background image

Packed in a temporarily assembled condition

Hitachi Plasma Display Ceiling Mount Unit

Model

CMPAT04

Installation Instructions

Thank you for purchasing the Hitachi Plasma Display Ceiling Mount Unit.
To ensure correct usage, please read this instruction manual thoroughly. After reading, please store this manual
in a safe place for future reference.

This plasma display ceiling mount unit is for use only with the following models : CMP401X, CMP402HD, CMP307X

♦  

Special techniques are necessary for installation of
the plasma display.

Do not attempt to perform this work by yourself.

♦  

Request an installation specialist to install this unit.

♦  

This company assumes absolutely no responsibility
for injuries and damages that may occur due to
improper installation and handling.

To dealers and shops

To ensure customer safety, be sure to design the
installation location so that the strength is sufficient
to withstand the weight of both the plasma display
and the Ceiling mount unit.

Always use at least two persons for all
installations.

Firmly install coupling pins, snap pins and screws
as specified in the installation instructions.

Parts Configuration Chart

In the parts packing

Parts for CMP401X only

Coupling pin

X

2

Usage cautions to ensure correct usage

• 

The following symbols are used to ensure safe usage of the product, to prevent danger to

yourself and other parties and to prevent damage to property.

Symbols

This symbol indicates that incorrect handling due to ignoring this symbol
can result in the possibility of personal injury or even death.

This symbol indicates
additional cautions
(including warnings).

This symbol indicates that incorrect handling due to ignoring this symbol
can result in the possibility of personal injury and physical damage.

This symbol indicates
forbidden actions.

This symbol indicates
required actions.

Ceiling mount unit

X

1

Snap pin

X

2

Angle

adjustment unit

X

1

(left)                        (right)

Display mount fitting

1 each left/right

M6 

X

18 screw

X

8

Support

X

2

M4 x 12 screw

X

4

WARNING

CAUTION

Caution

(general)

Forbidden

(general)

Required

(general)

Disassembly

prohibited

Indicates that the power

plug is to be disconnected

from the power outlet.

Summary of Contents for CMPAT04

Page 1: ...use at least two persons for all installations Firmly install coupling pins snap pins and screws as specified in the installation instructions Parts Configuration Chart In the parts packing Parts for CMP401X only Coupling pin X 2 Usage cautions to ensure correct usage The following symbols are used to ensure safe usage of the product to prevent danger to yourself and other parties and to prevent d...

Page 2: ...an cause the plasma display to fall and cause injury Total load of the plasma display ceiling mount unit 51kg Always use bolts washers and nuts to firmly install on a rigid construction member such as ceiling beam etc Do not mount directly on a ceiling of insufficient strength or use wood screws or anchor screws that do not have sufficient strength to reliably resist pulling out When installing th...

Page 3: ...e could elevate and possibly result in fire Injury or damage could also result from falling CAUTION WARNING Make sure the plasma display mount fittings and angle adjustment unit are firmly engaged Failure to do so could cause the plasma display to fall Do not alter any of the parts And do not use broken parts This could result in injury due to the plasma display falling Always use at least two peo...

Page 4: ...cation where the ceiling strength is sufficient Also set the height adjustment position screen tilt angle and horizontal angle of the ceiling mount unit beforehand CMP401X CMP402HD 549 45 45 418 549 307 25 121 940 97 55 366 742 235 180 P60x3 977 583 45 45 451 583 274 25 121 1041 89 55 319 648 314 180 P60x3 969 Screen center Screen center ...

Page 5: ...MP307X Screen center Ceiling mount unit dimensions 330 300 Pipe dia 61mm Four 12mm dia holes 300 330 Adjustment range Height adjustment 180mm P60 x 3 steps Downward tilt angle adjustment 0 5 10 15 20 25 6 steps Horizontal angle adjustment 45 degrees left or right continuous ...

Page 6: ...8 screws Be sure that both the left and right sides are set to the same angle 3 Installing on the ceiling Pass the wiring cable through the ceiling mount unit as necessary Install the ceiling mount unit on the ceiling with the cable hole facing the back For the ceiling use commercially available bolts washers and nuts that are appropriate for the ceiling construction Angle adjustment unit Ceiling ...

Page 7: ...ghten the rotation stopper screw 3 Tighten the 4 lock screws 2 Insert 2 snap pins 1 Insert the 2 coupling pins 4 Adjust the horizontal angle This could cause the plasma display to fall if it is assembled to make the red mark visible Linkage hole Red mark Mounting the display mounting fittings on the plasma display 1 Remove the stand 1 Place a protective sheet cover on the top of a table and place ...

Page 8: ...op hole of the plasma display The 6th display mount hole from the top 2nd display mount hole from the top 4th hole from the top 5th hole from the top Align the protrusion of the support with the outer hole CMP402HD 1 Remove the stand Remove the top case of the cardboard box and the polyethylene bag When a stand is attached to the plasma display remove the four screws and detach the stand 2 Mountin...

Page 9: ...n installation is complete fasten the wiring cable with cable clamps as necessary Make sure that the pins and cutouts at both the top and bottom are firmly engaged Make sure that the angle adjustment unit holes and display mount fitting screw holes are aligned before tightening the screws The plasma display should always be carried by at least two persons Disconnect all of the plasma display power...

Page 10: ...MP307X 330 300 969 601 CMP401X screen center 633 CMP402HD screen center 628 CMP307X screen center Four 12mm dia holes φ61 55 180 P 60 X 3 steps 454 5 degrees X 5 steps 25 degrees Horizontal angle adjustment 45 degrees continuous Vertical tilt angle adjustment 180mm P60mm X 3 steps Printed in Japan JE 3 Digital Media Systems Division 2 15 12 Nishi Shimbashi Minato ku Tokyo 105 8430 Japan Hitachi At...