MasterLogic-200 

High Speed Counter 

 

2MLF-HO2A 

2MLF-HD2A 

 

 

 

 

 

 

 

 

 

 

 
 

 

10310000614    Printed in Korea 

 
 
 
 
 
 
 

 

 

For more information on MasterLogic PLCs , contact your nearest Honeywell office 

 

 

Australia 

Honeywell Ltd. 
Phone : (61) 2-9353-4500 
Fax : (61) 2-9353-7677 
 

China 

Honeywell (Tianjin) Ltd. – Beijing 
Phone: (86-10) 8458-3280 
Fax: (86-10) 8458-3102 
 
Honeywell (Tianjin) Ltd. – Shanghai 
Phone: (86-21) 6237-0237 
Fax : (86-21) 6237-3102 
 

Indonesia 

PT Honeywell Indonesia 
Phone : (62) 21-535-8833 
Fax : (62) 21-5367-1008 
 

India 

Honeywell Automation India Ltd. 
Phone: (91) 20-5603-9400 
Fax: (91) 20-5603-9800 

 

Japan 

Honeywell Inc. 
Phone: (81)3-5440-1395 
Fax: (81)3-5440-1368 
 

South Korea 

Honeywell Co., Ltd. 
Phone : (82) 2-799-6114 
Fax : (82) 2-792-9015 
 

Malaysia 

Honeywell Engineering Sdn Bhd. 
Phone: (603) 7958-4988 
Fax: (603) 7958-8922 
 

New Zealand 

Honeywell Ltd. 
Phone: (64-9) 623-5050 
Fax: (64-9) 623-5060 
 

Philippines 

Honeywell Systems Inc.   
Phone: (63-2) 633-2830 
Fax: (63-2) 638-4013 

 

Singapore 

Honeywell Pte Ltd. 
Phone: (65) 6355-2828 
Fax: (65) 6445-3033 
 

Thailand  

Honeywell Systems Ltd. 
Phone: (662) 693-3099 
Fax: (662) 693-3085 
 

Taiwan 

Honeywell Taiwan Ltd. 
Phone: (886) 2-2245-1000 
Fax: (886) 2-2245-3241 
 

For Countries (SE Asia) Listed 
below, call Honeywell Singapore 
Office  

Pakistan, Cambodia, Laos, 
Myanmar, Vietnam and East Timor 
 

For Countries Listed below,   
call Honeywell India Office 

Bangladesh, Nepal, and Sri Lanka 

 

 

 

 

 

Honeywell Co., Ltd.   

Honeywell Process Solutions 

17F, Kukje Center Building, 191 Hangangro-2ga,   

Yongsan-gu, Seoul 140-702, Korea 

Tel : 82-2-799-6114 / Fax : 82-2-792-9015 

Email : [email protected] 

 
10310000614

 

  Printed in Korea 

 

Safety Precautions 

 

Safety Precautions is for using the product safe and correct in order to prevent the accidents and 

danger, so always follow the instructions. 

 

The precautions explained here only apply to the 2MLF-HO2A and 2MLF-HD2A module. For safety 

precautions on the PLC system, refer to the MasterLogic-200 CPU User’s manual. 

 

The precautions are divided into 2 sections, ‘Warning’ and ‘Caution’. Each of the meanings is 

represented as follows.   

If violated instructions, it may cause death, fatal injury or considerable 

loss of property. 

If violated instructions, it may cause a slight injury or slight loss of 

products 

 

The symbols which are indicated in the PLC and User’s Manual mean as follows 

Gives warnings and cautions to prevent from risk of injury, fire, or malfunction. 

 

Gives warnings and cautions to prevent from risk of electrical shock. 

 

Store this datasheet in a safe place so that you can take out and read whenever necessary.   

Always forward it to the end user. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Precautions for use 

 

Do not install in any places other than PLC controlled place. 

 

Ensure that the FG terminal is grounded with class 3 grounding which is dedicated to the PLC. 

Otherwise, it may cause disorder or malfunction of PLC 

 

 

Connect expansion connector correctly when expansion modules are needed. 

 

Do not detach PCB from the case of the module and do not modify the module. 

 

Turn off the power when attaching or detaching module. 

 

Cellular phone or walkie-talkie should be farther than 30cm from the PLC 

 

Input signal and communication line should be farther than minimum 100mm from a high-tension 

line and a power line in order not to be affected by noise and magnetic field. 

 

 

 

Before handling the product 

Before using the product, read the datasheet and the User’s manual through to the end carefully in 

order to use the product efficiently. 

 

 

MasterLogic-200 User’s Manual

 

Name Code 

2MLK-CPUH/CPUS User’s manual 

10310000648

 

MasterLogic-200 Basic instruction manual

10310000649

 

MasterLogic-200 Software manual 

10310000650

 

2MLF-HO2A/HD2A User’s manual 

10310000618  

 

 

 

 

 

 

 

High speed counter module designed for MasterLogic-200 series is used to count high 

speed pulses from the encoder and there are two types of the pulse type 2MLF-HO2A 

and the line drive type 2MLF-HD2A. 

 

General specifications of MasterLogic-200 series are as specified below. 

 

No

Item 

Specifications 

Related 

specifications 

Operating 

temp. 

0

℃∼

+

55

 

 

Storage 

temp. 

-25

℃∼

+70

 

 

Operating 

humidity 

5

95%RH, no dew allowed 

 

Storage 

humidity 

5

95%RH, no dew allowed 

 

For discontinuous vibration 

 

Frequency Acceleration  Amplitude  Number 

10

f< 57

 -  0.075mm 

57

f

150

 9.8m/s2(1G) 

For continuous vibration 

Frequency Acceleration  Amplitude 

10

f< 57

 -  0.035mm 

Vibration 

proof 

57

f

150

 4.9m/s2(0.5G) 

Each 10 times in 

X,Y,Z directions 

IEC 61131-2 

6  Impact proof 

* Max. impact acceleration: 147

(15G) 

* Authorized time: 11

 

* Pulse wave : Sign half-wave pulse (Each 3 times in X,Y,Z    directions) 

IEC 61131-2 

Square wave 

impulse noise 

±1,500V - 

 

Static electric 

discharging 

Voltage : 4kV(contact discharging) 

IEC61131-2, 

IEC61000-4-2 

Radiation 

electromagnetic 

field noise 

27 ~ 500MHz, 10 V/m 

IEC61131-2, 

IEC61000-4-3 

Class Power 

module 

Digital/ 

Analog I/O 

communication interface   

Noise proof 

Fast Transient 

/ burst noise 

Voltage 2kV 

kV 

IEC61131-2, 

IEC61000-4-4 

Ambient 

conditions 

No corrosive gas or dust 

 

 

Operating 

height 

2,000m or less 

 

10 

Pollution 

level 

2 or less 

 

11  Cooling type 

Natural air cooling 

 

 
 
 
 
 
 

 
 
 

Performance

 

specifications of high speed counter module are as specified below. 

 

Specification 

Item 

2MLF-H02A 2MLF-HD2A 

Signal A-phase, 

b-phase 

Input type 

Voltage input 

(Open Collector) 

Differential input 

(Line Drive): 

Count 

Input signal 

Signal level 

DC 5/12/24V 

RS-422A Line Drive/ 

HTL LEVEL Line Drive 

Max.count speed 

200Kpps 

500kpps 

  (HTL input is 250kpps) 

Number of channels 

Count range 

Signed 32-bit (-2,147,483,648 ~ 2,147,483,647) 
Linear count (if 32-bit range exceeded, carry/borrow occurs) 

Count type 

(program setting) 

Ring count (repeated count within setting range) 
1-phase input 
2-phase input 

Input mode 

(program setting) 

CW/CCW input 

Signal type 

Voltage 
Increasing/decreasing operation setting by B-phase input 

1-phase input 

Increasing/decreasing operation setting by program 

2-phase input 

Automatic setting by difference in phase 
A-phase input: increasing operation 

Up/down 

Setting 

CW/CCW 

B-phase input: decreasing operation 

1-phaseinput 

1/2 multiplier   (program setting) 

2-phaseinput 

1/2/4 multiplier  (Program setting) 

Multiplier 

function 

CW/CCW 

1-multiplier 

Sign 

Preset command input, additional function command input 

Sign level 

DC 5V/12V/24V(select terminal)input type 

Control input 

Sign type 

Voltage 

Output points 

2-point/channel(for each channel): terminal output available 

Type 

Select single-compared(>, >=, =, =<, <) or section 

compared output (included or excluded) (program setting) 

External output 

Output type 

Open collector output(Sink) 

Input sign 

A-phase, B-phase, Preset command, additional function 

command 

Output sign 

OUT1, OUT2 

Function to 

display 

operation 

status 

Operation 

status 

Module Ready, A/B phase pulse input status 

Count enable 

To be set through program 

(count available only in enable status) 

Preset function 

To be set through terminal or program 

Additional functions 

(program setting) 

Count clear, count latch, 

Section count (time setting value: 1~60000ms) 

M

t  f i

t f

 

Terminal 40-pin 

connector 

I/O Occupied points 

Fixed point assignment: 64, Variable point assignment: 16 

Internal consumed current 

270 mA 

270 mA 

Weight (g) 

90g 

 

 

 

1. Introduction

 

2. General specifications

 

3. Performance specifications

Caution 

Warning 

 

 

 

Before wiring the PLC, ensure to check the rated voltage and 

terminal arrangement for the module before wiring work. 

Risk of electric shock, fire and malfunction 

 

Tighten the screw of terminal block with the specified torque range. 

Risk of fire and electric shock if the terminal screw looses. 

 

Use the PLC in an environment that meets the general 

specifications contained in this datasheet. 

Risk of electrical shock, fire, erroneous operation and deterioration of the PLC. 

 

Be sure that external load does not exceed the rating of output module. 

Risk of fire and erroneous operation. 

 

Do not use the PLC in the environment of direct vibration 

Risk of electrical shock, fire and erroneous operation. 

 

Do not disassemble, repair or modify the PLC. 

Risk of electrical shock, fire and erroneous operation. 

 

When disposing of PLC and battery, treat it as industrial waste. 

Risk of poisonous pollution or explosion. 

Caution 

PLC

Others 

< Best > 

PLC 

Others 

PLC

Others

< Good > 

< Bad > 

 

 

X

 

Do not contact the terminals while the power is applied.

 

Risk of electric shock and malfunction. 

X

 

Do not drop or insert any metallic object into the product.

 

Risk of fire, electric shock and malfunction. 

X

 

Do not charge, heat, short, solder and break up the battery.

 

Risk of injury and fire by explosion and ignition. 

Warning 

DATASHEET 