background image

 

 

HP 10000 G2 Series Rack 

User Guide 

 

 

Part Number 391312-006 

August 2010 (Sixth Edition) 

Summary of Contents for 10622 G2

Page 1: ...HP 10000 G2 Series Rack User Guide Part Number 391312 006 August 2010 Sixth Edition ...

Page 2: ...ng such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intended audience This document is for the person who installs racks and rack products This procedure is performed only by trained personnel HP assumes you are qualified in performing installations and trained...

Page 3: ...k stabilizer option kit 16 Rack baying option kit 17 Rack tie down option kit 17 Installing components 19 Installing components 19 Installing the cage nuts 19 Installing the hook and loop components 21 Installing the cable management brackets 22 Rack options 23 Ordering rack options 23 Specifications 25 HP G2 rack specifications 25 HP 10622 G2 Rack specifications 25 HP 10636 G2 Rack specifications...

Page 4: ...Grounding methods to prevent electrostatic discharge 27 Technical support 28 Before you contact HP 28 HP contact information 28 Acronyms and abbreviations 29 Index 30 ...

Page 5: ...ance The HP eCo Enterprise Configurator now provides factory default racking for HP hardware This approach is aligned with the strategic direction to meet the needs and expectations of valued customers If you require a custom rack configuration contact the HP Customer Business Center or an authorized partner for assistance Optimum environment Specific requirements for space power temperature and a...

Page 6: ...iguration of equipment in the rack Check the TMRA for each piece of equipment before installation CAUTION To reduce the risk of damage to the equipment when installing third party options Do not permit optional equipment to impede airflow around the component or to increase the internal rack temperature beyond the maximum allowable limits Do not exceed the manufacturer s TMRA Airflow requirements ...

Page 7: ...tions for Server and Network Products on the HP website http www hp com search for Safety and Comfort Guide Additional rack considerations Consider the following specifications and components with regard to your specific rack configuration Power If a UPS is installed do not exceed its output rating Be sure to review the installation instructions provided with each component for important cautions ...

Page 8: ...ed with deployments of stand alone racks Rack rows with four or more bayed racks without a single rack mountable component exceeding 99 8 kg 220 lb do not need a stabilizer kit installed o The heavy duty 600 mm 23 6 in or 800 mm 31 5 in front foot is required when a single rack mountable component weighing 99 8 kg 220 lb or more is installed in a stand alone rack or in a rack belonging to a rack r...

Page 9: ...e general guidelines For detailed instructions on installing specific component or third party hardware see the user documentation that shipped with that component Before installing components into the rack see the Electrostatic Discharge on page 27 section Use the configuration prepared by the eCo Enterprise Configurator as a guideline for installation components Load the heavier components first...

Page 10: ... hardware pieces You will typically have extra fasteners after completing your component installation IMPORTANT Retain the extra fasteners for future use Hardware kit contents If any of the following items are missing or damaged contact your HP authorized reseller 1 M6 screws 50 2 Cage nut insertion tool 1 3 M5 5 x 10 self tapping screws 6 4 M6 cage nuts 50 5 T 25 Torx bit 1 6 Cable management bra...

Page 11: ...iver T 25 Torx driver T 25 bit is included with your hardware kit T 30 Torx driver Adjustable wrench Cage nut insertion tool included with your hardware kit For comfort and efficiency while setting up your rack use power tools where applicable Removing the rack doors To provide access to all sides of the rack while you are installing the various components first remove the rack doors If your rack ...

Page 12: ...r component installation 12 2 Lift the top hinge pin up and tilt the door away from the rack 3 Lift the door up to remove it from the bottom hinge Store the door in an upright position taking care to protect it from damage ...

Page 13: ...y pulling up on the top hinge pin and pulling down on the bottom hinge pin for each door 3 Lift the rear doors off of the hinge brackets and remove them from the rack 2 Store the doors in an upright position taking care to protect them from damage Removing the side panels NOTE The side panels come preinstalled on all HP 10622 G2 Racks ...

Page 14: ...Preparing the rack for component installation 14 1 Unlock the middle side panel locks and remove the side panel from the rack ...

Page 15: ...nt when equipment is routinely installed removed or accessed within the rack Stabilization can be achieved through the use of an HP Rack Stabilizer Option Kit HP Rack Baying Option Kit or HP Rack Tie Down Option Kit Observe the following tips when using multiple rack configurations A stabilizer kit is required or recommended depending on your rack configuration The side feet are required for stand...

Page 16: ...Rack stabilizer option kit The HP Rack Stabilizer Option Kit provides stability and support and prevents possible tipping when equipment is installed removed or accessed within the rack There are four stabilizer kit options Standard 600 mm 23 6 in or 800 mm 31 5 in front foot Required if you have a stand alone rack NOTE The standard 600 mm 23 6 in front foot ships with all HP 10622 G2 Racks ...

Page 17: ...zer Option Kit Installation Instructions Rack baying option kit The 10000 and 10000 G2 series rack can be bayed together by installing the HP Rack Baying Option Kit as long as they are the same series height and depth For example an HP 10636 Series Rack and an HP 10636 G2 Series Rack can be bayed together This configuration helps decrease space needs and increase stability For more information see...

Page 18: ... the tie downs Have your building structural engineer drill the holes Then secure the rack to the floor by inserting a bolt with a washer into each hole A separate tie down kit is used exclusively for the 1200 mm Full Frame Rack The following figure illustrates the 1200 mm Full Frame Rack Tie down Kit For more information see the HP 10000 G2 Series Rack Options Installation Guide ...

Page 19: ...d install the rails into the rack 3 Prepare and install the component into the rack and secure it 4 Attach the cable management arm to the rack and then to the component 5 Attach any cables and power cords being sure that you adhere to all cautions and warnings contained in the individual component installation instructions 6 Remove the cable access panel and route the cables Installing the cage n...

Page 20: ...Installing components 20 3 Use the insertion tool to pull the cage nut through the hole until the top lip snaps into position ...

Page 21: ...Installing components 21 Installing the hook and loop components Route and secure your cables with the hook and loop cabling strap clips ...

Page 22: ...ent brackets 1 Position the cable management bracket so that one side is attached to the inside of the rack frame 2 Slide the cable management bracket into place 1 3 Secure the cable management bracket to the rack frame and extension kit using one screw 2 Installation is complete ...

Page 23: ...the rear of your rack Ground bonding rack option kit Reduces the level of electromagnetic emissions outside of the rack Ballast rack option kit Provides rack stability when heavy equipment is installed removed or accessed within the rack Tie down rack option kit Enables you to secure your rack to the floor Baying rack option kit Joins multiple racks of the same series height and depth Fan 110V 220...

Page 24: ...lds and conceals a keyboard 100 kilo sliding shelf rack option kit Allows easy access to various rack components TFT7600RKM Rack mountable 1U keyboard and flat panel monitor on a drawer with room in the rear to add a switchbox TFT7210R flat panel monitor rackmount Rack mountable 1U flat panel monitor Depth adjustable fixed rail kit Provides rails that can be adjusted to various depths Shock pallet...

Page 25: ...ht Width Depth Dynamic load gross Static load 36U 600 mm 23 6 in 1 000 mm 39 4 in 689 5 kg 1 520 lb 907 2 kg 2 000 lb HP 10642 G2 Rack specifications U height Width Depth Dynamic load gross Static load 42U 600 mm 23 8 in 1 000 mm 39 4 in 907 2 kg 2 000 lb 1 360 8 kg 3 000 lb HP 10647 G2 Rack specifications U height Width Depth Dynamic load gross Static load 47U 600 mm 23 8 in 1 000 mm 39 4 in Not ...

Page 26: ...ll Frame Rack For more information see the HP 10000 G2 Series Rack Options Installation Guide HP 10842 G2 Rack specifications U height Width Depth Dynamic load gross Static load 42U 800 mm 31 5 in 1 000 mm 39 4 in 453 6 kg 1 000 lb 907 2 kg 2 000 lb HP 10642 Extended Depth Rack specifications U height Width Depth Dynamic load gross Static load 42U 600 mm 23 8 in 1 200 mm 47 2 in 907 2 kg 2 000 lb ...

Page 27: ...tic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance ...

Page 28: ...rldwide in English webpage http welcome hp com country us en wwcontact html For HP technical support In the United States for contact options see the Contact HP United States webpage http welcome hp com country us en contact_us html To contact HP by phone o Call 1 800 HP INVENT 1 800 474 6836 This service is available 24 hours a day 7 days a week For continuous quality improvement calls may be rec...

Page 29: ...ms and abbreviations CPU central processing unit CRT cathode ray tube KVM keyboard video and mouse PDU power distribution unit RKM rackmount keyboard monitor TMRA recommended ambient operating temperature UPS uninterruptible power system ...

Page 30: ...HP Rack Baying Option Kit 17 23 HP Rack Stabilizer Option Kit 16 23 HP Rack Tie Down Option Kit 17 23 I installing cable management brackets 22 installing cage nuts 19 installing components 19 K kit contents 10 O optimum environment 5 P populating your new rack 6 power requirements 6 preparing the rack for component installation 10 R rack baying option kit 17 23 rack configuration software 5 rack ...

Reviews: