Summary of Contents for Washer/Dryer

Page 1: ...Installation Instructions Laundry Center Washer l Dryer 240 Volt ...

Page 2: ...nce may be connected directly to the fused disconnecl or circuit breaker box through flexible armored or non metallic sheathed 10 gauge copper cable It IS the personal responsibility and obligation of the customer to contact a qualified installer lo assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA 70 1967 and local codes and ordi...

Page 3: ...th of the exhaust system depends upon the type of duct used number of elbows and type of exhaust hood The maximum lenglh for both ngid and flexible duct is shown in charf Caution Exhaust Systems longer than speclfled WIII l Shorten the life of the dryer l Reduce performance cause longer drying times and Increase energy usage l Accumulate Ilnt Now start 1 Use a IS Inch socket wrench to remove two b...

Page 4: ...he washer lb Open iasher lid Latch under Ihe dryer will hold lid open Pull three straps with completely out of wa Numbers correspond to steps PANEL C 10 Read label Firmly jerk then pull one of the three shipping straps up until strap with key is co nplelely removed horn washer Repeat for other two shipping straps Put straps in the same area as rear corner shipping pieces r 11 Remove label Take hos...

Page 5: ...round free end of drain hose lo make a hook shape Before atlachmg water Inlet hoses run waler through both laucets IO get rid of particles in waler lines Ihat might clog hoses Met valves are plastic d strip or crossthread 20 Atiach botiom hose inlet marked H lo hot waler taucel Attach top hose inlet marked C lo cold wale1 faucet Tighten couplings lo faucet by hand then use pliers to make fmal two ...

Page 6: ...RECT ELECTRICAL SUPPLY AND RECOMMENDED GROUNDING METHOD Check the installation inslructlons to see that you have completed each step Complete any missed steps before you continue Check that all parts are now installed See parts list Panel A If there is an extra part go back through steps to see which step Check that you removed all the shipping pieces including the three shipping straps with keys ...

Page 7: ...upply cord from the termmal block 3 Use a screwdnver to slide the strain rehe clip away from the power supply cord See Figure 5 4 Pull downward on the power supply cord until it IS removed from the dryer 7 Figure 5 away trdm power supply cord Pull out power supply cord Toconnect Plain wire ends I Strip outer covering back 3 inches irom the end exposing the 3 wires 2 Strip the insulation back 1 inc...

Page 8: ...l copper power supply cable and strain relief 3 Remove the grounding wire green from the internal grounding connector and fasten under center silver colored terminal block screw 4 Connect the neutral wire of the flexible armored or non metallic sheathed copper power supply cable to the center silver colored terminal screw oi the terminal block Connect the other wires to the Outer terminals See Fig...

Page 9: ... This appliance is manufactured with the neutral terminal connected to the frame PANEL G Replace lermitw Mock cover ...

Page 10: ...s must use the minimum dimensions indicated To prevent large amounts of lint and moisture from accumulating and to maintain drying efficiency this appliance must be exhausted outdoors Recessed non exhausted InstslWon must use only ths msr erhsud poslUon and Exhaust Dsfktor LCK4500 ie mqulred Washer l r Front View exhausted all spsclng csn tm 0 Closet Door Closet Door 1 46 sq In f i 14eq in f Front...