background image

GP-61OA/GP-61OD 

G P - I B  A D A P T E R 

INSTRUCTION MANUAL 

KENWOOD CORPORATION 

Summary of Contents for GP-610A

Page 1: ...GP 61OA GP 61OD G P I B A D A P T E R INSTRUCTION MANUAL KENWOOD CORPORATION ...

Page 2: ...a 1 i n s t a l l a t i o n This equipment generates uses and can r a d i a t e radio frequency energy and i f no t i n s t a 1 led and used in accordance with the instructions may cause harmful interference to radio communicat ions However there i s no guarantee that interference w i l l not occur in a part icular i n s t a l l a t ion I f this equipment does cause harmful interference to radio o...

Page 3: ...nd listen only mode setting 1 4 3 Trans i t ion to the local state 1 5 4 Transition to the remote state 1 5 2 Connect ion of the Control led Power Supply 1 6 1 Connecting GP G10D with PD power supply 1 6 2 Connecting GP 610A with PA power supply 1 7 3 Analog output connect ion 1 9 4 Digital I O connection 2 0 3 Code Format Setting 2 2 4 Total System Adjustment 2 8 7 PROGRAM A P P L I C A T I O N E...

Page 4: ... adapter can convert the digital signal from the GP IB bus into the analog signal by using three mutually insulated D As and obtain three independent analog signal outputs The voltage or current of up to three PD or PA series power supplies can be controlled Since tow channel 12 bit resolution and one channel 8 bit resolution are used on the D A converter high accuracy set t ing can be done WARNIN...

Page 5: ...led power supply OVP operation c i r c u i t breaker o f f PD power supply only or power switch off Control led power supply CC CV state change Analog output A B channel C channel Output voltage range 0 to 10 V bipolar 0 to 10 V monopolar Full scale voltage 1 Q y H Q y variable range Maximum output current 3 mA D A converter resolution 12 bit 0 05 4 8 mV 8 bit 0 4 39 mV Monotony 8 bits Monotony 8 ...

Page 6: ...less Insulation dielectric strength Between GP 1B connector outputs 500 VAC for 1 minute Analog output A B C Between analog output Same as above Between the output and case Same as above Between the input power supply and case 1 kVAC for 1 minute Between the input power supply and output Same as above Insulation resistance Between the input power supply and case 30 megohms or more at 500 VDC Betwe...

Page 7: ...um size Weight Approximately 2 3 kg Accessor ies CP 610A Instruct ion manual 1 Replacement fuse 2 OP 15 1 r 3 pin DIN 2 pin cable 2 7 pin DIN 6 pin cable CP 610D Instruction manual 1 Replacement fuse 2 OP 14 1 r 3 pin DIN 3 arrow type terminal cable 2 7 pin DIN 7 pin DIN cable 1 ...

Page 8: ...o not use the component at a place where i s much dust and vibration I f a noise source exists near the component take the proper action Before power on Complete connect ions before power on and check that the connect ions are correct Power on off order should be as shown below Do not replace the connector while power i s on GP 610A GP 610D This component Controlled power supply OFF Be sure to gro...

Page 9: ...l use Connect the short bar between the terminal and GND or remove i t as shown at right Use in the master slave mode power supply on the slave Be sure to remove the short bar Output ripple noise When this component i s connected to the controlled power supply the output ripple noise of the stabilized DC power supply may increase compared with the output ripple noise of the independent s t a b i l...

Page 10: ... data passes through the photo isolator and i s insulated Data i s converted into parallel data by the shift register and fed to the D A converter The analog output of the D A converter passes through the re lay and is output This relay performs switching over remote and local In addition the CPU controls the control connector and processes SRQ 4 SYSTEM CONFIGURATION Block diagram GP IB connector ...

