background image

 

HP 5930-4Slot Fan Trays (JH185A & JH186A) User Guide-APW100

BOM: 3101A0JE     Part Number: 5998-7154

2

1

When you install a fan tray, make sure the "TOP" sign is on the top surface of the fan tray.

The HP 5930-4Slot Back to Front Airflow Fan Tray provides forward airflow from the 
power module side to the port side. The HP 5930-4Slot Front to Back Airflow Fan Tray
provides reverse airflow from the port side to the power module side. The two fan trays 
feature small size, fast heat dissipation, and hot swapping. They can adjust the fan 
speed automatically. 

Overview  

!

Views  

HP 5930-4Slot Back to 

Front Airflow Fan Tray

Handle (blue)

Alarm LED

Handle (red)

HP 5930-4Slot Front to 

Back Airflow Fan Tray

Alarm LED

Specification 

Item 

HP 5930-4Slot Back to Front Airflow Fan Tray: 

From the power module side to the port side

Fans

Airflow direction 

Max fan speed 

Max airflow 

Max power consumption 

Voltage 

Operating temperature 

Operating humidity 

Storage temperature 

Storage humidity 

1, 80 × 80 × 76 mm (3.15 × 3.15 × 2.99 in)

HP 5930-4Slot Front to Back Airflow Fan Tray: 

From the port side to the power module side

20000 R.P.M

120 CFM

57 W

12 V

0°C to 45°C (32°F to 113°F)

5% to 95% (non condensing)

–40°C to +70°C (–40°F to +158°F)

5% to 95% (non condensing)

Alarm LED for the fan trays 

Description 

Status 

Off 

The fan tray is operating correctly. 

A problem has occurred on the fan tray. 

On 

 Installing or removing a fan tray 

The installation and removal procedures are the same for the HP 5930-4Slot Back to 
Front Airflow Fan Tray and the HP 5930-4Slot Front to Back Airflow Fan Tray.

Alias

Product code

HP description 

HP 5930-4Slot Front to Back 
Airflow Fan Tray

HP 5930-4Slot Front (Port Side) to Back 
(Power Side) Airflow Fan Tray

JH186A

HP 5930-4Slot Back to Front 
Airflow Fan Tray

JH185A

HP 5930-4Slot Back (Power Side) to Front 
(Port Side) Airflow Fan Tray

Specifications for the fan trays  

Reviews: