background image

Copyright © 2003 Honeywell Inc.  •  All Rights Reserved

EN2B-0214GE51 R0503

74-3672-1

XILON

HANDHELD TOOL

USER GUIDE

Summary of Contents for EXCEL5000 OPEN XILON

Page 1: ...Copyright 2003 Honeywell Inc All Rights Reserved EN2B 0214GE51 R0503 74 3672 1 XILON HANDHELD TOOL USER GUIDE ...

Page 2: ... LonPoint Neuron 3120 3150 the Echelon logo the LONMARK logo and the LonUsers logo are trademarks of Echelon Corporation registered in the United States and other countries LonLink LonResponse LonSupport and LonMaker are trademarks of Echelon Corporation All other brand and product names are trademarks or registered trademarks of their respective holders ...

Page 3: ... Overview of Honeywell Specific Functions 15 Using Your XILON 17 Initial Steps 17 Switching XILON On 17 Switching XILON Off 18 XILON Set Up 20 General Settings 21 Honeywell Functions 21 Service Pin 22 Search 22 Edit NID 23 I O Functions 23 I O Dialog Screen XL Smart I O s and Distributed I O s only 24 Parameter Dialog Screen Compact ACU Controllers only 25 All Automatic 29 Honeywell Properties C o...

Page 4: ...oes my XILON switch OFF automatically 36 Possible Cause Number One 36 Possible Cause Number Two 36 Possible Cause Number Three 37 Why can t I turn my XILON on 37 Possible Cause Number One 37 Possible Cause Number Two 37 Why does the battery icon display a T 37 Possible Cause 37 The display shows the no access screen even though the node is present 38 Possible Cause 38 Glossary 39 Index 42 ...

Page 5: ...by a single individual with no knowledge of LONWORKS and no experience with tools like LonMaker for Windows XILON was originally conceived as a powerful tool capable of performing a much wider range of complex tasks However the goal of this User Guide is to familiarize the reader only with XILON s basic operation and especially with those functions which have been designed specifically for checkin...

Page 6: ...ponding node is entered into XILON s database automatically and such functions as I O Functions and All Automatic can then be utilized as desired Honeywell I O Functions Pressing the ENTER key while the I O Functions item has the focus enables you to perform wiring checks on Distributed I O modules and or Excel Smart I O modules Power OFF There are two ways of switching OFF XILON From the toolbar ...

Page 7: ...edge of LONWORKS or LonMaker for Windows is necessary More convenient operation With XILON the work can be carried out by a single technician using a convenient handheld device which can be connected to input output modules located throughout the LONWORKS network Additional manual override functionality With XILON field devices can be manually overridden and tested Lower Know how Requirements Prev...

Page 8: ...held Tool for Wiring Checks already equipped with a battery pack consisting of five 1 2 V nickel metal hydride batteries one power supply unit and attached cable which can be inserted into the power supply jack on the top left hand side of the device and connected to a standard 100 240 Vac power supply socket one 1 5 meter long LONWORKS network cable with an attached RJ11 connector which can be in...

Page 9: ...g LONWORKS network cable and the attached RJ11 connector XILON to the LONWORKS network and if desired supplying it with power 12 24 Vdc or 24 Vac The socket hence consists of the following six pins 1 Pin 1 is for connection to LON network A the pink LONWORKS wire 2 Pin 2 is for connection to LON network B the gray LONWORKS wire 3 Pin 3 is not connected i e not used 4 Pin 4 is not connected i e not...

Page 10: ... by first pressing the SHIFT key The top two rows represent the first ten letters of the alphabet as well as ten special functions Power Supply Unit and Attached Cable The power supply unit and attached cable include a EURO plug permitting the cable to be plugged into any standard EURO power supply socket with a primary voltage of from 100 Vac to 240 Vac The power supply unit has a built in transf...

Page 11: ...more items symbol or in inverse font indicating that there are more items momentarily hidden from sight located below above and below or above the displayed item in a list If one of these more items symbols is displayed in front of a colon of a focused item these keys can be used to move to an item appearing in a list e g 0 1 3 6 or as the length of a domain Focused items in the tool bar menu In t...

Page 12: ...hot key initiates the Address table function F7 Pressing the F7 hot key initiates the NV table function F8 Pressing the F8 hot key initiates the NV monitors 1 function F9 Pressing the F9 hot key initiates the NV monitors 2 function F10 The F10 hot key is available in most menus The assigned function is either to go to the toolbar menu or to open the menu for device set up The actual function avail...

Page 13: ...he selected item Deleting all items Press SHIFT and to select all of the nodes in the LONWORKS network You can then press SHIFT and DEL to delete all of the items You will be asked to confirm this with ENTER Changing Values If a value see also section I O Functions on page 23 is selected press ENTER to change the value The status line will be converted into an input line The character in front of ...

Page 14: ...al to the displayed minimum value must be less than or equal to the displayed maximum A correct value can then be entered NOTE You can exit from the edit mode only if the value is valid or the ESC key is pressed XILON will round up values to the nearest valid grid value for the parameter ...

Page 15: ...to wait for a service pin message from a node Alternatively the F2 hot key can be pressed Once the Service Pin function has been successfully carried out i e XILON has received a service pin message from a node the corresponding node is entered into XILON s database automatically and such functions as I O Functions and All Automatic can then be utilized as desired Search or F3 Pressing the ENTER k...

Page 16: ... be calculated by XILON on the basis of the available values The temperatures can be displayed either in degrees Celsius or degrees Fahrenheit This can be set up in the Honeywell Properties dialog All Automatic The All Automatic function enables you to switch back and forth between the automatic and manual reset modes of Excel Smart I Os only Distributed I O modules do not support the automatic ma...

Page 17: ...up Menu Shown for approx 2 seconds Honeywell XILON V 1 00 00 GUI 2030 New ENTER Old ESC Shown for approx 2 seconds Fig 3 Welcome screens database is not empty SDH BIOS V 1 401 c SysMik 2001 Reboot Del Setup Menu Shown for approx 2 seconds Honeywell XILON V 1 00 00 GUI 2030 Shown for approx 2 seconds Fig 4 Welcome screens database is empty If the database is not empty the BIOS first calculates the ...

Page 18: ...lable with SHIFT function key Functions available with function key Service Pin Short info on selected symbol F1 Help F10 Device Status line with battery and shift Fig 5 Toolbar menu for database with no entries In the case of an empty database only those four functions which can be immediately executed namely F2 get node via Service Pin this is the recommended method for selecting a node F3 Searc...

Page 19: ...n in the following figure Power OFF Service Pin Setup General Setup Address SPA interface NID 0005127924300 SecCode Qwzu F1 Help F10 Menu Fig 7 Switching OFF from the toolbar menu After the ENTER key is pressed a CRC checksum will be calculated and XILON will then be switched OFF If you have switched XILON OFF using this procedure the CRC checksum will be used for the next restart to make sure tha...

Page 20: ...ly to the toolbar menu The device screen can be selected from the main tree view menu too Use ESC from lower levels to go up one level every time it is pressed The device screen provides the following items Power OFF Select this item and press ENTER to switch XILON OFF Service Pin XILON sends a service pin message if the ENTER key is pressed while this item is focused Setup General Select this ite...

Page 21: ... up XILON Auto OFF This command opens the input line You can then enter values between 0 function is switched OFF and 20 minutes If the idle time reaches the entered value XILON switches OFF automatically if XILON is in the battery mode NOTE The database will not be changed if XILON is switched OFF automatically The Auto OFF time starts after the expiration of the time given by the value for the s...

Page 22: ... corresponding node is entered into XILON s database automatically and such functions as I O Functions and All Automatic can then be utilized as desired Search The search node function can be used to select a node XILON can find all of the nodes of the domains to which it belongs Additionally it can also find nodes of all other domains if these nodes are able to respond to a Query ID message NOTE ...

Page 23: ...on Honeywell modules e g Distributed I O modules and or Excel Smart I O modules and the setting up of parameters monitoring of the status of procurement of diagnostic information on Compact ACU controllers It appears only if at least one entry is present in the database XILON currently supports the following nodes Honeywell Distributed I Os XFL521 and XFL521B XFL522A and XFL522B XFL523 and XFL523B...

Page 24: ...anging Fig 17 I O dialog for supported node node 2 of a total of 4 nodes The status line displays text which changes cyclically the entire cycle is about 18 seconds long Specifically it displays D followed by the device name i e order number then the standard text then V followed by the version number and N followed by NEC firmware version number and then the standard text again Explanation of sym...

Page 25: ...es can range from 99 9 to 999 9 The up and down arrows at the right hand side of the table body can be used to go the previous next page of the table NOTE The temperatures can be displayed either in degrees Celsius or degrees Fahrenheit This can be set up in the Honeywell Properties dialog see below To change a binary output value press ENTER thus toggling the value until changed as desired To cha...

Page 26: ... g ZAC800 651 50 then the standard text then V followed by the version number and N followed by NEC firmware version number and then the standard text again Explanation of symbols in table header The text PARAM STATUS in column 1 of the table header stands for Parameter Name or Status Information Identifier The symbol XX in column 2 stands for the value The text UNIT in column 3 stands for Enginee...

Page 27: ...f Level 2 bar or C LeadLag CO Lead lag change over time Dfr Enabl Defrost enabled Dfr Call Defrost calling time Dfr Dur Defrost endurance time Dfr Intrv Defrost time interval Dfr CStDel Compressor start delay after defrost end Dfr SDelay Separate or Simultaneous Defrost 0 means simultaneous defrost or 1 30 min is the time interval between the two compressors Dfr Start Defrost start temperature or ...

Page 28: ...cannot be changed The following status information may occur in the list S WallSp Temperature Setpoint Wall Module 12 30 C or INV S RmTmp Room temperature S EffSp Effective Setpoint S HC Cmd Heat Cool Command S EvapFan Actual state of evaporator fan 0 or 100 S LeadC Lead Compressor S CFan1 Actual state of condenser fan 1 0 100 S CFan2 Actual state of condenser fan 2 0 100 S Temp1 Condenser 1 tempe...

Page 29: ... 13 FAN_INTERLOCK 14 FAN_SPACE_FROST 15 FAN_FREEZE 16 FAN_OVERRUN 17 FAN_CYCLING 18 FAN_FAN_ONLY 19 FAN_DEFROST 20 FAN_SENSOR_FAILS 21 FAN_PRESS_CONTROL 22 FAN_TEMP_CONTROL 23 FAN_START_LOGIC 24 FAN_COMPR_ALARM 25 FAN_MIN_OFF_TIME Valve Causes 0 RS_POWER_UP 1 RS_DEFROST 2 RS_OFF_MODE 3 RS_NORMAL 4 RS_COMP_ALARM 5 RS_PRERUN_EXPIRED 6 RS_PRERUN_RUNNING All Automatic The All Automatic function appear...

Page 30: ... if you write to the correct NV e g nviAoManOvr 1 50 An I O which is set to the manual mode is fixed until it is changed using XILON or until any other tool device writes on the override NV nviAoManOvr or nviDoManOvr The Excel Smart I O LonWorks service LED will flash once three seconds ON and 1 second OFF if a module has a value in the manual mode After a power failure the Smart I O module will r...

Page 31: ...093 bin is downloaded into XILON using the Handheld Flash Tool V2 11 file name VC_DL EXE To do this proceed as follows NOTE Before attempting to download the XILON application it is important that the database be completely empty 1 XILON must first be OFF 2 Start XILON by pressing the START key 3 To start the download press the DEL key The following screen appears 1 Download 2 Functional test 3 Fi...

Page 32: ...g on your computer screen Downloading BIOS The BIOS file name e g bios1401 bin is downloaded into XILON using the Handheld Flash Tool V2 11 file name VC_DL EXE To do this proceed as follows 1 XILON must first be OFF 2 Press down the DEL key and keep it pressed 3 Press the START key 4 Start the Handheld Flash Tool V2 11 e g VC_DL EXE bios1401 bin COM1 O2000 5 After completion of the download reset ...

Page 33: ... highest valid values Assigning the addresses in a project successively is the best way to avoid address conflicts The same dialog is used for the domain table menu The only difference is that in the set up dialog the database line is not used For further description of the individual menu items refer also to Menu Domain Table Does XILON work across LON routers Yes it will work across routers but ...

Page 34: ...cess non Honeywell nodes To access such a node you will have to either insert a suitable router see Inserting a Suitable Router below or reconnect your XILON to the network at another location with a compatible communication channel see Reconnecting at a Different Location below Inserting a Suitable Router A router is equipped with two transceivers of different types thus enabling it to transmit n...

Page 35: ... the subnet address requires a good understanding of the network topology Possible Cause Number Six The node which you are attempting to access and your XILON have the same network address Explanation Action Nodes use their network addresses to send messages A node s network address consists of three components 1 the domain to which it belongs 2 the subnet to which it belongs within the domain and...

Page 36: ...n Action Your XILON has crashed Reset your XILON by depressing the reset switch located on the left hand side of the device The reset switch is recessed and can be activated only using a sharp implement e g a ball point pen After resetting your XILON you can turn it back on NOTE Resetting your XILON erases all of the RAM Why does my XILON switch OFF automatically If XILON s display suddenly goes b...

Page 37: ...nal power supply If this corrects the problem we recommend then leaving your XILON switched ON in this condition for two or three hours until the rechargeable battery has been fully recharged Because some components e g the real time clock and the RAM require a constant supply of power in order to function properly the rechargeable battery loses a small amount of charge even when your XILON has be...

Page 38: ...begin a quick charging procedure only if the battery temperature remains below a certain value The display shows the no access screen even though the node is present Db 001 005 0 ERR D no access Possible Cause The node may be unconfigured Explanation Action Use the node info function to determine if the node is online and configured ...

Page 39: ...cket group A group is a logical collection of nodes within a domain A group can contain up to 64 nodes menu toolbar The menu on the XILON Handheld Tool for Wiring Checks when displayed in the form of icons Menu entries can be selected either using cursor keys or by pressing F1 F9 or SHIFT F1 SHIFT F9 The upper row of eight menuscan be selected from anywhere in the operation sequence By pressing ES...

Page 40: ...nputs two analog outputs and four digital outputs XFC 2A06 Honeywell s LONMARK association compliant 230 Vac controller featuring four analog inputs four digital inputs two analog outputs and four digital outputs XFC 3A04 Honeywell s LONMARK association compliant 24 Vac controller featuring four analog inputs four digital inputs two analog outputs and four digital outputs XFC 3A05 Honeywell s LONM...

Page 41: ...XILON HANDHELD TOOL USER GUIDE 41 EN2B 0214GE51 R0503 ...

Page 42: ... English 18 German 18 menu toolbar 18 going to device menu 20 switching back and forth between the toolbar menu and the tree view menu 19 switching OFF from 19 switching OFF from 6 19 menu toolbar definition of 39 menu tree view going to device menu 20 switching back and forth between the toolbar menu and the tree view menu 19 switching OFF from 19 switching OFF from 6 19 menu tree view definition...

Page 43: ...XILON HANDHELD TOOL USER GUIDE 43 EN2B 0214GE51 R0503 ...

Page 44: ...Baker Road Böblinger Straβe 17 manufacturing P O Box 524 North York Ontario D 71101 Schönaich location certified to Minneapolis MN 55408 0524 M2H 3N7 Germany USA Canada http www honeywell com http www honeywell ca http europe hbc honeywell com EN2B 0214GE51 R0503 printed in Germany Subject to change without notice 74 3672 1 ...

Reviews: