Page 2: ...eiving antenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits Consult the dealer or a...

Page 3: ...nting the Panel 3 Connecting Detection Devices to Panel Zone Inputs 4 Connecting Intrusion Detection Devices 4 Connecting the AC Power Transformer 4 Connecting the Backup Battery Pack 4 Powering Up th...

Page 4: ...15 REARM TIMER 2nd Tier 15 Options 1st Tier 16 KTP ARM 2nd Tier 16 POLICE PANIC 2nd Tier 16 EMERGENCY PANIC 2nd Tier 16 FIRE PANIC 2nd Tier 17 RCVR TROUBLE 2nd Tier 17 PANEL TAMPER 2nd Tier 17 EXIT E...

Page 5: ...2nd Tier 24 PHONE MODULE 2nd Tier 24 Exiting User Programming Mode 24 Downloader Programming 25 ToolBox Downloader Programming 25 Testing the System 25 Basic System Commands 25 Testing Sensors Zones 2...

Page 6: ...iv...

Page 7: ...8 or 13 071 or Wireless Learn Mode Door Window Sen sor 60 362 Wireless Learn Mode PIR Motion Sensor 60 703 95 or 60 639 RECEIVER TROUBLE set to on EXIT DELAY set to 60 seconds or less QUICK EXIT set t...

Page 8: ...rious hardwired detectors Built In Radio Receiver Allows use of up to 20 GE Interlogix 319 5 MHz Crystal and or SAW Learn Mode wireless sensors and touchpads Built In Siren Capable of 85 dB 3m Built I...

Page 9: ...tion then hang the back mounting plate on the screw 7 Recheck for level insert the lower screw and tighten both mounting screws 8 Install the antenna There are three antenna options to choose from Sta...

Page 10: ...attery Pack The panel will receive its primary power from an AC class II transformer In the event of an AC power failure the panel will be powered by a battery pack containing four rechargeable NiCd b...

Page 11: ...l You can program the panel manually using the panel keypad on site Alternately ToolBox downloader software version 5 7 or later allows you to program remotely via a modem and phone line See Downloade...

Page 12: ...after each flash sequence before releasing the tamper switch see Figure 6 To learn the DTIM into the panel 1 Remove the DTIM cover and set it aside 2 Install the antennas See the DTIM Installation In...

Page 13: ...tral monitoring station Phones Menu 1st Tier The PHONES menu lets you set up central station reporting for the Allegro system Phone 1 and Phone 2 2nd Tier Each 2nd tier PHONE menu contains the followi...

Page 14: ...press and hold the 7 key until appears A star is displayed as To enter press and hold the 9 key until appears A pound is displayed as To clear phone number press Quick Exit To program Number 1 or 2 En...

Page 15: ...hether a closing report is sent to the central station When turned on the panel sends a closing report when the system is armed To turn Closings reports on or off under Phone 1 or 2 Press to turn it o...

Page 16: ...g is not accessi ble if a Dealer Code is pro grammed and the Installer Code is used to enter installer pro gramming mode To access the pre dial string option when a Dealer Code is programmed you must...

Page 17: ...old the TEST RESET button until you hear 6 beeps ADD 2nd Tier DEVICES Note To override the preassigned sensor number use the arrow keys to skip to the desired sen sor number Default None When adding d...

Page 18: ...d Table 4 on page 12 shows the words available for each field The default text for zones 2 3 are Zone 2 Front Door Zone 3 Back Door To add text 1 To select the zone you want to add text to press till...

Page 19: ...wnloader phone num ber and with a Downloader code Call waiting services should be disabled to prevent interrupting panel communication to the down loader To program a dialing prefix that disables call...

Page 20: ...arameters 4 digits 0 9 The duress code is a unique 4 digit access code that allows users to operate the system and at the same time instructs the panel to send a silent alarm report to the central sta...

Page 21: ...days Set this option to 0 to turn off To set the Auto Phone Test Press enter desired number of days and then press QUIET TIME 2nd Tier TIMERS Important Fire related trouble beeps are not affected by...

Page 22: ...s are enabled on or disabled off If enabled an immediate Police alarm will occur after the police panic buttons are pressed for two seconds and the panel displays the alarm as a police panic If the DT...

Page 23: ...the panel will display a status mes sage only To turn the panel tamper on or off Press to turn on or off EXIT EXT 2nd Tier OPTIONS Default on UL installations off When Exit Extension is on the panel...

Page 24: ...er arms the system without exiting the premises This can help prevent accidental alarms by deactivating interior motion sensors during occupied arming periods When this feature is on and the system is...

Page 25: ...ork exactly as on the production version except those listed here To put the panel into demo kit mode 1 Press to turn Demo Kit on 2 Clear the panel memory see Clear Memory 1st Tier on page 21 The powe...

Page 26: ...The panel sends a packet to the DTIM informing it to send a phone test report to the central station The report will be sent out immediately The DTIM will send a successful or failed phone test messa...

Page 27: ...d To begin a downloader session Press until EXIT DL is displayed and then enter installer dealer or primary code to start a Downloader session User Programing Menu Items This section guides you throug...

Page 28: ...to 9 The maintenance code is to be used in conjunction with the apartment manager keychain touchpad When a maintenance person needs access to a site protected by an Allegro he can press disarm on the...

Page 29: ...is set to a lower level Panel will automatically leave sensor test after 15 minutes Warning beeps will sound the last minute The panel will display TEST DONE when all sensors have been tested To run a...

Page 30: ...mode Press until EXIT is displayed and then press The current time will be displayed PANEL 2nd Tier VERSION This setting allows the user to display the panel software and hardware version installed T...

Page 31: ...oes not exist the user or ToolBox operator sim ply calls the panel location once and listens for 10 rings The panel should answer after the tenth ring For off site access where an answering machine ex...

Page 32: ...Q u i c k E x i t 1 A r m N o D e l a y 4 D i s a r m C h i m e 7 S i l e n t Table 6 Sensor Tripping Instructions Sensor Do This Number of Beeps DTIM Initiate a sensor test 7 8 Door Window Open the...

Page 33: ...r s battery and replace the sensor Testing Phone Communication Perform a phone test to check the phone communication between the panel and the central moni toring station See PHONE TEST 1st Tier on pa...

Page 34: ...t the battery voltage is only monitored during a backup battery test The panel auto matically runs a two minute backup battery test under the following conditions 1 during user sensor test 2 once ever...

Page 35: ...alarm initiate a sensor test and then replace the indicated device battery After replacing the battery perform another sensor test to test the sensor touchpad Note If the sensor touchpad is not tested...

Page 36: ...nd learn sensor into memory maximum zones 20 6 Sensor may be out of range Move sensor to another location Sensor reports trouble and open condition 1 Sensor tamper switch is tripped sensor cover is of...

Page 37: ...s signal may not be reaching the panel because it is too far away from the panel or there is too much interference 1 Remove the DTIM from its mounted location and test from other locations 2 Mount th...

Page 38: ...to verify communication between the DTIM and panel See Phone Test 2nd Tier on page 23 Downloader Download upload session fails on a pre programmed panel 1 Verify Downloader Phone Number matches ToolB...

Page 39: ...nt Interior Interior doors Police Follower 2 3 15 Instant Interior Interior PIR motion sensors Police Follower 2 3 16 Instant Interior Interior doors Police Follower 3 17 Instant Interior PIR motion s...

Page 40: ...sensor of this type will cause an immediate alarm if the violation occurs during an active arming level Follower A sensor of this type will cause an immediate alarm if a violation occurs during an act...

Page 41: ...Trouble Off On for UL off on Panel Tamper On off on Exit EXT On Off for UL off on Swinger Shutdown 1 1 2 Quick Arm Off off on Quick Exit On Off for UL off on Auto Stay Arm On off on Supv Time Random...

Page 42: ...Appendix B Reference Tables 36 Table B9 Sensor Information Sensor Number Sensor Text Sensor Type Sensor Group 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20...

Page 43: ...none 30 sec 15 120 none none 4 digits 4 digits 4 digits 4 digits 4 digits Exit Dly 60 Sec 45 254 Auto Phn Test 0 Off 0 255 Quiet Time On Off Quiet Hour 22 0 23 Rearm Timer 0 0 12 KTP Arm Police Panic...

Page 44: ...cy 319 5 MHz or 140 kHz Nominal Range 500 feet 150 m open air receiving range Temperature Range Storage 30 to140 F 34 to 60 C Operating 32 to 122 F 0 to 49 C Maximum Humidity 90 relative humidity nonc...