background image

 

 

 

 

 

Microsoft Windows Event ID and SNMP Traps 

Reference Guide 

For use with SmartStart version 8.25 
 

Part number: 347870-009 
Ninth edition: June 2009 
 

 

Summary of Contents for 226824-001 - ProLiant - ML750

Page 1: ...Microsoft Windows Event ID and SNMP Traps Reference Guide For use with SmartStart version 8 25 Part number 347870 009 Ninth edition June 2009 ...

Page 2: ...uting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Confidential computer software Valid license from HP required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s sta...

Page 3: ...rs 3072 3876 21 Event Identifiers 4352 4626 25 Storage agents 29 Event Identifiers 256 774 29 Event Identifiers 1061 1098 32 Event Identifiers 1101 1199 38 Event Identifiers 1200 1294 64 Event Identifiers 1343 4613 77 Server agents 82 Event Identifiers 256 774 82 Event Identifiers 1024 1092 85 Event Identifiers 1103 1183 93 Event Identifiers 1539 3352 124 Event Identifiers 5632 5684 126 NIC agents...

Page 4: ...Insight Management events that are entered into the Microsoft Windows NT Event Log when they occur Values are 32 bit values laid out as follows 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 Sev C R Facility Code where Sev The severity code 00 Success 01 Informational 10 Warning 11 Error C The customer code flag R A reserved bit Facility...

Page 5: ...ee the HP website http www hp com For HP technical support In North America Call 1 800 HP INVENT 1 800 474 6836 This service is available 24 hours a day 7 days a week For continuous quality improvement calls may be recorded or monitored If you have purchased a Care Pack service upgrade call 1 800 633 3600 For more information about Care Packs see the HP website http www hp com Outside North Americ...

Page 6: ...ice Event Log Severity Warning 2 Log Message The Foundation Agents service could not set the service status with the Service Control Manager The data contains the error code Event identifier cpqhsmsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not create an event object The data contains the error code Event identifier cpqhsmsg dll 26...

Page 7: ... dll 268 Hex 0x8435010c Service Event Log Severity Warning 2 Log Message The Foundation Agents service detected an invalid state for agent 1 The data contains the state Event identifier cpqhsmsg dll 269 Hex 0x8435010d Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not stop agent 1 The data contains the error code Event identifier cpqhsmsg dll 270 Hex 0x8435010...

Page 8: ...00 Service Event Log Severity Warning 2 Log Message The Host Remote Alerter detected an invalid data type within an alert definition Event identifier cpqhsmsg dll 769 Hex 0x84350301 Service Event Log Severity Warning 2 Log Message The Host Remote Alerter detected an error while attempting to log an alert remotely The data contains the error code Event identifier cpqhsmsg dll 770 Hex 0x84350302 Ser...

Page 9: ...oGenericData NT Event ID 1106 Hex 0x44350452 cpqhsmsg dll Log Severity Information 1 Log Message 1 SNMP Trap cpqHo2AppErrorTrap 11004 in CPQHOST MIB Symptom An application has generated an exception Specific error information is contained in the variable cpqHoSwPerfAppErrorDesc Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqHoSwPerfAppErrorDesc Supporting SNMP Trap Description cpqHoSwPerfAppE...

Page 10: ...nerated this trap Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqMeAlarmVariable cpqMeAlarmSampleType cpqMeAlarmValue cpqMeAlarmFallingThreshold cpqMeAlarmOwner cpqMeAlarmSeverity cpqMeAlarmExtendedDescription Supporting SNMP Trap Description cpqMeAlarmOwner Variable cpqMeAlarmVariable has value cpqMeAlarmValue cpqMeAlarmFallingThreshold NT Event ID 1164 Hex 0x8435048c cpqhsmsg dll Log Severi...

Page 11: ...ap Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqMeAlarmVariable cpqMeAlarmSampleType cpqMeAlarmValue cpqMeAlarmFallingThreshold cpqMeAlarmOwner cpqMeAlarmSeverity cpqMeAlarmExtendedDescription Supporting SNMP Trap Description cpqMeAlarmOwner Variable cpqMeAlarmVariable has value cpqMeAlarmValue cpqMeAlarmFallingThreshold NT Event ID 1166 Hex 0x8435048e cpqhsmsg dll Log Severity Warning 2 Lo...

Page 12: ...k the resource for the cause of the failure Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqClusterResourceName Supporting SNMP Trap Description Cluster resource cpqClusterResourceName has failed NT Event ID 1169 Hex 0x84350491 cpqhsmsg dll Log Severity Warning 2 Log Message The cluster network 4 has become degraded SNMP Trap cpqClusterNetworkDegraded 15007 in CPQCLUS MIB Symptom This trap is ...

Page 13: ...the cause of the degraded condition Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqClusterNodeName Supporting SNMP Trap Description Cluster service on cpqClusterNodeName has become degraded NT Event ID 1172 Hex 0xc4350494 cpqhsmsg dll Log Severity Error 3 Log Message The cluster service on 4 has failed SNMP Trap cpqClusterNodeFailed 15004 in CPQCLUS MIB Symptom This trap is sent any time the ...

Page 14: ...ta sysName cpqHoTrapFlags cpqOsCpuIndex cpqOsCpuInstance cpqOsCpuTimePercent Supporting SNMP Trap Description The Processor performance Instance cpqOsCpuInstance is critical with Processor Time of cpqOsCpuTimePercent percent NT Event ID 1175 Hex 0x84350497 cpqhsmsg dll Log Severity Warning 2 Log Message The Cache Performance Instance 4 is degraded with Cache Copy Read Hits of 5 percent SNMP Trap c...

Page 15: ...le Usage of 5 percent SNMP Trap cpqOsPageFileUsageDegraded 19005 in CPQWINOS MIB Symptom The PagingFile Usage performance property is set to degraded Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqOsPagingFileIndex cpqOsPagingFileInstance cpqOsPageFileUsagePercent Supporting SNMP Trap Description The PagingFile performance instance cpqOsPagingFileInstance is degraded with PagingFile Usage of ...

Page 16: ... degraded with DiskBusyTime of cpqOsLogicalDiskBusyTimePercent percent NT Event ID 1180 Hex 0xc435049c cpqhsmsg dll Log Severity Error 3 Log Message The Logical Disk Performance Instance 4 is failed with Disk Busy Time of 5 percent SNMP Trap cpqOsLogicalDiskBusyTimeFailed 19008 in CPQWINOS MIB Symptom The LogicalDisk BusyTime performance property is set to critical Supporting SNMP Trap Data sysNam...

Page 17: ...ge Unable to load a required library This error can be caused by a corrupt or missing file Reinstalling the Management Agents or running the Emergency Repair procedure may correct this error Event identifier cpqhsmsg dll 1806 Hex 0x8435070e Service Event Log Severity Warning 2 Log Message The Foundation SNMP Agent service is not running The agent has determined that the Foundation Agents service i...

Page 18: ...he registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2053 Hex 0x84350805 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpq...

Page 19: ...nt Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqhsmsg dll 2307 Hex 0x84350903 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqhsmsg dll 2308 Hex 0x84350904 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not read the registry value 1 The data contains the error code Event...

Page 20: ... Event identifier cpqhsmsg dll 2317 Hex 0x8435090d Service Event Log Severity Warning 2 Log Message The Threshold Agent could not get the system type The data contains the error code Event identifier cpqhsmsg dll 2354 Hex 0x84350932 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not create an SNMP session The data contains the error code Event identifier cpqhsmsg dll 23...

Page 21: ...ey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3075 Hex 0x84350c03 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg d...

Page 22: ...Event Log Severity Warning 2 Log Message Could not write the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3843 Hex 0x84350f03 Service Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory con...

Page 23: ...1 Log Message Resource status is online Event identifier cpqhsmsg dll 3861 Hex 0x44350f15 Service Event Log Severity Information 1 Log Message Resource status is offline The resource has failed or was taken offline by a cluster administrator Event identifier cpqhsmsg dll 3862 Hex 0x44350f16 Service Event Log Severity Information 1 Log Message Could not get the resource status The Cluster service m...

Page 24: ...service Event identifier cpqhsmsg dll 3871 Hex 0x84350f1f Service Event Log Severity Warning 2 Log Message The Agent could not open the Cluster service registry key Event identifier cpqhsmsg dll 3872 Hex 0x84350f20 Service Event Log Severity Warning 2 Log Message The specified storage class is not supported by the Agent The Agent only supports the disk resource class Event identifier cpqhsmsg dll ...

Page 25: ...ntains the error code Event identifier cpqhsmsg dll 4356 Hex 0x84351104 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not read the registry value 1 The data contains the error code Event identifier cpqhsmsg dll 4357 Hex 0x84351105 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent found an incorrect type for registry value 1 The da...

Page 26: ...y Warning 2 Log Message The External Status MIB Agent could not get the system type The data contains the error code Event identifier cpqhsmsg dll 4402 Hex 0x84351132 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not create an SNMP session The data contains the error code Event identifier cpqhsmsg dll 4403 Hex 0x84351133 Service Event Log Severity Warning 2 L...

Page 27: ... Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 4612 Hex 0x84351204 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may corr...

Page 28: ...y not have started or may still be in the starting state Event identifier cpqhsmsg dll 4626 Hex 0x84351212 Service Event Log Severity Warning 2 Log Message The Agent failed to process the MOF file to get the data from WMI Problem with WMI service or MOF file or wrong file paths used ...

Page 29: ...vice Event Log Severity Warning 2 Log Message The Storage Agents service could not set the service status with the Service Control Manager The data contains the error code Event identifier cpqstmsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not create an event object The data contains the error code Event identifier cpqstmsg dll 261 Hex...

Page 30: ...sg dll 269 Hex 0x8435010d Service Event Log Severity Warning 2 Log Message The Storage Agents service could not stop agent 1 The data contains the error code Event identifier cpqstmsg dll 270 Hex 0x8435010e Service Event Log Severity Warning 2 Log Message The Storage Agents service could not terminate agent 1 The data contains the error code Event identifier cpqstmsg dll 271 Hex 0x8435010f Service...

Page 31: ...rror can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 515 Hex 0x84350203 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 516 Hex...

Page 32: ...Event identifier cpqstmsg dll 772 Hex 0xc4350304 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent detected a null handle on initialization The data contains the error code Event identifier cpqstmsg dll 773 Hex 0xc4350305 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent received an error on WaitForMultipleObjects call The data contains the error code Ev...

Page 33: ...status of a drive array logical drive The variable cpqDaLogDrvStatus indicates the current logical drive status Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaLogDrvStatus Supporting SNMP Trap Description Status is now cpqDaLogDrvStatus NT Event ID 1063 Hex 0xc4350427 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Spare Drive Status Change Log Message The spare drive in slot 4 po...

Page 34: ...oTrapFlags cpqDaPhyDrvStatus cpqDaPhyDrvCntlrIndex cpqDaPhyDrvBusNumber cpqDaPhyDrvBay cpqDaPhyDrvModel cpqDaPhyDrvFWRev cpqDaPhyDrvSerialNum cpqDaPhyDrvFailureCode Supporting SNMP Trap Description Physical Drive Status is now cpqDaPhyDrvStatus NT Event ID 1065 Hex 0xc4350429 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Accelerator Status Change Log Message The array accelerator board...

Page 35: ... data has been lost User Action Verify that no data has been lost Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaCntlrSlot cpqDaCntlrModel cpqDaAccelSerialNumber cpqDaAccelTotalMemory Supporting SNMP Trap Description Accelerator lost battery power Data Loss possible NT Event ID 1067 Hex 0xc435042b cpqstmsg dll Log Severity Error 3 Event Title Drive Array Accelerator Battery Failed Log Messa...

Page 36: ...ontroller in slot 4 SCSI has a new status of 2 SNMP Trap cpqScsi3LogDrvStatusChange 5021 in CPQSCSI MIB Symptom Logical Drive Statues Change The Storage Agent has detected a change in the status of a SCSI logical drive The current logical drive status is indicated in the cpqScsiLogDrvStatus variable Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqScsiLogDrvStatus cpqScsiLogDrvCntlrIndex cpqScs...

Page 37: ...s User Action If the fan status is degraded or failed replace any failed fans Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsBoxFanStatus Supporting SNMP Trap Description Storage System fan status changed to cpqSsBoxFanStatus NT Event ID 1076 Hex 0xc4350434 cpqstmsg dll Log Severity Error 3 Event Title Storage System Temperature Failure Log Message The 6 7 storage system connected to SCSI b...

Page 38: ... Trap Description Temp is outside of normal range NT Event ID 1078 Hex 0x44350436 cpqstmsg dll Log Severity Information 1 Event Title Storage System Temperature OK Log Message The temperature in the 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 has returned to the normal operating range SNMP Trap cpqSs3TempOk 8011 in CPQSTSYS MIB Symptom Storage System temperature OK The t...

Page 39: ...ace Log Message The side panel has been replaced on the 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 SNMP Trap cpqSs3SidePanelInPlace 8012 in CPQSTSYS MIB Symptom Storage System side panel is in place The side panel status has been set to in place The storage system s side panel has returned to a properly installed state User Action None Supporting SNMP Trap Data sysName ...

Page 40: ...atus is now cpqTapePhyDrvStatus NT Event ID 1119 Hex 0x8435045f cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Drive Head Needs Cleaning Log Message The tape drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 needs to have a cleaning tape inserted and run SNMP Trap cpqTape3PhyDrvCleaningRequired 5008 in CPQSCSI MIB Symptom Tape Drive Cleaning Required trap The ...

Page 41: ... MIB Symptom An IDE drive status has been set to degraded User Action The drive should be scheduled for replacement For detailed information on a component replacement see the appropriate Maintenance and Service Guide Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqIdeIdentIndex Supporting SNMP Trap Description IDE drive cpqIdeIdentIndex has become degraded NT Event ID 1122 Hex 0x44350462 cpqs...

Page 42: ...gDrvBoxIndex cpqFcaLogDrvIndex cpqFcaLogDrvStatus cpqFcaLogDrvOsName cpqFcaLogDrvFaultTol cpqFcaLogDrvSize Supporting SNMP Trap Description Status is now cpqFcaLogDrvStatus NT Event ID 1146 Hex 0xc435047a cpqstmsg dll Log Severity Error 3 Event Title External Array Physical Drive Status Change Log Message The physical drive in port 5 bay 6 on array 4 has a new status of 7 SNMP Trap cpqFca2PhyDrvSt...

Page 43: ...h this drive User Action If the spare drive status is failed replace the drive Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqFcaSpareBusNumber cpqFcaSpareBay cpqFcaSpareStatus Supporting SNMP Trap Description Spare Status is now cpqFcaSpareStatus on bus cpqFcaSpareBusNumber NT Event ID 1148 Hex 0xc435047c cpqstmsg dll Log Severity Error 3 Event Title Externa...

Page 44: ...d in the accelerator memory when the system lost power that data has been lost User Action Verify that no data has been lost Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqFcaAccelBoxIoSlot cpqFcaCntlrModel cpqFcaAccelSerialNumber cpqFcaAccelTotalMemory Supporting SNMP Trap Description Accelerator lost battery power Data Loss possible NT Event ID 1150 Hex 0xc...

Page 45: ...tus is offline 4 access to the storage box has been lost Check the storage box and all fibre channel connections for problems Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqFcaCntlrBoxIoSlot cpqFcaCntlrStatus cpqFcaCntlrModel cpqFcaCntlrSerialNumber cpqFcaAccelTotalMemory Supporting SNMP Trap Description Status is now cpqFcaCntlrStatus NT Event ID 1152 Hex 0x...

Page 46: ...r or replace the failed power supply Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqSsPowerSupplyBay cpqSsPowerSupplyStatus cpqSsPowerSupplySerialNumber cpqSsPowerSupplyBoardRevision cpqSsPowerSupplyFirmwareRevision Supporting SNMP Trap Description Storage system power supply status changed to cpqSsPowerSupplyStatus NT Event ID 1154 Hex 0x84350482 cpqstmsg dl...

Page 47: ...rent status User Action If the temperature status is degraded or failed shut down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqSsTempSensorLocation cpqSsTempSensorStatus cpqSsTempSensorCurrentValue Supporting SNMP...

Page 48: ...pe Library Degraded Log Message The SCSI tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 is in a degraded condition SNMP Trap cpqTape3LibraryDegraded 5012 in CPQSCSI MIB Symptom Tape Library Degraded The Insight Agent has detected that an autoloader unit is in a degraded condition Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqTapeLibrarySerialNumber Suppor...

Page 49: ...d NT Event ID 1161 Hex 0xc4350489 cpqstmsg dll Log Severity Error 3 Event Title SCSI CD Library Status Change Log Message The CD Library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a new status of 2 SNMP Trap cpqScsiCdLibraryStatusChange 5015 in CPQSCSI MIB Symptom CD Library Status Change The Insight Agent has detected a change in the status of a CD Library device T...

Page 50: ...NMP Trap cpqDaCntlrActive 3016 in CPQIDA MIB Symptom Controller Active This trap indicates that the agent has detected that a backup array controller in a duplexed pair has switched over to the active role The variable cpqDaCntlrSlot indicates the active controller slot and cpqDaCntlrPartnerSlot indicates the backup User Action Check the partner controller for problems If this was the result of a ...

Page 51: ...ndicates that the agent has detected a change in the status of a Fiber Channel Tape library The variable cpqFcTapeLibraryStatus indicates the current tape library status The variable cpqFcTapeLibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library is failed or is offline check the tape library front panel and all fibre channel connections Supporting SNMP Trap Da...

Page 52: ...dicates that the agent has detected a change in the status of a Fiber Channel Tape Drive The variable cpqFcTapeDriveStatus indicates the current tape status The variable cpqFcTapeDriveScsiTarget indicates the SCSI ID of the tape drive User Action If the tape is failed or is offline check the tape and all fibre channel connections Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqFcTapeCntlrWWN c...

Page 53: ...ed with a new cleaning tape Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqFcTapeCntlrWWN cpqFcTapeDriveScsiBus cpqFcTapeDriveScsiTarget cpqFcTapeDriveScsiLun Supporting SNMP Trap Description Cleaning tape needs replacing NT Event ID 1179 Hex 0x8435049b cpqstmsg dll Log Severity Warning 2 Event Title External Array Controller Active Log Message The external controller in I O slot 5 of array 4...

Page 54: ...ntlrIndex cpqDaTapeLibraryScsiBus cpqDaTapeLibraryScsiTarget cpqDaTapeLibraryScsiLun cpqDaTapeLibraryModel cpqDaTapeLibraryFWRev cpqDaTapeLibrarySerialNumber cpqDaTapeLibraryStatus Supporting SNMP Trap Description Status is now cpqDaTapeLibraryStatus for the tape library NT Event ID 1181 Hex 0x8435049d cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Library Door Status Change Log ...

Page 55: ...ons Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaTapeDrvCntlrIndex cpqDaTapeDrvBusIndex cpqDaTapeDrvScsiIdIndex cpqDaTapeDrvLunIndex cpqDaTapeDrvName cpqDaTapeDrvFwRev cpqDaTapeDrvSerialNumber cpqDaTapeDrvStatus Supporting SNMP Trap Description Status is now cpqDaTapeDrvStatus for a tape drive NT Event ID 1183 Hex 0x8435049f cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape...

Page 56: ...Log Severity Warning 2 Event Title Fibre Channel Controller Status Change Log Message The Fibre Channel Controller in slot 4 has a new status of 5 SNMP Trap cpqFca2HostCntlrStatusChange 16021 in CPQFCA MIB Symptom Fibre Channel Host Controller Status Change This trap indicates that the agent has detected a change in the status of a Fibre Channel Host Controller The variable cpqFcaHostCntlrStatus i...

Page 57: ...ty Warning 2 Event Title ATA RAID Logical Drive Status Change Log Message ATA RAID logical drive number 6 on the 5 in slot 4 has a new status of 2 SNMP Trap cpqIdeLogicalDriveStatusChange 14005 in CPQIDE MIB Symptom IDE Logical Drive Status Change This trap indicates that the agent has detected a change in the status of an IDE logical drive The variable cpqIdeLogicalDriveStatus indicates the curre...

Page 58: ...neFanStatus NT Event ID 1189 Hex 0x843504a5 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Temperature Status Change Log Message An enclosure attached to port 5 of storage system 4 has a new temperature status of 7 The enclosure model is 6 SNMP Trap cpqSsExBackplaneTempStatusChange 8023 in CPQSTSYS MIB Symptom Storage System Temperature Status Change The agent has detected a change...

Page 59: ...orting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqSsBackplaneIndex cpqSsBackplaneVendor cpqSsBackplaneModel cpqSsBackplaneSerialNumber cpqSsBackplaneFtpsStatus Supporting SNMP Trap Description Storage system power supply status changed to cpqSsBackplaneFtpsStatus NT Event ID 1191 Hex 0x843504a7 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library Status...

Page 60: ...rIndex cpqTapePhyDrvBusIndex cpqTapePhyDrvScsiIdIndex cpqTapePhyDrvLunIndex cpqTapePhyDrvName cpqTapePhyDrvFwRev cpqTapePhyDrvSerialNumber cpqTapePhyDrvStatus Supporting SNMP Trap Description Status is now cpqTapePhyDrvStatus NT Event ID 1193 Hex 0x843504a9 cpqstmsg dll Log Severity Warning 2 Event Title External Tape Drive Status Change Log Message The tape drive at location 4 has a new status of...

Page 61: ...pFlags cpqFcTapeDriveCntlrIndex cpqFcTapeDriveScsiBus cpqFcTapeDriveScsiTarget cpqFcTapeDriveScsiLun cpqFcTapeDriveModel cpqFcTapeDriveFWRev cpqFcTapeDriveSerialNumber cpqFcTapeDriveLocation Supporting SNMP Trap Description Cleaning is needed for tape drive NT Event ID 1195 Hex 0x843504ab cpqstmsg dll Log Severity Warning 2 Event Title External Tape Drive Replace Cleaning Tape Log Message The clea...

Page 62: ... is secondaryRunningAuto 8 or secondaryRunningUser 9 examine the primary server for failed components Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqSsChassisRsoStatus cpqSsChassisIndex Supporting SNMP Trap Description Storage system recovery server option status changed to cpqSsChassisRsoStatus NT Event ID 1197 Hex 0x843504ad cpqstmsg dll Log Severity Warnin...

Page 63: ...s indicates the current tape library door status User Action If the tape library door is open close the tape library door Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqFcTapeLibraryCntlrIndex cpqFcTapeLibraryScsiBus cpqFcTapeLibraryScsiTarget cpqFcTapeLibraryScsiLun cpqFcTapeLibraryModel cpqFcTapeLibraryFWRev cpqFcTapeLibrarySerialNumber cpqFcTapeLibraryLocation cpqFcTapeLibraryDoorStatus Su...

Page 64: ...of 2 SNMP Trap cpqDa6LogDrvStatusChange 3034 in CPQIDA MIB Symptom Logical Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array logical drive The variable cpqDaLogDrvStatus indicates the current logical drive status Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaCntlrHwLocation cpqDaLogDrvCntlrIndex cpqDaLogDrvIndex cpqDaLogDrvStatus Su...

Page 65: ...e This trap indicates that the agent has detected a change in the status of a drive array physical drive The variable cpaDaPhyDrvStatus indicates the current physical drive status User Action If the physical drive status is failed 3 or predictive Failure 4 replace the drive Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaCntlrHwLocation cpqDaPhyDrvCntlrIndex cpqDaPhyDrvIndex cpqDaPhyDrvBusNu...

Page 66: ...ning 2 Event Title Drive Array Accelerator Status Change Log Message The array accelerator board attached to the array controller in 4 has a new status of 2 SNMP Trap cpqDa6AccelStatusChange 3038 in CPQIDA MIB Symptom Accelerator Board Status Change This trap indicates that the agent has detected a change in the status of an array accelerator cache board The current status is represented by the va...

Page 67: ...CntlrIndex cpqDaAccelSerialNumber cpqDaAccelTotalMemory Supporting SNMP Trap Description Accelerator lost battery power Data Loss possible NT Event ID 1206 Hex 0x843504b6 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Accelerator Battery Failed Log Message The array accelerator board attached to the array controller in 4 is reporting a battery failure SNMP Trap cpqDa6AccelBatteryFaile...

Page 68: ...n cpqDaTapeLibraryModel cpqDaTapeLibraryFWRev cpqDaTapeLibrarySerialNumber cpqDaTapeLibraryStatus Supporting SNMP Trap Description Status is now cpqDaTapeLibraryStatus for the tape library NT Event ID 1208 Hex 0x843504b8 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Library Door Status Change Log Message The tape library in 4 SCSI bus 5 SCSI target 6 has a new door status of 7 S...

Page 69: ...e User Action If the tape is failed check the tape and all SCSI connections Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaCntlrHwLocation cpqDaTapeDrvCntlrIndex cpqDaTapeDrvBusIndex cpqDaTapeDrvScsiIdIndex cpqDaTapeDrvLunIndex cpqDaTapeDrvName cpqDaTapeDrvFwRev cpqDaTapeDrvSerialNumber cpqDaTapeDrvStatus Supporting SNMP Trap Description Status is now cpqDaTapeDrvStatus for a tape drive NT ...

Page 70: ...ed with a new cleaning tape Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqDaCntlrHwLocation cpqDaTapeDrvCntlrIndex cpqDaTapeDrvBusIndex cpqDaTapeDrvScsiIdIndex cpqDaTapeDrvLunIndex cpqDaTapeDrvName cpqDaTapeDrvFwRev cpqDaTapeDrvSerialNumber Supporting SNMP Trap Description Cleaning tape needs replacing NT Event ID 1212 Hex 0x843504bc cpqstmsg dll Log Severity Warning 2 Event Title Storage Sy...

Page 71: ... down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsBoxCntlrHwLocation cpqSsBoxCntlrIndex cpqSsBoxBusIndex cpqSsBoxVendor cpqSsBoxModel cpqSsBoxSerialNumber cpqSsBoxTempStatus Supporting SNMP Trap Description Storage System temperature status cha...

Page 72: ... Fibre Channel Host Controller Status Change This trap indicates that the agent has detected a change in the status of a Fibre Channel Host Controller The variable cpqFcaHostCntlrStatus indicates the current controller status User Action If the controller status is failed replace the controller Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqFcaHostCntlrHwLocation cpqFcaHostCntlrIndex cpqFcaHo...

Page 73: ... Trap Description Physical Drive Status is now cpqDaPhyDrvStatus NT Event ID 1217 Hex 0x843504c1 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Spare Drive Status Change Log Message The spare drive in 4 5 has a new status of 2 SNMP Trap cpqDa7SpareStatusChange 3047 in CPQIDA MIB Symptom Spare Drive Status Change This trap indicates that the agent has detected a change in the status of...

Page 74: ...tionString Supporting SNMP Trap Description Storage System fan status changed to cpqSsBoxFanStatus NT Event ID 1219 Hex 0x843504c3 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Temperature Status Change Log Message The 6 7 storage system connected to 5 of the controller in 4 has a new temperature status of 2 SNMP Trap cpqSs6TempStatusChange 8030 in CPQSTSYS MIB Symptom Storage Sys...

Page 75: ...ly status User Action If the power supply status is degraded restore power or replace the failed power supply Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSsBoxCntlrHwLocation cpqSsBoxCntlrIndex cpqSsBoxBusIndex cpqSsBoxVendor cpqSsBoxModel cpqSsBoxSerialNumber cpqSsBoxFltTolPwrSupplyStatus cpqSsBoxLocationString Supporting SNMP Trap Description Storage System power supply status changed to...

Page 76: ...able Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSasHbaHwLocation cpqSasLogDrvHbaIndex cpqSasLogDrvIndex cpqSasLogDrvStatus cpqSasLogDrvOsName Supporting SNMP Trap Description Status is now cpqSasLogDrvStatus Event identifier cpqstmsg dll 1280 Hex 0x84350500 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system...

Page 77: ... the agents to the latest version Event Identifiers 1343 4613 Event identifier cpqstmsg dll 1343 Hex 0x8435053f Service Event Log Severity Warning 2 Log Message Duplicate SCSI port found in slot 1 The current system ROM may not support this SCSI controller You may need to update your system ROM Event identifier cpqstmsg dll 1344 Hex 0x84350540 Service Event Log Severity Warning 2 Log Message A ver...

Page 78: ...was unable to forward an SNMP trap to the Remote Insight Board trap due to processing error The data contains the error code Event identifier cpqstmsg dll 1806 Hex 0x8435070e Service Event Log Severity Warning 2 Log Message The Storage Agent service is not running The SNMP Agent has determined that the Storage Agent service is not running Stop the SNMP service and restart the Storage Agents servic...

Page 79: ...sage The IDE Agent found an incorrect type for registry value 1 The data contains the type found Event identifier cpqstmsg dll 3590 Hex 0x84350e06 Service Event Log Severity Warning 2 Log Message The IDE Agent could not create an event The data contains the error code Event identifier cpqstmsg dll 3591 Hex 0x84350e07 Service Event Log Severity Warning 2 Log Message The IDE Agent could not open an ...

Page 80: ... Message The IDE Agent received an unknown action code from the service The data contains the action code Event identifier cpqstmsg dll 4097 Hex 0x84351001 Service Event Log Severity Warning 2 Log Message Could not read from the registry subkey This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4098 Hex...

Page 81: ...egistry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4611 Hex 0x84351203 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4612 Hex 0x84351204 Service Event Log S...

Page 82: ...2 Log Message The Server Agents service could not set the service status with the Service Control Manager The data contains the error code Event identifier cpqsvmsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The Server Agents service could not create an event object The data contains the error code Event identifier cpqsvmsg dll 261 Hex 0x84350105 Service Event Log Seve...

Page 83: ...alid state for agent 1 The data contains the state Event identifier cpqsvmsg dll 269 Hex 0x8435010d Service Event Log Severity Warning 2 Log Message The Server Agents service could not stop agent 1 The data contains the error code Event identifier cpqsvmsg dll 270 Hex 0x8435010e Service Event Log Severity Warning 2 Log Message The Server Agents service could not terminate agent 1 The data contains...

Page 84: ... cpqsvmsg dll 770 Hex 0x84350302 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent detected an error while attempting to retrieve data from key 1 in the registry The data contains the error code Event identifier cpqsvmsg dll 771 Hex 0x84350303 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent was unable to log an event in the event log of the system ...

Page 85: ...TH MIB Symptom Advanced Memory Protection Online Spare Engaged The Advanced Memory Protection subsystem has detected a memory fault The Online Spare Memory has been activated User Action Schedule server down time to replace the faulty memory Supporting SNMP Trap Data sysName cpqHoTrapFlags Supporting SNMP Trap Description The Advanced Memory Protection subsystem has engaged the online spare memory...

Page 86: ... The XOR recovery engine has been activated Schedule server down time to replace the memory SNMP Trap cpqHeResilientMemXorMemoryEngaged 6053 in CPQHLTH MIB Symptom Advanced Memory Protection XOR Engine Memory Engaged The Advanced Memory Protection subsystem has detected a memory fault The XOR engine has been activated User Action Replace the faulty memory Supporting SNMP Trap Data sysName cpqHoTra...

Page 87: ... corrected but the memory module should be replaced Value 0 for CPU means memory is not processor based Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqHeResMem2BoardNum cpqHeResMem2CpuNum cpqHeResMem2RiserNum cpqHeResMem2ModuleNum cpqHeResMem2ModulePartNo cpqHeResMem2ModuleSize cpqSiServerSystemId Supporting SNMP Trap Description Correctable memory errors require a replacement of the memory m...

Page 88: ...sub system board cartridge or riser has been installed Value 0 for CPU means memory is not processor based User Action None SNMP Trap Data sysName cpqHoTrapFlags cpqHeResMem2BoardSlotNum cpqHeResMem2BoardCpuNum cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description Memory Board or Cartridge Inserted into Slot cpqHeResMem2BoardSlotNum Cpu cpqHeResMem2BoardCpuNum Riser cpqHeResMem2BoardRiserNum ...

Page 89: ...tion subsystem has engaged the LockStep memory NT Event ID 1072 Hex 0x84350430 cpqsvmsg dll Log Severity Warning 2 Log Message The frequency of memory errors is high enough such that tracking of correctable memory errors has been temporarily disabled SNMP Trap cpqHe3CorrectableMemoryLogDisabled 6016 in CPQHLTH MIB Symptom Correctable memory error tracking disabled The frequency of errors is so hig...

Page 90: ...Log Severity Information 1 Log Message The Thermal Temperature Condition has been set to OK The server s temperature has returned to its normal operating range SNMP Trap cpqHe3ThermalTempOk 6019 in CPQHLTH MIB Symptom The temperature status has been set to OK The server s temperature has returned to the normal operating range Supporting SNMP Trap Data sysName cpqHoTrapFlags Supporting SNMP Trap De...

Page 91: ...em fan has resumed normal operation SNMP Trap cpqHe3ThermalSystemFanOk 6022 in CPQHLTH MIB Symptom The system fan status has been set to OK Any previously non operational system fans have returned to normal operation Supporting SNMP Trap Data sysName cpqHoTrapFlags Supporting SNMP Trap Description System fan has returned to normal operation NT Event ID 1088 Hex 0xc4350440 cpqsvmsg dll Log Severity...

Page 92: ...Trap Description Server is operational again after ASR shutdown NT Event ID 1091 Hex 0x44350443 cpqsvmsg dll Log Severity Information 1 Log Message The server is operational again The server has previously been shut down due to a thermal anomaly and has just become operational again SNMP Trap cpqHe3ThermalConfirmation 6026 in CPQHLTH MIB Symptom The server is operational again The server has previ...

Page 93: ...login attempts More than 4 login attempts detected SNMP Trap cpqSm2UnauthorizedLoginAttempts 9003 in CPQSM2 MIB Symptom Remote Insight Integrated Lights Out Unauthorized Login Attempts The Remote Insight Integrated Lights Out firmware has detected unauthorized login attempts Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSm2CntlrBadLoginAttemptsThresh Supporting SNMP Trap Description More tha...

Page 94: ...sight Integrated Lights Out interface The firmware is not responding Supporting SNMP Trap Data sysName cpqHoTrapFlags Supporting SNMP Trap Description Server sysName Remote Insight Integrated Lights Out interface error NT Event ID 1112 Hex 0x84350458 cpqsvmsg dll Log Severity Warning 2 Log Message The Remote Insight Board has detected that the battery is disconnected SNMP Trap cpqSm2BatteryDisconn...

Page 95: ...e last system start up Be sure the system cover is installed properly This situation may result in improper cooling of the system due to air flow changes caused by the missing cover SNMP Trap cpqSiHoodRemoved 2001 in CPQSINFO MIB Symptom The access panel is removed The access panel status has been set to removed The access panel is not installed properly This situation may result in improper cooli...

Page 96: ...ion has been set back to the OK state for the specified chassis and bay location Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqHeFltTolPowerSupplyChassis cpqHeFltTolPowerSupplyBay cpqHeFltTolPowerSupplyStatus cpqHeFltTolPowerSupplyModel cpqHeFltTolPowerSupplySerialNumber cpqHeFltTolPowerSupplyAutoRev cpqHeFltTolPowerSupplyFirmwareRev cpqHeFltTolPowerSupplySparePartNum cpqSiServerSystemId Sup...

Page 97: ...erSupplyAutoRev cpqHeFltTolPowerSupplyFirmwareRev cpqHeFltTolPowerSupplySparePartNum cpqSiServerSystemId Supporting SNMP Trap Description The Power Supply is Degraded on Chassis cpqHeFltTolPowerSupplyChassis Bay cpqHeFltTolPowerSupplyBay Status cpqHeFltTolPowerSupplyStatus Model cpqHeFltTolPowerSupplyModel Serial Num cpqHeFltTolPowerSupplySerialNumber Firmware cpqHeFltTolPowerSupplyFirmwareRev NT ...

Page 98: ...ng SNMP Trap Data sysName cpqHoTrapFlags cpqHeFltTolPowerSupplyChassis Supporting SNMP Trap Description The Power Supplies are no longer redundant on Chassis cpqHeFltTolPowerSupplyChassis NT Event ID 1127 Hex 0x44350467 cpqsvmsg dll Log Severity Information 1 Log Message Fault Tolerant Power Supply Inserted A hot plug fault tolerant power supply has been inserted into the system SNMP Trap cpqHe3Fl...

Page 99: ...Chassis cpqHeFltTolFanIndex Supporting SNMP Trap Description The Fan Degraded on Chassis cpqHeFltTolFanChassis Fan cpqHeFltTolFanIndex NT Event ID 1130 Hex 0xc435046a cpqsvmsg dll Log Severity Error 3 Log Message The Fan Sub system is in a failed state Replace the fan SNMP Trap cpqHe3FltTolFanFailed 6036 in CPQHLTH MIB Symptom The Fault Tolerant Fan condition has been set to failed for the specifi...

Page 100: ...ID 1133 Hex 0x8435046d cpqsvmsg dll Log Severity Warning 2 Log Message Fan Removed A hot plug fan has been removed from the system SNMP Trap cpqHe3FltTolFanRemoved 6039 in CPQHLTH MIB Symptom A Fault Tolerant Fan has been removed from the specified chassis and fan location Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqHeFltTolFanChassis cpqHeFltTolFanIndex Supporting SNMP Trap Description Th...

Page 101: ...emperatureChassis cpqHeTemperatureLocale Supporting SNMP Trap Description Temperature out of range on Chassis cpqHeTemperatureChassis Location cpqHeTemperatureLocale Shutdown may occur NT Event ID 1136 Hex 0x44350470 cpqsvmsg dll Log Severity Information 1 Log Message A Temperature Sensor Condition has been set to OK The system s temperature has returned to the normal operating range SNMP Trap cpq...

Page 102: ...ting SNMP Trap Data sysName cpqHoTrapFlags cpqHePwrConvChassis cpqHePwrConvSlot cpqHePwrConvSocket Supporting SNMP Trap Description The Power Converter Failed on Chassis cpqHePwrConvChassis Slot cpqHePwrConvSlot Socket cpqHePwrConvSocket NT Event ID 1139 Hex 0x84350473 cpqsvmsg dll Log Severity Warning 2 Log Message The DC DC power converter is in a failed state Replace System Information Agent He...

Page 103: ...ymptom Hot Plug Slot Board Inserted A Hot Plug Slot Board has been inserted into the specified chassis and slot User Action None Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqSiHotPlugSlotChassis cpqSiHotPlugSlotIndex Supporting SNMP Trap Description Hot Plug Slot Board Inserted into Chassis cpqSiHotPlugSlotChassis Slot cpqSiHotPlugSlotIndex NT Event ID 1142 Hex 0xc4350476 cpqsvmsg dll Log S...

Page 104: ...MP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackSerialNum cpqRackTrapSequenceNum Supporting SNMP Trap Description The rack name has changed to cpqRackName NT Event ID 1144 Hex 0x44350478 cpqsvmsg dll Log Severity Information 1 Log Message Rack Enclosure Name Changed SNMP Trap cpqRackEnclosureNameChanged 22002 in CPQRACK MIB Symptom The enclosure name has changed This trap indicat...

Page 105: ...cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName has been removed from rack cpqRackName NT Event ID 1146 Hex 0x4435047a cpqsvmsg dll Log Severity Information 1 Event Title Enclosure Inserted Log Message This trap indicates that an enclosure has been inserted into the...

Page 106: ...onEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureTempLocation cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName temperature sensor in rack cpqRackName has been set to failed NT Event ID 1148 Hex 0x8435047c cpqsvmsg dll Log Severity Warning 2 Event Title Rack Enclosure Overheatin...

Page 107: ...kUid cpqRackCommonEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureTempLocation cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName temperature sensor in rack cpqRackName has been set to ok NT Event ID 1150 Hex 0xc435047e cpqsvmsg dll Log Severity Error 3 Event Title Rack Enclosure ...

Page 108: ...n has failed but that other fans in the redundant fan group are still operating This may result in the enclosure overheating User Action Replace the fan as soon as possible Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackCommonEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureFanLocation cpqRackCommonEnclosureFanSparePartNumber cpqRackCommonEnclosur...

Page 109: ...K MIB Symptom The enclosure fan has been removed User Action None Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackCommonEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureFanLocation cpqRackCommonEnclosureFanSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName fan in rack cpqR...

Page 110: ... power supply as soon as possible Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackPowerSupplyEnclosureName cpqRackPowerSupplySerialNum cpqRackPowerSupplyPosition cpqRackPowerSupplyFWRev cpqRackPowerSupplySparePartNumber cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power supply cpqRackPowerSupplyPosition in...

Page 111: ...ly has returned to normal operation SNMP Trap cpqRackPowerSupplyOk 22015 in CPQRACK MIB Symptom The power supply status has been set to OK This trap indicates that a power supply has returned to normal operation User Action None Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackPowerSupplyEnclosureName cpqRackPowerSupplySerialNum cpqRackPowerSupplyPosition cpqRackPower...

Page 112: ...vent ID 1159 Hex 0x44350487 cpqsvmsg dll Log Severity Information 1 Event Title Rack Power Supply Inserted Log Message The power supply has been inserted SNMP Trap cpqRackPowerSupplyInserted 22017 in CPQRACK MIB Symptom The power supply has been inserted User Action None Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackPowerSupplyEnclosureName cpqRackPowerSupplySerial...

Page 113: ...everity Warning 2 Event Title Rack Power Subsystem Input Voltage Problem Log Message The rack power supply detected an input line voltage problem SNMP Trap cpqRackPowerSubsystemLineVoltageProblem 22019 in CPQRACK MIB Symptom The rack power supply detected an input line voltage problem User Action Check the power input for the power supply or replace any failed power supplies as soon as possible Su...

Page 114: ...ack cpqRackName is in an overload condition NT Event ID 1163 Hex 0xc435048b cpqsvmsg dll Log Severity Error 3 Event Title Server Power Shedding Shutdown Log Message Server shutdown due to power shedding SNMP Trap cpqRackPowerShedAutoShutdown 22021 in CPQRACK MIB Symptom Server shutdown due to power shedding The server blade was shut down due to a lack of power User Action Check power connections o...

Page 115: ...rver power on prevented to preserve redundancy in blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1165 Hex 0xc435048d cpqsvmsg dll Log Severity Error 3 Event Title Not Enough Power To Power On Log Message Inadequate power to power on SNMP Trap cpqRackServerPowerOnFailedNotEnoughPower 22023 in CPQRACK MIB Symptom Inadequate power to powe...

Page 116: ...eSerialNum cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Inadequate power to power on blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1167 Hex 0xc435048f cpqsvmsg dll Log Severity Error 3 Event Title Inadequate Power To Power On Log Message There is not enough power to power on the server blade The power enclosu...

Page 117: ...cpqRackUid cpqRackServerBladeEnclosureName cpqRackServerBladePosition cpqRackServerBladeSparePartNumber cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Server power on via manual override on blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1169 Hex 0x84350491 cpqsvmsg dll Log Severit...

Page 118: ...cpqRackServerBladeEnclosureName cpqRackServerBladeName cpqRackServerBladePosition cpqRackServerBladeSparePartNumber cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Server blade cpqRackServerBladeName removed from position cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1171 Hex 0x44350493...

Page 119: ...lies Replace any failed or degraded power supplies Add additional power supplies if needed Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackCommonEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem not load balanced in enclosure cpqRackCommonEnclosure...

Page 120: ...ies Replace any failed or degraded power supplies Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackCommonEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem AC facility input power exceeded in enclosure cpqRackCommonEnclosureName in rack cpqRackName N...

Page 121: ...ckCommonEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem load balancing wire missing for enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1177 Hex 0x84350499 cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem Too Many Power Enclosures Log Messag...

Page 122: ... been improperly configured in enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1179 Hex 0x8435049B cpqsvmsg dll Log Severity Warning 2 Log Message The Management Processor is in reset state The data contains the error code SNMP Trap cpqHeManagementProcInReset 6061 in CPQHLTH MIB Symptom The Management processor is currently in reset The management processor is currently in the...

Page 123: ...upporting SNMP Trap Data sysName cpqHoTrapFlags Supporting SNMP Trap Description The Management processor failed reset NT Event ID 1182 Hex 0x4435049EL Log Severity Informational Log Message USB storage device 5 attached The data contains the error code SNMP Trap 1008 in CPQSTDEQ MIB Symptom The USB key is attached to the server User Action None required Supporting SNMP Trap Data sysName cpqHoTrap...

Page 124: ...rver Agents the software support drivers or running the Emergency Repair procedure may correct this error Event identifier cpqsvmsg dll 1544 Hex 0x84350608 Service Event Log Severity Warning 2 Log Message Unable to read from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqsvmsg dll 1574 Hex 0xc435...

Page 125: ...to deliver a trap This can be caused by a failure in the Remote Access Service or by a missing or invalid configuration Use the Management Agent control panel to verify the Asynchronous Management configuration settings Use the Network control panel to verify the Remote Access configuration If this error persists reinstalling the Server Agents or the Remote Access Service may correct this error Fo...

Page 126: ...ht Board device driver CPQSM2 SYS to be installed Install the driver from the latest Software Support for Windows If you do not have a Remote Insight Board in this system disable the Remote Insight Agent via the Management Agents Control Panel Event identifier cpqsvmsg dll 3351 Hex 0x84350d17 Service Event Log Severity Warning 2 Log Message The shared memory interface has been reset Event identifi...

Page 127: ...ntains the error code Event identifier cpqsvmsg dll 5640 Hex 0x84351608 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not create its main thread of execution The data contains the error code Event identifier cpqsvmsg dll 5641 Hex 0x84351609 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent main thread did not terminate prope...

Page 128: ... MIB Agent could not set the variable because it is unsupported The data contains the error code Event identifier cpqsvmsg dll 5683 Hex 0x84351633 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not set the variable because the value is invalid or out of range The data contains the error code Event identifier cpqsvmsg dll 5684 Hex 0x84351634 Service Event Lo...

Page 129: ...us with the Service Control Manager The data contain the error code Event identifier cpqnimsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not start the Service Control Dispatcher The data contain the error code Event identifier cpqnimsg dll 261 Hex 0x84350105 Service Event Log Severity Warning 2 Log Message Unable to read from the registry...

Page 130: ...5010c Service Event Log Severity Warning 2 Log Message Unable to enumerate 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 269 Hex 0xc435010d Service Event Log Severity Error 3 Log Message The NIC Management Agent encountered a fatal error The service is terminating The data conta...

Page 131: ...5 Service Event Log Severity Information 1 Log Message The NIC Management Agent version 1 has started Event identifier cpqnimsg dll 279 Hex 0x84350117 Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not set an event The data contain the error code Event identifier cpqnimsg dll 280 Hex 0x84350118 Service Event Log Severity Warning 2 Log Message The NIC Management Age...

Page 132: ...pqnimsg dll 293 Hex 0x84350125 Service Event Log Severity Warning 2 Log Message The NIC Agent service could not terminate agent 1 The data contain the error code Event identifier cpqnimsg dll 294 Hex 0x84350126 Service Event Log Severity Warning 2 Log Message The NIC Agent service could not unload the module 1 The data contain the error code Event identifier cpqnimsg dll 296 Hex 0xc4350128 Service...

Page 133: ...ity Warning 2 Log Message The NIC SNMP Management Agent s trap thread has encountered an error while waiting for event notification from event log Event identifier cpqnimsg dll 1027 Hex 0x84350403 Service Event Log Severity Warning 2 Log Message The SNMP Agent is older than other components The SNMP Agent is older than the other components of the Insight Agents Reinstall the entire Insight Agents ...

Page 134: ...ifier cpqnimsg dll 1035 Hex 0xc435040b Service Event Log Severity Error 3 Log Message Unable to load a required library This error can be caused by a corrupt or missing file Reinstalling the Insight Agents or running the Emergency Repair procedure may correct this error Event identifier cpqnimsg dll 1036 Hex 0x8435040c Service Event Log Severity Warning 2 Log Message The NIC SNMP Management Agent ...

Page 135: ...apter group returns to the OK condition This trap is not sent when a logical adapter group has connectivity restored from a Failed condition The cpqNicConnectivityRestored trap is sent instead This can be caused by replacing a faulty cable or by connecting a cable that was disconnected User Action None required Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqNicIfPhysAdapterSlot cpqNicIfPhysAd...

Page 136: ...qNicIfPhysAdapterSlot cpqNicIfPhysAdapterPort cpqSiServerSystemId cpqNicIfPhysAdapterStatus cpqSePciSlotBoardName cpqNicIfPhysAdapterPartNumber ipAdEntAddr cpqNicIfLogMapIPV6Address Supporting SNMP Trap Description Connectivity is restored for adapter in slot cpqNicIfPhysAdapterSlot port cpqNicIfPhysAdapterPort NT Event ID 1291 Hex 0xc435050B cpqnimsg dll Log Severity Error 3 Log Message Connectiv...

Page 137: ...OK condition This trap is not sent when a logical adapter group has connectivity restored from a Failed condition The cpqNicConnectivityRestored trap is sent instead This can be caused by replacing of a faulty cable or connecting a cable that was disconnected User Action None required Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqNicIfPhysAdapterSlot cpqNicIfPhysAdapterPort cpqSiServerSystem...

Page 138: ... this condition User Action Check the cables to the adapter and the Hub or Switch If no cable problems are found the adapter Hub or Switch may need replacement Supporting SNMP Trap Data sysName cpqHoTrapFlags cpqNicIfPhysAdapterSlot cpqNicIfPhysAdapterPort cpqSiServerSystemId cpqNicIfPhysAdapterStatus cpqSePciSlotBoardName cpqNicIfPhysAdapterPartNumber ipAdEntAddr cpqNicIfLogMapIPV6Address cpqNicI...

Reviews: