background image

Manual of medical 

centrifuge

Model:

Please read this manual carefully before use

The company reserves the right to interpret this manual

Please keep the Manual with invoice properly after reading

Product technology or software may subject to upgrade

without prior notice

The appearance of material object shall prevail

Summary of Contents for LX-165T2R

Page 1: ... carefully before use The company reserves the right to interpret this manual Please keep the Manual with invoice properly after reading Product technology or software may subject to upgrade without prior notice The appearance of material object shall prevail ...

Page 2: ...Contents 3 23 ...

Page 3: ...1 Safety Precautions Warning ...

Page 4: ...2 ...

Page 5: ... accessories in case of damage Caution Wrong accessories can lead to safety hazards The use of accessories not recommended by Haier may affect the safety normal function and accuracy of the equipment Damage caused by improper use of accessories by users is not covered by Haier s warranty Warning Do not use this equipment to separate the following substances Do not separate harmful substances Do no...

Page 6: ...4 Cautions Cautions Cautions Cautions Cautions ...

Page 7: ...5 Cautions Cautions Cautions ...

Page 8: ...6 Application scope LX 165 T 2 R 2ml 16500r min Medical Device Classification Catalog ...

Page 9: ...7 Structural characteristics and working principle manually opening cover Transparent ...

Page 10: ...8 Installation and commissioning Cautions ...

Page 11: ...l be stressed uniformly on air input and air output h If the power socket is mounted with grounding wire check whether the grounding condition is good before use engineer technician according to the packing list condition red adjust the experiment table or table till the electronic gradienter bubbles shows green ...

Page 12: ...10 Cautions Cautions ...

Page 13: ...erface of the main machine will display as shown in the Description of operation function interface Instantaneous centrifugation operation centrifuge cover 2 Acceleration program value 2 settings 00 20 00 00 20 00 Alarm information 2020 06 20 09 20 ...

Page 14: ...12 Login Cells Protein 1 2 more Login more ...

Page 15: ...13 ...

Page 16: ...14 WiFi feature is not available on the Overseas model ...

Page 17: ...15 More Basic settings and operation settings ...

Page 18: ...16 ...

Page 19: ...17 Click key and the device starts running till the set temperature is reached You can click key at any time during the process to stop the pre cooling mode Pre cooling settings 1 ...

Page 20: ...y the information of the machine More Information of the machine and help User manual Others More key to return to the previous level key and then the screen will display the code for installation of mobilephone ...

Page 21: ...19 ...

Page 22: ...20 the rotor cover tightly Use and operation Put test samples into centrifugal tubes weigh them with an electronic balance and ensure that the amount and then close the rotor cover tightly 5mm ...

Page 23: ...21 Cautions Cautions ...

Page 24: ...ervice personnel 7 8 of posture sensor 9 10 Temperature sensor fault Damaged sensor or circuit 11 Damaged sensor or circuit 12 Too high temperature inside The temperature inside the refrigeration system sales service personnel Damaged sensor or circuit sales service personnel 13 14 15 16 17 18 19 temperature sensor temperature alarm compressor Damaged sensor or circuit Blocking or poor ventilation...

Page 25: ...23 Repair and maintenance The power switch of the centrifuge is equipped with a built in fuse and the specification is 10A 250V Fuse Fuse ...

Page 26: ...24 1 2 3 4 5 6 7 ...

Page 27: ...25 Circuit diagram CN1 CN3 CN4 CN5 ...

Page 28: ...g range 1s 99h59min59sec 20 40 52dB A AC220V 50 60Hz 480 34 change without notice Specification packing list 1 24 1 5 2 0 16500 25872 2 24 1 5 2 0 15000 21382 3 4 8 0 2 PCR 18891 Sealed angle rotor 4 12 5 21407 Sealed angle rotor 15000 15000 W D H ...

Page 29: ...27 1 1 Set 2 3 4 5 1 5 1 1 ...

Page 30: ...cal Co Ltd Address Haier Industrial Park Economic Technology Development Zone Qingdao P R China Web www haiermedical com Revision Date 04 2021 Version 1st 2021 Dedicated code 0270500000 V13026 Certificate of Quality checker ...

Reviews: