background image

 

1

 

NOTE:

 It is strongly recommended that any personnel installing 

a Galaxy 2 Series panel undertake appropriate training. A full 
installation manual should be obtained from your branch.  

 

A full technical installation manual will be given to each installer 
at the training session. Additional manuals can be purchased 
from your distributor. 
 
Additionally, the installation manual is available from the 
Honeywell Security website: www.honeywell.com/security 

 

Variants 

The Galaxy 2 Series is available as two different variants. 
The variants are shown in the table below: 
 

Model 

No of zones 
on-board 

Zones 
(MAX) 

STD 
Users* 

2-20 12 

20 

22 

2-44+ 12 

44 

22 

*Excluding Master and Engineer 

 

Setup 

In order to get the system up and running, mount the panel 
and connect and address all peripherals as described 
below, 

before

 finally powering the system. 

Peripheral Wiring 

The following peripherals can be connected to the panel: 
 

RS485 Bus:

 Mk7 LCD Keypad/Keyprox; MAX

3

; RIO; 

PSU; Ethernet Module; RF Portal. 
 

NOTE:

  The system must be wired in a daisy-chain 

configuration. Spur and star configurations must 
not be used. The recommended cable used to 
connect the RS485 (AB) line is twisted pair 
screened cable (Belden 8723 equivalent). 
However, for cable runs of less than 100m in 
normal environments, standard 4-core cable can 
be used. 

Panel Peripheral 

AUX+ + 
AUX– – 

A A 
B B 

RS485 Peripheral Wiring

 

 

ECP Bus (

2–44+

 only): 

6160 Keypad/Keyprox; 5882H 

RF receiver; ECP zone expander. 
 

NOTE:

 Keypads can be wired to the control panel 

independently, in series or in star configuration. The 
maximum total cable length for peripherals connected to 
this line is 100 m. 
 

Panel 

6160 

Keypad 

5800 

Receiver 

ECP 8-Zone 

Expander 

AUX+ 

+ (red) 

+12V I/P 

AUX– – – 

(black) – 

DO Y

V

 DO 

(yellow) DO 

DI G

U

 DI 

(green) DI 

ECP Peripheral Wiring (2-44+ only) 

 

Peripheral Addressing 

The address on most peripherals is set by either jumpers or 
a rotary switch. These must be set 

before

 the system is 

powered up. See the instructions with the peripheral for 
details. 
The following table identifies the available peripheral 
addresses: 

 Valid 

addresses 

Peripheral G2-20 

G2-44+ 

Mk7 Keypad 
& Keyprox 

0, 1, 2, 3 

0, 1, 2, 3 

MAX3** 

0, 1, 2, 3 

0, 1, 2, 3 

RIO 

2, 3, 4, 5 

PSU 

2, 3, 4, 5 

RF Portal* 

4, 5 

4, 5 

6160 Keypad 

0, 1, 2, 3 

 

 

- 0, 

6160 Keyprox 
Keypad 
keyprox 

- 4, 

5882H RF 
Receiver* 

- 4, 

ECP 8-zone 
expander 

- 2, 

3, 

 

Peripheral Addresses     

*

 

Adding one wireless receiver allows all zones to become 

wireless, up to the maximum for the panel type. Adding a second 
receiver allows for greater reception coverage. 

 
** 

The number of MAX

s available on the system is limited to 1. 

 

Mains Supply Wiring 

This product is not suitable for installation, maintenance or 
connection by the user. A competent, qualified engineer, 
with for example NSI approval, must carry out installation 
and maintenance. 

Warning:   A means of isolation from the mains supply 

must be provided within two metres of the 
control panel. Where live and neutral 
supplies can be identified, a fused spur with 
a 3A fuse must be fitted on the live circuit. 
Where live and neutral circuits cannot be 
readily identified, 3A fuses must be fitted to 
both circuits. 

Connect the wires to the mains terminal block in the panel 
as follows: 

 

Blue (neutral) – connect to terminal N 

 

Green/Yellow (earth) – connect to terminal E 

 

Brown (live) – connect to terminal L 

 
 
 

Galaxy 2 Series Quick-start Guide

Summary of Contents for 2-44+

Page 1: ...m total cable length for peripherals connected to this line is 100 m Panel 6160 Keypad 5800 Receiver ECP 8 Zone Expander AUX red 12V I P AUX black DO YV DO yellow DO DI GU DI green DI ECP Peripheral Wiring 2 44 only Peripheral Addressing The address on most peripherals is set by either jumpers or a rotary switch These must be set before the system is powered up See the instructions with the periph...

Page 2: ...to 1004 RIO 1 on board does not have programmable outputs All individual output programming is done in menu 53 Output Wiring The on board outputs are all open collector switched negative The load that is to be controlled by an output should be connected between 12 V and the output terminal Note Output 1002 is set up by default as a 16 ohm speaker driver That means that it gives an AC audio signal ...

Page 3: ...hen A user with sufficient authority has typed their code at the banner and viewed the condition on a keypad any user if Technistore is used If a user is unable to restore an alarm then a manager or engineer will have to be called Code Tampers When enabled see menu option 51 14 Parameters Lockouts and 10 wrong codes are entered in succession the device is locked The lockout lasts for 2 minutes Aft...

Page 4: ...H I 4 g h i 5 J K L 5 j k l 6 M N O Ö ø 6 m n o ö 7 P Q R 7 p q r s 8 T U V 8 t u v ü 9 W X Y 9 w x y z 0 space 0 esc Cancels the edit without saving changes ent Save string entry and exit Deletes character to left of cursor Deletes character at the cursor Communications Built in Comms The Galaxy 2 Series has a built in telephone dialler The incoming telephone line should be wired to the Line In A...

Page 5: ...SU Max total load 1 0 A nominal temp and mains supply 2 44 PSU Max total load 1 4 A nominal temp and mains supply 2 20 Grade 2 Rating 600 mA Max continuous ripple voltage 0 5V at max load 2 44 Grade 2 Rating 1 0 A Max continuous ripple voltage 0 5V at max load Individual 12 V outputs Bell 12 V 500 mA max Both Aux combined 500 mA max Trigger Header 12 V 100 mA max Switched Outputs Trigger Header Ou...

Page 6: ...fective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Honeywell factory service For warranty service return product transportation prepaid to Honeywell Security 6 Aston Fields Road Whitehouse Industrial Estate Runcorn Cheshire WA7 3DL...

Reviews: