fire Refer servicing to you...

Page 6: ...dren and seniors Do not use for other purposes Never use to maintain precision machine tableware or art work It may lower its quality Ventilate from time to time Be careful especially when using with gas or electric burner If ventilation is incomplete oxygen may lack When unplugging the Power Cord hold the plug body If you pull the cord the line may be cut off which may cause fire When cleaning yo...

Page 7: ... cause electric shock or leakage of electricity Place the unit on a level flat floor with a stable horizontal surface If floor is unstable vibration or noise may occur Besides inclining the unit may cause malfunction Stop performing Continuous Drain if the temperature around drain hose becomes below 0 C Water inside the hose may be frozen which cause wetting furniture Do not turn the handle around...

Page 8: ... Rear Rear Rear Rear Rear Bucket Cover Bucket Handle Float Check if the water in the bucket is full Bucket Contains water that was dehumidified Sensor Part Do not block Display Outlet Louver Do not close when operating the unit ON OFF Water Level Indicator Caster Handle When moving the unit make the handle in an upright position Continuous Drain Hole Air Inlet Air Filter Hose Cover Hose Air Purify...

Page 9: ...ting continuously or stopping the function Under continuous operation dehumidifying occurs irrespective of humidity of the room Spot Dry Button Mode Button Each time that the Mode button is pressed the mode is shifted Automatic Dehumidification Quiet Operation Prevent Moisture condensation Air Purifying In the sequence above lamp lights up ON OFF Button To turn the Dehumidifier on and off Timer Bu...

Page 10: ...ht will come on Defrosting Lamp Airflow Indicating Lamp Indicates airflow AUTO Swing Lamp Indicates Louver is swinging Quiet Operation Lamp Dehumidifies in Low Fan speed Prevention Moisture Condensation Lamp Prevention Moisture condensation when room temperature decreases Spot Dry Lamp Air Purifying Lamp It removes room odor and clean air Humidity Indicating Lamp Laundry Dry Continuous Operation L...

Page 11: ...bout 3 minutes to protect compressor When the Dehumidifier start running the noise increases Operate at room temperature between 1 40 C Over 20cm Over 20cm Over 20cm Set the direction of air flow by using Louver Press the Auto Swing Button to adjust air flow direction To stop operation press ON OFF Button once more Louver gets closed ON Indicator Lamp will light off Mode Button can be used to conv...

Page 12: ...en cigarette smoking pollen or bad odor contaminated the air Air Filter makes air clean At this time dehumidification will not work Air Purifying To maintain clean air Maintain humidity Setting by controlling the dehumidification and air flow For about 2 minutes after the Dehumidifier starts operation dehumidification starts irrespective of the humidity of the room If humidity in the room gets bel...

Page 13: ...nsion hose This may cause the Dehumidifier to fall off resulting in injury When the hose is not long enough use extension hose COMP may stop for protect products in the case of using SPOT DRY function in the area where voltage is unstable Take the hose to the direction at which drying is desired Open the Hose Cover Take out the hose of the Dehumidifier Extension Hose Hose ...

Page 14: ...ntinuous Button Laundry Dry Continuous Lamp comes on Louver may stop temporarily due to location adjustment but will start to move in a moment When hands or objects touch Louver consequently changing rotating angle restart Swing operation If you stop operation in AUTO Swing mode next time when starting the unit AUTO Swing mode will be selected To stop AUTO Swing operation press the AUTO Swing butt...

Page 15: ...epending on room temperature at the most Operating the TIMER Operating the TIMER Empty the bucket and reset the time When the bucket gets full of water during TIMER operation FULL indicator will light up and fanning will stop Be sure to check if the unit is running Press the TIMER button Since TIMER converts in the following sequence select the time setting 1 hour interval For every hour the resid...

Page 16: ...ion FULL Sensor will activate so the Dehumidifier will not run Bucket Handle Bucket Handle Immediately after stopping the unit take the bucket out The water remaining in the cooling coils may fall to the inside of the unit Wipe dripped water with soft cloth After taking the bucket out do not touch any parts inside the unit The Sensor that detects Water FULL may not function well Rinse the inside o...

Page 17: ...side Plug the hose into the drain While pressing Stopper insert 15 mm hose inner diameter into continuous drainage hole Make sure that there are no water leaks Replace the bucket properly If the bucket is not placed the unit will not run FULL indicating sensor will operate and the Dehumidifier will stop running How to connect hose when making continuous drainage 1 Drain the water 2 Make the handle...

Page 18: ...hen filtering effect disappear replace it Air Filter Deodorizing Air Purifying Filter Pin Clean the air filter When the white side back side gets brown or blackened clean it Install the air filter Push the handle until tick sound is heard Attach the Deodorizing Air Purifying Filter to the air filter The Deodorizing Air Purifying Filter is disposed after use Filter life varies depending on the plac...

Page 19: ...year Check periodically Check if power cord is too hot Check if power cord is damaged Sponge etc Float If water remains in the Float the AUTO SHUT OFF switch may not work properly so wipes water completely Soft Cloth CAUTION Unplug the Power Cord from AC outlet Remove water in the bucket completely After removing the lid of the bucket wipe the water inside the bucket Let the filter dry for about 6...

Page 20: ...ot contact laundry Area to be dehumidified is too large There is too much laundry Operation and stop repeats alternately Humidity may be automatically controlled by AUTO dehumiditied Mode Water leaks The Dehumidifier may have been skewed or fallen down During continuous drainage hose connection has been incomplete or detached During Operation Mode Dehumidifier does not dry the air as it should Doo...

Page 21: ...Depending on the angle of Louver the volume of noise changes During operation startup operation conversion or operation stop a weird sound is heard in the unit Until coolant circulation gets stabilized the sound of coolant may be heard Compressor will not work For 3 minutes immediately after the unit is turned off or Power Cord is plugged the unit will not operate to protect the compressor If the ...

Reviews: