Page 1: ...C120 E285 10ENZ2 FUJITSU ULTRA LVD SCSI Host Bus Adapter Driver 3 0 User s Guide for Oracle Solaris ...

Page 2: ...o deal with problems Appendix A Messages The appendix lists messages displayed by the driver Appendix B PCI slot number and device name The appendix shows correspondence between PCI slot number and device name Scope The extent of procedures in this guide is to enable SCSI to recognize connected SCSI devices For instructions on formatting writing a disk label and defining a partition after recognit...

Page 3: ...ion The contents of this manual shall not be disclosed in any way or reproduced in any media without the express written permission of Fujitsu Limited The contents of this manual may be revised without prior notice All Rights Reserved Copyright C FUJITSU LIMITED 2007 2011 ...

Page 4: ...2007 First Edition 2 Apr 9 2007 Add 914572 01 patch 3 Jun 13 2007 Add 914572 02 patch 4 May 16 2008 Add 914572 05 patch 5 Sep 2 2008 Support SAS card SE0X7SA1X Add 914572 06 patch 6 Jan 8 2010 Changed the Version 3 0 7 Oct 27 2011 Support SPARC Enterprise Software DVD ...

Page 5: ...ty setting 8 2 2 2 Property setting for each port 8 2 2 3 max throttle property setting 8 2 3 Configuring I O devices 10 2 3 1 Collecting infomation about the devices to be connected 10 2 3 2 Editing the sd conf 10 2 3 3 Editing the ses conf File Unit 11 2 3 4 Reconfiguring the kernel 12 2 4 Network Install 13 Chapter 3 Troubleshooting 14 Appendix A Messages 16 A 1 Warning messages 17 A 2 PANIC me...

Page 6: ... following Functions of Fujitsu ULTRA LVD SCSI Host Bus Adapter Driver 3 0 Specification for the SCSI card supported by Fujitsu ULTRA LVD SCSI Host Bus Adapter Driver 3 0 Specification for the SAS card supported by Fujitsu ULTRA LVD SCSI Host Bus Adapter Driver 3 0 ...

Page 7: ...hapter 1 Overview 2 1 1 Function Overview Fujitsu ULTRA LVD SCSI Host Bus Adapter Driver 3 0 is a SCSI SAS host bus adapter HBA driver Figure 1 1 Form of SCSI connection Figure 1 2 Form of SAS connection ...

Page 8: ...pin Transfer rate Async mode Maximum 7MB s per SCSI port Sync mode Maximum 320 MB s per SCSI port Maximum Cable Length 12m Number of SCSI devices Up to 14 per SCSI port Multi Initiator Support Number of Initiator Maximum 2 per SCSI port Table 1 2 PCI X bus specifications Specification compliance PCI X 1 0 Bus width 64 bit Operating clock 133 MHz Card form Low profile MD2 Bracket form Standard Brac...

Page 9: ...s that it is a SCSI bus Port B is a LVD SCSI VHDCI connector FJSV e ulsa 1 indicates that it is a SCSI bus is a variable representing the PCI slot location of this card Figure 1 3 Top view of the Ultra320 SCSI card SE0X7SC1X Figure 1 4 Top view of the Ultra320 SCSI card SE0X7SC2X ...

Page 10: ...Attached SCSI Transfer rate Max 3 0 Gbps x 4 Medium Interface Specification compliance SAS 1 1 3Gbps Connector SAS x4 connector Maximum Cable Length Max 6 m Table 1 5 PCI Express specification Specification compliance PCI Express Line speed 2 5Gbps Number of lane x4 Card form Low profile MD2 Bracket form Standard Bracket 1 2 2 2 Physical description Figure 1 5 show the top of the SAS cards The dif...

Page 11: ...apter explains the tasks required after installation of this software so that SCSI SAS target driver can recognize devices Explanations of tasks are given in the following sequence Installing the driver Configuring the driver software Configuring I O devices ...

Page 12: ...e Driver To use FUJITSU ULTRA LVD SCSI Host Bus Adapter Driver 3 0 install the package stored on the SPARC Enterprise Software DVD For the installation procedure refer to the Installation Guide FUJITSU ULTRA LVD SCSI Host Bus Adapter Driver 3 0 ...

Page 13: ...CSI SAS card port is pci 1d 4000 FJSV e ulsa 3 specify pci 1d 4000 The device number of the SCSI SAS card in the device name is specified for of the unit address property For example if a device name shows that the SCSI SAS card port is pci 1d 4000 FJSV e ulsa 3 specify 3 immediately following FJSV e ulsa In the following example the disable u320 is set to 0x1 for the port of an Ultra320 SCSI SAS ...

Page 14: ...the platform sun4v SUNW SPARC Enterprise kernel drv fjulsa conf file makes the target max throttle property effective target max throttle SCSI ID Number of data transfer requests which can be issued at the same time In the following example the number of data transfer requests that can be issued at the same time to a device with SCSI ID 1 is limited to 128 target1 max throttle 128 For information ...

Page 15: ...n the device with which the server for the installation is connected by executing probe scsi all on OBP can be confirmed 0 ok probe scsi all pci 7 700000 FJSV eulsa 0 MPT Version 01 05 Firmware Version 01 24 00 00 SAS World Wide ID HBA Port0 is 0x500605b0 003cf854 Target 0x1c Unit 0x0 Disk FUJITSU E2000 0000 2097152 Blocks 1073 MB Unit 0x1 Disk FUJITSU E2000 0000 2097152 Blocks 1073 MB 2 3 2 Editi...

Page 16: ... driver now has all the necessary definitions 2 3 3 Editing the ses conf File Unit The definition file for the ses driver is kernel drv ses conf add the collected information to this file ses conf contains several default settings A definition begins with name ses and ends with a semicolon target X specifies a SCSI target ID lun X specifies a logical unit number A line starting with a number sign ...

Page 17: ...o take effect in the kernel reboot the machine as follows touch reconfigure usr sbin shutdown i6 g0 y The sd driver can now recognize the SCSI devices Use the format command to check the recognition results Next write a disk label or define a partition with the formatting command as explained in the manual for each device ...

Page 18: ...tall the driver in the server connected to this SCSI SAS card with an installation server Please refer to the following manual when the target machine of the network installation is SPARC Enterprise Install Server Build Guide I O device driver SPARC Enterprise ...

Page 19: ...Chapter 3 Troubleshooting 14 Chapter 3 Troubleshooting Check the following if a problem occurs ...

Page 20: ... is turned off and then on again If a device is not correctly identified even though its configuration is correct turn the device off and then on again Does the SCSI bus have duplicate SCSI IDs If the Initiator ID and SCSI ID for a device are the same on a SCSI bus correct SCSI bus operation is not possible In this event check the Initiator ID and SCSI ID of the device Methods of identifying the c...

Page 21: ...Appendix A Messages 16 Appendix A Messages ...

Page 22: ...port representative WARNING pci FJSV e ulsa fjulsa ulsa_config_space_init failed Initialization of PCI configuration register went wrong into attach of the fjulsa driver Please refer to the following columns WARNING pci FJSV e ulsa fjulsa cannot map configuration space WARNING pci FJSV e ulsa fjulsa not supported vendor ID WARNING pci FJSV e ulsa fjulsa LSILogic PCI device 1000 not supported WARNI...

Page 23: ...sentative WARNING pci FJSV e ulsa fjulsa creating minor node failed Control information could not be created while the fjulsa driver was being attached Installed memory may be insufficient If the amount of memory does not seem to be the problem contact a support representative WARNING pci FJSV e ulsa fjulsa Target disabled TQ since disconnects are disabled The TAG setting was invalidated because d...

Page 24: ...amount of memory does not seem to be the problem contact a support representative WARNING pci FJSV e ulsa fjulsa ulsa_request_msg_init failed An area for request messages could not be allocated while the fjulsa driver was being attached Installed memory may be insufficient If the amount of memory does not seem to be the problem contact a support representative WARNING pci FJSV e ulsa fjulsa attach...

Page 25: ... be allocated Installed memory may be insufficient If the amount of memory does not seem to be the problem contact a support representative WARNING pci FJSV e ulsa fjulsa chip reset failed Chip reset processing failed Replace the adapter Contact customer support WARNING pci FJSV e ulsa fjulsa IOC not come to READY state The SCSI SAS control chip could not be changed to the READY state after chip r...

Page 26: ...stomer support WARNING pci FJSV e ulsa fjulsa invalid context reply reply An invalid context reply was received Contact customer support WARNING pci FJSV e ulsa fjulsa invalid address reply addr An invalid address reply was received Contact customer support WARNING pci FJSV e ulsa fjulsa IOC received invalid SGL The SCSI SAS control chip received an invalid scatter gather list Contact customer sup...

Page 27: ...ult Contact customer support WARNING pci FJSV e ulsa fjulsa invalid task termination interrupt An invalid task termination interrupt was detected Contact customer support WARNING pci FJSV e ulsa fjulsa Resetting scsi bus IOC found SCSI bus error from target A SCSI SAS bus error was detected during target control The SCSI SAS bus was reset The SCSI SAS unit and cable may have a fault Contact custom...

Page 28: ...pci FJSV e ulsa fjulsa Reset History did not clear The SCSI SAS control chip history could not be cleared Contact customer support WARNING pci FJSV e ulsa fjulsa Target disabled wide SCSI mode Wide SCSI transfer of the target was invalidated Contact customer support WARNING pci FJSV e ulsa fjulsa Target reverting to async Mode The target is transferred asynchronously Contact customer support WARNI...

Page 29: ...ccurred status An error occurred on the PCI bus Contact customer support WARNING pci FJSV eulsa fjulsa first chip reset failed First SCSI SAS Control chip reset failed Contact customer support WARNING pci FJSV eulsa fjulsa invalid base wwid SAS base wwid invalid Contact customer support WARNING pci FJSV eulsa fjulsa get base wwid failed SAS base wwid failed Contact customer support WARNING pci FJS...

Page 30: ...sa timeout on SAS IO Unit Control message interrupt An SAS IO Unit Control message interrupt timeout occurred because an error of SAS control chip is faulty Contact customer support WARNING pci FJSV eulsa fjulsa getting interrupt type failed Getting interrupt type failed Contact customer support WARNING pci FJSV eulsa fjulsa MSI interrupt is unsupported Fjulsa driver is not support MSI Contact cus...

Page 31: ...ting interrupt resource failed Contact customer support WARNING pci FJSV eulsa fjulsa getting interrupt priority failed Getting interrupt resource failed Contact customer support WARNING pci FJSV eulsa fjulsa adding interrupt handler failed Adding interrupt handler failed Contact customer support ...

Page 32: ... that has already been reallocated Upper driver is faulty Contact customer support PANIC pci FJSV e ulsa fjulsa timeout on bus reset interrupt A timeout occurred during a bus reset interrupt The SCSI unit and cable may have a fault Contact customer support PANIC pci FJSV e ulsa fjulsa invalid queue entry cmd The fjulsa driver s internal contradiction was detected Contact customer support PANIC pci...

Page 33: ...r mode if s is Async and ss is Narrow When either mode is not supported no problem occurred When either mode is supported contact customer support pci FJSV e ulsa fjulsa ulsa_hbaq_delete target was on hbaq times More than one logical unit is registered with hbaq No problem occurred pci FJSV e ulsa fjulsa function done IOCStatus IOCLogInfo Unexpected status was notified from SCSI control chip pci F...

Page 34: ...C stat WARNING pci FJSV e ulsa fjulsa command timeout for Target WARNING pci FJSV e ulsa fjulsa timeout on EventAck message interrupt pci FJSV e ulsa fjulsa pkt_flags pkt_statistics pkt_state Information regarding timeout Follow the instructions given in the following message WARNING pci FJSV e ulsa fjulsa IOC message timeout occurred IOC stat WARNING pci FJSV e ulsa fjulsa command timeout for Tar...

Page 35: ...The supported SCSI card was detected No problem occurred fjulsa is pci FJSV e ulsa The fjulsa driver was attached No problem occurred pci FJSV e ulsa fjulsa LSILogic LSISAS1068E found The supported SAS card was detected No problem occurred pci FJSV e ulsa fjulsa fjulsa Initiator WWNs 0x 0x WWN of the SAS card is displayed No problem occurred ...

Page 36: ...nd Device Name 31 Appendix B PCI Slot Number and Device Name The appendix provides the PCI slot number and device name matrix for the following SUNW SPARC Enterprise models SPARC Enterprise M4000 M5000 SPARC Enterprise M8000 M9000 ...

Page 37: ...1 4 PCI 2 PCIX5 pci 1 700000 pci 0 pci 8 pci 0 4 PCI 2 PCIX6 pci 1 700000 pci 0 pci 8 pci 0 1 4 PCI 2 PCIX3 pci 1 700000 pci 0 pci 9 pci 0 4 PCI 2 IOBoat X PCI 2 PCIX4 pci 1 700000 pci 0 pci 9 pci 0 1 4 PCI 2 PCIE1 pci 1 700000 pci 0 pci 1 pci 0 pci 0 0 PCI 2 PCIE2 pci 1 700000 pci 0 pci 1 pci 0 pci 1 0 PCI 2 PCIE3 pci 1 700000 pci 0 pci 1 pci 0 pci 9 0 PCI 2 PCIE4 pci 1 700000 pci 0 pci 9 pci 0 p...

Page 38: ...i 0 pci 1 0 PCI 1 PCIE3 pci 10 600000 pci 0 pci 9 pci 0 pci 1 pci 0 pci 9 0 PCI 1 PCIE4 pci 10 600000 pci 0 pci 9 pci 0 pci 9 pci 0 pci 0 0 PCI 1 PCIE5 pci 10 600000 pci 0 pci 9 pci 0 pci 9 pci 0 pci 1 0 PCI 1 IOBoat Ex PCI 1 PCIE6 pci 10 600000 pci 0 pci 9 pci 0 pci 9 pci 0 pci 9 0 Basic PCI Slot PCI 2 pci 11 700000 0 PCI 2 PCIX1 pci 11 700000 pci 0 pci 1 pci 0 4 PCI 2 PCIX2 pci 11 700000 pci 0 p...

Page 39: ...ber Device Name Basic PCI Slot PCI 0 pci 0 600000 0 Basic PCI Slot PCI 1 pci 1 700000 0 PCI 1 PCIX1 pci 1 700000 pci 0 pci 1 pci 0 4 PCI 1 PCIX2 pci 1 700000 pci 0 pci 1 pci 0 1 4 PCI 1 PCIX5 pci 1 700000 pci 0 pci 8 pci 0 4 PCI 1 PCIX6 pci 1 700000 pci 0 pci 8 pci 0 1 4 PCI 1 PCIX3 pci 1 700000 pci 0 pci 9 pci 0 4 PCI 1 IOBoat X PCI 1 PCIX4 pci 1 700000 pci 0 pci 9 pci 0 1 4 PCI 1 PCIE1 pci 1 700...

Page 40: ...sic PCI Slot PCI 7 pci 7 700000 0 PCI 7 PCIX1 pci 7 700000 pci 0 pci 1 pci 0 4 PCI 7 PCIX2 pci 7 700000 pci 0 pci 1 pci 0 1 4 PCI 7 PCIX5 pci 7 700000 pci 0 pci 8 pci 0 4 PCI 7 PCIX6 pci 7 700000 pci 0 pci 8 pci 0 1 4 PCI 7 PCIX3 pci 7 700000 pci 0 pci 9 pci 0 4 PCI 7 IOBoat X PCI 7 PCIX4 pci 7 700000 pci 0 pci 9 pci 0 1 4 PCI 7 PCIE1 pci 7 700000 pci 0 pci 1 pci 0 pci 0 0 PCI 7 PCIE2 pci 7 700000...

Page 41: ... 5 PCIX1 pci 15 700000 pci 0 pci 1 pci 0 4 PCI 5 PCIX2 pci 15 700000 pci 0 pci 1 pci 0 1 4 PCI 5 PCIX5 pci 15 700000 pci 0 pci 8 pci 0 4 PCI 5 PCIX6 pci 15 700000 pci 0 pci 8 pci 0 1 4 PCI 5 PCIX3 pci 15 700000 pci 0 pci 9 pci 0 4 PCI 5 IOBoat X PCI 5 PCIX4 pci 15 700000 pci 0 pci 9 pci 0 1 4 PCI 5 PCIE1 pci 15 700000 pci 0 pci 1 pci 0 pci 0 0 PCI 5 PCIE2 pci 15 700000 pci 0 pci 1 pci 0 pci 1 0 PC...

Page 42: ...Appendix B PCI Slot Number and Device Name 37 Board Number Slot Number Device Name PCI 7 PCIE5 pci 17 700000 pci 0 pci 9 pci 0 pci 1 0 PCI 7 PCIE6 pci 17 700000 pci 0 pci 9 pci 0 pci 9 0 ...