hp AlphaServer DS15 

Series 10000 Rackmount Installation Guide 

Order Number:  EK-D1510-RM. B01 

This Guide is for service providers and self-maintenance customers who 
are installing an AlphaServer DS15 system into the 10000-series cabinet. 

Hewlett-Packard Company 

 

 

Summary of Contents for StorageWorks 1000 - Modular Smart Array

Page 1: ...0000 Rackmount Installation Guide Order Number EK D1510 RM B01 This Guide is for service providers and self maintenance customers who are installing an AlphaServer DS15 system into the 10000 series cabinet Hewlett Packard Company ...

Page 2: ...s A devices are those that may reasonably be expected to be installed in a business or commercial environment Class B devices are those that may reasonably be expected to be installed in a residential environment i e personal computers The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the us...

Page 3: ... relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help Declaration of Conformity for products marked with the FCC logo United States only This device complies with Part 15 of the FCC...

Page 4: ...g two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Canadian Notice Avis Canadien Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numérique de la classe A respecte toutes les e...

Page 5: ... R TTE Directive 1999 5 EC Compliance with these directives implies conformity to the following European Norms in parentheses are the equivalent international standards and regulations EN55022 CISPR 22 Electromagnetic Interference EN55024 IEC61000 4 2 3 4 5 6 8 11 Electromagnetic Immunity EN61000 3 2 IEC61000 3 2 Power Line Harmonics EN61000 3 3 IEC61000 3 3 Power Line Flicker EN60950 IEC60950 Pro...

Page 6: ......

Page 7: ... and Secure the AlphaServer DS15 1 6 1 8 Check Power and Secure Cables 1 7 1 9 For More Information 1 8 Index Examples Figures Figure 1 1 Unpacking the Rackmount Kit 1 2 Figure 1 2 Rack Bracket Location on the Rails 1 3 Figure 1 3 Installing the Rack Brackets 1 4 Figure 1 4 Attaching the Rackmount Ears 1 5 Figure 1 5 Inserting and Securing the Unit 1 6 Figure 1 6 Securing Power 1 8 Tables Table 1 ...

Page 8: ...viii ...

Page 9: ...itions This manual has 1 chapter Chapter 1 Rackmount Installation Instructions for installing the DS15 AlphaServer into a rack system Documentation Titles Table 1 HP AlphaServer DS15 Documentation Title Order Number hp AlphaServer DS15 and AlphaStation DS15 Owner s Guide EK DS150 OG hp AlphaServer DS15 and AlphaStation DS15 Service Guide EK DS150 SG hp AlphaServer DS15 Series 10000 Rackmount PDU I...

Page 10: ...x ...

Page 11: ... prevent injury access is limited to persons who have appropriate technical training and experience Such persons are expected to understand the hazards of working within this equipment and take measures to minimize danger to themselves or others 1 2 Rackmount Guidelines The hp AlphaServer DS15 is a three U unit and the PDU used is one U in size This allows for a maximum of 13 systems in a 10000 Se...

Page 12: ...hen installed in the rack Base zero should be the horizontal centerline between the two square openings that are closest to each other on the vertical rack rail If you are adding your AlphaServer DS15 to a rack already populated with other units then base zero is near the top of the unit that will be underneath the AlphaServer DS15 you are installing Each AlphaServer DS15 needs a clearance of 9 ho...

Page 13: ...ng Bracket Left side Rack Bracket Locating Tab in front Locating Tab in front Locating Tab in front Locating Tab in front Locating Tab in front U nut on Mounting Bracket 3U Left Rail Rear Rack Rail Front Rack Rail MR0275C NOTE Space must be left for a PDU which is installed on the bottom of the rack DS15 Rackmount Installation Guide 1 3 ...

Page 14: ...ghtly toward the rear of the rack X Pull the bracket forward and in toward the side of the cabinet aligning the shorter front tabs into their corresponding openings in the front rack rail Y 2 Use two screws to secure the front of each bracket to the front rack rail 3 Repeat these procedures to install the other bracket in the exact same position on the other side of the rack Figure 1 3 Installing ...

Page 15: ...ted on the front edge of the system with the three holes on the rackmount ears see Figure 1 4 2 Using a Phillips screwdriver screw the ears onto the system Do not apply excessive force Figure 1 4 Attaching the Rackmount Ears MR0551 DS15 Rackmount Installation Guide 1 5 ...

Page 16: ...rver DS15 into the cabinet by fastening the right and left front rackmount ears Figure 1 5 Inserting and Securing the Unit MR0554A Caution During removal system box not tethered Attention Pendant le déplacement le boîtier système n est pas fixé Precaución Durante el traslado no debe atarse la caja del sistema Achtung Beim Entfernen ist das Systemgehäuse nicht gesichert PK1037 99 1 6 Series 10000 R...

Page 17: ...3 Route the power cord over the back of the rail into the cabinet side area 4 Continue cabling When all cabling is complete connect power cord Z to the power controller unit 5 To hold the power cord connector tightly in place move the power cord bracket over the rear of the power cord connector and tighten the attached screw Y DS15 Rackmount Installation Guide 1 7 ...

Page 18: ...gure 1 6 Securing Power MR0553B 1 2 3 4 1 9 For More Information Using a Web browser you can access additional documentation at http h18003 www1 hp com alphaserver 1 8 Series 10000 Rackmount Installation ...