background image

 

 

 

 

BioHarness 3 

 

 

QUICK REFERENCE 

 

 

By Honeywell 

IMPORTANT! 

Follow all instructions here before operating the BioHarness 3. Make sure your strap is 

the correct size before using it (available in two sizes, Small XS-M or Large M-XL). For more details, 
refer to the BioHarness 3, RAELink3 (or RAELink3 Z1, which has the same functions), and ProRAE 
Guardian User’s Guides or Quick References. 

 

The BioHarness 3 measures the following parameters: 

 

Sensor 

Unit 

Range 

Definition 

Breath Rate 

Bth/m (breaths per minute) 

0 to 120 

 

Heart Rate  

Bts/m (beats per minute) 

0 to 240 

 

Activity 

VMU (Vector Magnitude 
Units) 

±16 

<0.2 = Low Activity 
<0.8 = Walking/Jogging 
>0.8 = Running 

Posture 

Degrees 

0 to 180 

0 = Vertical 
90 = Horizontal 
180 = Inverted 

Temperature 

Degrees F or C 

50° to 140° F 
10° to 60° C 

 

 

 

Operation 

1.

 

Moisten the gray sensor pads on the back of the strap with water. 

 

 

 

2.

 

Snap the BioHarness Echo Module onto the BioHarness 3 by clicking the bottom in first and then the top. 

     

   

 

 

3.

 

Power on the BioHarness Echo Module by pressing the button in the center until all four LEDs flash. 

 

  

 

4.

 

Link the BioHarness Echo Module to the RAELink3. 

Note: 

It links automatically after the initial Bluetooth pairing. 

 

5.

 

Attach the shoulder strap with Velcro in the back and fit the clasp to the loop in the front, and 
then do the same with the clasp and loop in the front. 

 

           

Note: 

BioHarness Echo Module should be under the left armpit when properly positioned. 

Summary of Contents for RAE Systems BioHarness 3

Page 1: ...w Activity 0 8 Walking Jogging 0 8 Running Posture Degrees 0 to 180 0 Vertical 90 Horizontal 180 Inverted Temperature Degrees F or C 50 to 140 F 10 to 60 C Operation 1 Moisten the gray sensor pads on the back of the strap with water 2 Snap the BioHarness Echo Module onto the BioHarness 3 by clicking the bottomin first andthen the top 3 Power on the BioHarness Echo Module by pressing the button in ...

Page 2: ...is typically reached in 1 hour While charging the BioHarness Echo Module s orange LED flashes When fully charged the orange LED glows continuously 3 Once it is charged remove the BioHarness Echo Module from the Charging Cradle Pairing The BioHarness Echo Module And The RAELink3 Via Bluetooth After an initial pairing of the BioHarness Echo Module with the RAELink3 the two will automatically find ea...

Page 3: ...eless units within the ProRAE Guardian software If the Unit ID has not been set to a unique identification number you must set it 1 Enter Programming Mode on the RAELink3 by holding the N and MODE keys together 2 Press N until you can set the UNIT ID 3 Select a number between 01 and 64 4 Press and hold MODE for two seconds and save it Defining Alarm Levels Important Alarm limits should only be set...

Page 4: ...lect Properties 5 Choose the saved alarm template from the drop down menu and then click Apply 6 To remove alarm levels from a BioHarness 3 choose Remove Binding and then click Apply BioHarness 3 Strap Care The strap can be hand washed or machine laundered following these steps 1 Detach the BioHarness Echo Module 2 Hand wash using a mild soap or detergent or machine wash Cool temperature 40 C 104 ...

Page 5: ...device is not being worn Flash Heart rate locked Solid Error Green Solid Logging error Flash Logging Off Not logging LED State In Cradle Orange Off No power or not fully in cradle Solid Charged Flash Charging Blue Off Should be off at all times Red Should be off at all times Green Solid Logging error Off No logs finished downloading Flash Downloading RAELink3 Remote not communicating with ProRAE G...

Reviews: