background image

ADEMCO 5800RP RF Repeater Module – Installation Instructions

 

INTRODUCTION 

The 5800RP RF Repeater Module consists of an RF receiver and a 
transmitter and is intended to extend the range of 5800 series RF 
devices by 200 feet (nominal). 

The  5800RP  receives  alarm,  status,  and  control  messages  from 
5800 series devices, and forwards these messages to control panel 
connected  receivers  such  as  the  5881EN,  5883,  6128RF,  6150RF, 
and  LYNX  controls.  The  control  then  responds  accordingly 
(arm/disarm the system, initiate an alarm, etc.).  

The  5800RP  also  transmits  it’s  own  status  including  tamper,  AC 
loss  and  RF  jam  detect  via  a  built-in  serial  number  assigned  to  a 
control  panel  zone(s).  Status  is  sent  whenever  a  change  occurs  or 
as part of a supervisory check-in message sent approximately once 
an hour.  

The 5800RP contains a rechargeable battery that provides up to 

6

 

hours of standby operation after primary power is lost. 

The  5800RP  features  a  Spatial  Diversity  system  that  virtually 
eliminates  the  possibility  of  "Nulls"  and  "Dead  Spots"  within  the 
coverage area. 

RECEIVER/

TRANSCEIVER

KEYPAD

TERMINALS

ON CONTROL

BOARD

CONTROL

PANEL*

DATA OUT

DATA IN TO
CONTROL

*CONTROL MUST SUPPORT A 5800 SERIES RF SYSTEM

5800RP

REPEATER

MODULE

POWER IN

5800 SERIES
WIRELESS TRANSMITTER

2-WAY

WIRELESS KEYPAD

(e.g. 5827BD, 5804BD)

OR

5800RL 2-WAY RELAY

MODULE

2-WAY

TRANSMISSION

5800RP_block-00-001-V3

Figure 1.  

Wireless System Overview using 5800RP Repeater Module 

INSTALLING THE 5800RP MODULE 

Mount the 5800RP remotely in its own housing following the steps 
below, and avoid mounting the module with its antennas touching 
a metal surface. 

Check for RF Interference:

 Before mounting permanently, use the 

red RF Interference LED to check for strong local radio frequency 
interference  at  the  intended  mounting  location.  If  this  LED  is 
continuously lit, the 5800RP module should be relocated. 

Removing the Cover:

 

Remove the 5800RP's cover by inserting and 

twisting a screwdriver blade in the slot at the center of the cover's 
lower edge. Note that removing the cover also places the 5800RP in 
the  Go/No  Go  Test  mode.  This  decreases  its  range  during 
installation  to  insure  an  adequate  margin  during  normal 
operation. 

Mounting the Module 

1. For concealed wiring, route power wires through the

rectangular opening at the rear of the base before mounting.
For surface wiring entry, a thin breakaway area is provided
along the base's right edge.

2. Mount the module in the selected location. For greatest

security, use all four mounting holes (two keyslot holes and
two round holes) in the plastic base.

3. Install each antenna in the respective right-hand terminal of

the two terminal blocks at the upper edge of the 5800RP’s
circuit board, and tighten the screws to secure them.

4. Affix the Summary of Connections label to the inside of the

module’s cover. Make sure the arrows and large ‘plus sign’ on
the label line up with the corresponding posts in the cover.

5. If applicable, set the Site ID by referring to the 

Setting the

Site ID

 section on the next page.

Connecting the Power Source  

The  5800RP  is  powered  from  an  AC  external  power  source 
connected to terminals 1 and 2 (see figure 2).  

Power source ratings are as follows: 

Type 

Rating 

Class 2 AC Transformer 

9VAC, 15VA (Honeywell PN 300-07753) 

6. Connect the transformer to the 5800RP’s terminals. Refer to

Figure 2. These terminals are not polarized. The leads from
the AC transformer may be connected to either terminal.
Do not connect to a receptacle controlled by a switch.

NOTE:

 Use of power sources with higher or lower voltages may result 

in damage or failure to operate properly.  

Connecting the Battery

 

7. Begin battery installation by attaching an adhesive backed hook

and loop fastener strip (supplied) to the Summary of Connections
label in the cover. Place the strip within the large box drawing
labeled ‘PLACE BATTERY HERE’. Refer to Figure 2.

8. Attach another adhesive backed hook and loop fastener strip to

the battery. Attach the battery to the cover by firmly pressing
the two hook and loop fastener strips together. Make sure the
battery is positioned as shown in Figure 2.

9. Plug the battery cable into the battery connector on the 5800RP

PCB. Refer to Figure 2.

CHARGING NOTE:

 The battery must be allowed to charge at

least 48 hours in order to reach its full capacity.

10. Replace the cover on the 5800RP, being careful not to pinch the

battery wires between the cover and case or any PCB components.

MOUNTING

HOLES (4)

ANTENNAS

(INSERT IN

RIGHT-HAND

TERMINALS)

5

8

0

0

R

P

_

c

o

n

n

-0

0

-0

0

1

-V

3

MODULE COVER

BATTERY

LIGHTS RED WHEN
SETTING SITE ID

RF INTERFERENCE
RED INDICATOR

DIP SWITCH

ON

OFF

2 3 4 5 6 7 8

1

GRN    YEL    RED

TO
POWER
SUPPLY

TAMPER
SWITCH

WIRING
OPENING

KNOCKOUT
AREA FOR
SURFACE
WIRING

POWER
TERMINALS

BATTERY

CONNECTOR

Figure 2. 

5800RP Repeater Module Layout and Connections 

Summary of Contents for ADEMCO 5800RP

Page 1: ... base before mounting For surface wiring entry a thin breakaway area is provided along the base s right edge 2 Mount the module in the selected location For greatest security use all four mounting holes two keyslot holes and two round holes in the plastic base 3 Install each antenna in the respective right hand terminal of the two terminal blocks at the upper edge of the 5800RP s circuit board and...

Page 2: ...is present PROGRAMMING AND OPERATIONAL NOTES Programming for Combined Trouble Reporting Check in low battery AC loss and RF jam messages all report on one zone 1 Set DIP switch 2 to OFF keep switch 2 in the OFF position when enrolling is complete 2 Assign the 5800RP to a zone for sending check in low battery AC loss and RF jam messages and enroll its serial number When prompted toggle the tamper s...

Page 3: ...d the user s authority to operate the equipment CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may ca...

Page 4: ...ranty information please go to www honeywell com security hsc resources wa 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2004 Honeywell International Inc www honeywell com security ÊK0344V2JŠ K0344V2 1 15 Rev B ...