background image

 

 

Operator s manual 

  

A-Line Air Scrubber  

 

 

Please read the operator’s manual carefully and make sure you understand the instructions before using 

the machine.

 

US 

 

 

 

 

A 600, A 1200

Summary of Contents for A 600

Page 1: ...Operator s manual A Line Air Scrubber Please read the operator s manual carefully and make sure you understand the instructions before using the machine US A 600 A 1200 ...

Page 2: ...ations or has been used in ways other than those outlined in this instruction manual Before using the machine please read the safety regulations carefully Read the complete instruction manual before using the Husqvarna A 600 A 1200 All spare parts used for the Husqvarna A 600 A 1200 must those specified by Husqvarna Construction Products Type plate CHINA CHINA Unpacking When unpacking the machine ...

Page 3: ...ty equipment to use and how to work in a safe mode Warning Cables damaged through crushing or splitting can be dangerous if used and should be replaced immediately Risk of personal injury Warning Do not connect the machine to an unearthed socket Risk of personal injury Warning Make sure the assembly area is firm so the air scrubber does not tip over Risk of personal and material injury Stop button...

Page 4: ...t the lead to the power outlet attach the outlet hose if available Start the machine by pressing the start knob The air scrubber has two speeds The air scrubber separates material in two stages The first stage uses a coarse filter This traps the bigger particles and acts as protection for the main filter The coarse filter should be changed on a daily basis The second absolute filter separates the ...

Page 5: ... can be spread when cleaning the coarse filter and during filter change Accordingly the user should wear protective glasses protective gloves and a breathing mask conforming to protection class FFP2 Accessories PART NO DESCRIPTION No machine Machine 590430001 Pre filter 20 pcs 1 ea A 600 590460801 HEPA filter 1 ea A 600 590430002 Pre filter 20 pcs 1 ea A 1200 590463201 HEPA filter 1 ea A 1200 Cont...

Page 6: ...ly Wrong fuse Connect the correct fuse The fan runs Blocked filter Change filter but suction is poor Cover loose Adjust Sealing defect Change current seal Dust blows from unit Defective or loose filter Adjust or change Abnormal noise Order service Keep these instructions TECHNICAL DATA Air scrubber A 600 A 1200 Power 0 385 kW 0 5 HP 0 585 kW 0 8 HP Voltage 120 120 V Current 3 2 A 4 9 A Power suppl...

Page 7: ..._ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ...

Page 8: ...www husqvarnacp com Original instructions 1158768 95 2017 04 26 ...