Page 11: ...D power supply only 1 contact in OUTPUT A Local signal setting analog singal 4 Local setting signal input PD power supply only 1 contact in OUTPUT B Local signal setting analog singal 4 Local setting signal input PD power supply only 1 contact in OUTPUT C Local signal setting analog singal 2 Details of control by this component to a power supply Control item Voltage only Current only Both vol tage...

Page 12: ...icat i on I f the serial number i s the following or larger modification i s not needed 3 Model to be connected Models that can be connected are as follows Rated full scale voltage V Rated ful 1 sea 1e current A P D 8 2 0 8 2 0 P D 8 2 0 D 8 2 0 P D 8 3 0 8 3 0 P D 8 3 0 D 8 3 0 P D 1 8 1 0 1 8 1 0 P D 1 8 1 0 D 1 8 1 0 P D 1 8 2 0 1 8 2 0 P D 1 8 2 0 D 1 8 2 0 P D 1 8 3 0 1 8 3 0 P D 1 8 3 0 D 1 ...

Page 13: ...is LED i s on during operation D LCL Remote local changeover switch Non lock type If this switch i s pressed in remote mode operating with GP IB the local mode i s set and the power supply i s operated from the front panel PD series power supply only 1 0 Front panel Rear panel Note The figure shows GP 610A ...

Page 14: ...ta are being transferred SRO This LED indicates the service request mode It is on while SRQ i s generated on the GP IB bus CH A FS COARSE Channel A output voltage coarse adjustment semi fixed variable resistor 15 turns CH A FS FINE Channel A output voltage fine adjustment semi fixed variable resistor 1 turn CH A OV Channel A output offset adjustment semi fixed variable resistor CH B FS COARSE Chan...

Page 15: ...DIN connector I t supplies the output setting analog signal to the power supply connected OUTPUT C Channel C analog output DIN connector 11 supplies the output setting analog signal to the power supply connected CONTROL A Channel A digital control DIN connector In outputs the OUTPUT switch control signal and outputs the interrupt signal CONTROL B Channel B digital control DIN connector In outputs ...

Page 16: ...and the listen only mode are set GND terminal SIGNAL Signal grounding to which the circuit ground i s connected FRAME Frame grounding to which the case is connected Be sure to perform grounding to secure safety and to prevent malfunctions due to external noise 1 3 ...

Page 17: ...e securely onto the GP IB connector of this component 2 Address and Iisten only mode sett ing The address of this component on the GP IB bus and the 1isten only mode are set by using the address switch 8 bit DIP switch on the rear of this component Unused Normally OFF Listen only mode sett ing swi tch Address set t ing swi tch Sett ing example 01100 address 12 The address is set with binary number...

Page 18: ...er supply changes from the remote mode to the local mode and operat ion on the panel i s allowed PA power supply By switching the CV CC external control switch S1 S2 on the rear of the PA power supply from REMOTE to LOCAL the local mode of the PA power supply i s set and operat ion on the panel i s allowed If OP 13 i s not used switch external r e s i s t o r S2 S4 to LOCAL at the same time 4 Tran...

Page 19: ...ear view of the PD series OUTPUT A OUTPUT B 3 pin DIN connector 3 pin DIN connector OUTPUT C Constant current setting Remove the short bar Constant voltage setting Connected to the 7 pin DIN connector on the rear of the PD series 1 6 CONTROL A CONTROL B i 7 pin DIN connector Black Red White Black Red White OP 12 ...

Page 20: ...ER SLAVE CP IB LOCAL REMOTE Red Black Red Black Black SRQ Orange Blue Red BrownI OUTPUT Yellow Note When CV CC is externally controlled by mounting 0P 13 on the PA power supply be sure to set the voltage current setting variable resister on the panel of the power supply to maxi mum 1 7 3 pin DIN connector OUTPUT A OUTPUT B OUTPUT C CONTROL A C V C C PARALLEL OPERATE ...

Page 21: ...PARALLEL OPERATE Red Black Note By s e t t i n g S 2 S 4 to REMOTE and attaching a 10 kiloohm external r e s i s t o r external CV CC control only becomes possible However the voltage current cannot be set on the pane 1 of the power supply C V REMOTE C C REMOTE OUTPUT Red Black OUTPUT A OUTPUT B OUTPUT C COTROL A COTROL B 1 8 ...

Page 22: ...f the controlled power supply External noise may cause malfunctions Analog output Output voltage Analog input PD reference voltage OUTPUT A pin 2 3 0 1 0 V 11 b i t 0 1 0 V 11 b i t 1 0 1 0 V 12 b i t pin 1 0 10V Voltage current setting reference voltage OUTPUT B pin 2 3 0 1 0 V 11 b i t 0 1 0 V 11 b i t 1 0 1 0 V 12 b i t pin 1 0 10V Voltage current setting reference voltage OUTPUT C pin 2 3 0 1 ...

Page 23: ... external voltage of the PA series instruct ion manual 4 Digital I O connect ion The d i g i t a l 1 0 connector 7 pin DIN of this component inputs a pair of interrupt signals and output the OUTPUT ON OFF control signal If an interrupt occurs service request SRQ is generated for the GP IB bus Also the status byte i s sent corresponding to serial polling Interrupt signal input OUTPUT ON OFF signal ...

Page 24: ...es CONTROL A or 1 cv tT PA power supply 2 1 GP 610D Tl in DIN CONTROL A or I TPin DIN PD power supply OP 12 OUTPUT ON OFF CV tT POWER ON OFF GP 610A TPin DIN OUTPUT ON III F Brown Ye I low Black Blue POWER OR OFF Orange Red ...

Page 25: ...ers are converted into ASCII codes and output to the GP IB bus 1 GP IB Input Code Format 1 Delimiter There are three demiliters for the input code r CR LF CR LF EOI EOI 2 Status byte MSB Indicates occurrence of SRQ Input syntax error 97 61H 1 0 0 0 0 1 Input setting error 98 62H 1 0 0 0 1 0 Breaker off 100 C6410 1 0 0 1 0 0 Transition to CC operation 104 6811 1 0 1 0 0 0 Transition to CV operation...

Page 26: ...ower supply 1 to 3 digits including decimal point Example 8 V 8 1 2 A 1 2 36V 36 3 A 3 110V M 10 20A 20 P Bipolar output 10 to 10 V excluding channel 0 Q Monopolar output 0 to 10 V V Voltage specified A Current speci f ied A Channel A specified B Channel B specified C Channel C specified If any other setting is done SRQ occurs ...

Page 27: ... V 6 00 or 6 14 75V M 75 0 50V 0 50 or 5 1 20A 1 20 or 1 2 3 00 A 3 00 or 3 0 50A 0 50 or 5 h output polari ty specified omissible output polarity specified V Voltage specified A Current specified A Channel A specified B Channel B specified C Channel C specified Note I f the control led power supply is not set before this code is input SRQ occurs ...

Page 28: ...nel B specified Note I f the GP IB address command GET is executed output can be turned on at the same time for both channel A and B Note Before control 1ing the output switch turn on the output switch of the PD PA power supply 6 Service request If an abnormal command i s sent or an error occurs on PD PA when the PD PA series power supply is control led by using this component service request SRQ ...

Page 29: ...CC operation Operation of the controlled power supply changes from the CV mode to CC mode 5 Transition to CV operation Operation of the controlled power supply changes from the CC mode to CV mode SRQ masking command Masking factors a Breaker off 100 b Transition to CC operation 104 c Transition to CV operation 88 Masking command CHMS1 Masks the SRQ cause a b or c for control channel A B CHMS2 Mask...

Page 30: ...ponent accepts the cause and generates SRQ 5 SRQ cause for transition to CV operation This component accepts the cause and generates SRQ 2 Listen only mode 1 SRQ cause for the input syntax error This component accepts the cause and i s initialized 2 SRQ cause for the input sett ing error This component accepts the cause and i s initialized 3 SRQ cause for breaker off T h i s component does not acc...

Page 31: ...inutes Offset adjustment The full scale voltage current output corresponding to the controlled power supply i s set from the GP IB bus Full scale adjustment is done by using the FS semi solid variable resistor on the panel of GP 610A D For output A and B the COARSE coarse adjustment and FINE fine adjustment VRs are provided for ful 1 scale adjustment When channel A is used use VR on the panel When...

Page 32: ...ndicates the lowest digit in units of 100 mV in f u l l s c a l e ind icat ion Therefore when a voltage which i s 20 V or less i s set and the lowest digit i s indicated in units of 10 mV after full scale adjustment the voltage set from the c o n t r o l l e r may d i f f e r by several d i g i t s from power supply indication on these models Note When the PA series i s controlled by this componen...

Page 33: ... 20 PRINT H7 CHAVQ36 Control led power supply specified CHAVQ36 Control led power supply specified 30 PRINT H7 CHBAQ20 J 40 PRINT II7 CHBA10 Limiting current setting 50 PRINT H7 CHAG OUTPUT ON 60 G0SUB10000 70 PRINT II7 CHAV10 Output voltage setting 10 V output 80 G0SUB10000 90 PRINT H7 CHAV36 Output voltage setting 36 V output 100 END 1000 REM WAIT 1010 FOR T 0 TO 1000 NEXT Interval time setting ...

Page 34: ...35 20 PD18 20 Note Set the CURRENT dial of the ncccs ssary value 10 REM SAMPLE 2 20 PRINT H7 CHAVQ36 Control led power supply specified 30 PRINT H7 CHBVQ18 J 40 WBYTE H27 1I8 OUTPUT ON GET sending 50 G0SUB10000 60 PRINT H7 CHAV18 PD35 20 18 V setting 70 G0SUB10000 80 PRINTOUT CHBV18 PD18 20 18 V setting 90 G0SUB10000 100 PRINT AH7 CHAV36 PD35 20 36 V setting 120 END 1000 REM WAIT 1010 FOR T 0 TO 1...

Page 35: ...ol led power supply specified 50 PRINT H7 CHBAQIO 60 PRINT H7 CHAV1 Recharging current sett ing 70 PRINT H7 CHAV12 Recharging complet ing voltage sett ing 80 PRINT H7 CHAG Recharging start 90 SRQ ON 100 IF SRQ 1 GOTO120 110 IF SRQ 2 GOTO 150 ELSE 100 120 PRINT 117 CHAC Recharging stop 130 PRINT BATTERY CHARGE END 140 END 150 PRINT H7 CHAC 160 PRINT PD18 10 EMERGENCY 170 END 1000 REM SRQ CHECK 1010...

Page 36: ... case Remove the case after power i s turned off and the power cord i s removed from the outlet D By us ing a Phi 1ips screwdr ivcr remove two screws on the top of the case and six screws on the sides of the case Pul1 up the case 3 3 ...

Page 37: ...n the case and change the connectors P4 5 6 and fuse on the GP IB unit X81 1630 00 in the component as shown below Note Before the change remove the AC plug from the out let Rated input voltage 100V I00V 100V 100 V P6 Swi tching Fuse 0 7A 0 7A 0 4 A 0 4 A 3 4 P4 P5 ...

Page 38: ...9 EXTERNAL VIEW 3 5 ...

Page 39: ...TING O N THE RACK MOUNT ADAPTER GP 610A RK 604J MS RK 604E EIA GP 610D RK 601 JIS EIA This component can be mounted on the rack mount adapter shown above For detaiIs contact your dealer or our distributer 3 6 ...

Page 40: ...A product of KENWOOD CORPORATION 1 7 5 2 c h o m e S h i b u y a S h i b u y a k u T o k y o 150 J a p a n B 6 3 0 0 4 8 0 0 ...

Reviews: