background image

 
 

HP 3330B/3570A 

 

NETWORK ANALYZER 

 

SOFTWARE MANUAL 

 
 

 

 
 
 

Software and Manual by:  
 
John Barnes 
(905) 873 1087 

Summary of Contents for 3330B

Page 1: ...HP 3330B 3570A NETWORK ANALYZER SOFTWARE MANUAL Software and Manual by John Barnes 905 873 1087 ...

Page 2: ...n be plotted on a pen plotter or plot files can be generated for including in reports Additional features include the storing and displaying of reference sweeps Equipment required HP 3330B Frequency synthesizer HP 3570A Network analyzer HP 11236 Multi Unit Cable HP 11235 HPIB adapter Two 50 ohm bnc cables HP 82335 A B HPIB interface card or National Instruments GPIB II IIA card IBM compatible pc a...

Page 3: ...FFF If the config sys file contains an EMM386 statement the following should be added DEVICE EMM386 EXE X DC00 DFFF This to prevent memory conflict between the memory manager and the interface card No drivers are required for the HP card all the software is contained within the program National Instruments GPIB II IIA card Set the dip switches as follows PC II 7210 A9 1 A8 0 A7 1 A6 1 A5 0 A4 0 A3...

Page 4: ...be obtained from the National Instruments website I used version 2 6 from www ni com The drivers must be installed The following line is added to the config sys file DEVICE C GPIB PC GPIB COM The system is then re booted From the GPIB PC directory run IBCONF This is an interface board configuration utility Addjust the settings to like these shown below Scroll down and finish the settings ...

Page 5: ...ting the Instruments The RF connection is optional The output of the 3330B can be routed to the rear alt Output Triaxial connector or to the front panel This depends on the internal wiring of the 3330B Connect the 1MHz ref connectors using a bnc cable Connect the 20 33 MHz connector using a bnc cable Connect the Mult Unit cable via the HP 11235 adapter to the interface card in the computer The wir...

Page 6: ...et or BodeNI ret depending on the version being used The opening screen will appear Parameters can be changed selecting with the up down arrows and using page up and page down to modify the value F1 Pressing F1 will cause a log graph to be drawn on the screen The number of cycles depends on the Start and Stop Frequencies The Synthesizer is set to the Start Frequency and Level After 500ms the first...

Page 7: ...spaced between the Start and Stop Frequency The Steps parameter controls the number of steps F6 Pressing F6 allows the user to enter a title The following screen appears ...

Page 8: ... moves the cursor to the start of the title End move the cursor to the last character in the title Enter closes the Enter Title screen and display the title on the screen F2 Pressing F2 allows the user to store the current sweep in one of the reference memories The following screen appears The up down arrow keys are used to select the memory Pressing enter transfer the sweep to the memory and clos...

Page 9: ...sed on the current sweep The reference sweep can be turned off by selecting No reference display F7 Pressing F7 causes the current screen to be plotted on a plotter attached to the HPIB bus F8 Pressing F8 causes the current screen to be plotted to a file The file is automatically selected The first file will be plot1 plt The number is incremented as additional plots are made Programs such as PRINT...

Page 10: ...F10 Pressing F10 displays an about box Contacting the author The author can be contacted by email at jbarnes aztec net com ...

Page 11: ...PIB 1 A GND 18 24 2 DIO1 1 B DIO2 2 3 DIO3 3 C DIO4 4 4 DIO5 13 D DIO6 14 5 DIO7 15 E DIO8 16 6 REN 17 F DAV 6 7 NDAC 8 G NRFD 7 8 ATN 11 H IFC 9 9 SRQ 10 16 T Key Way V SHIELD 12 Not Connected EOI 5 Edge connector is 2 rows of 18 connections on 0 156 centers ...

Reviews: