INSTALLATION MANUAL

INSTALLATION MANUAL

For authorized service personnel only.

INSTALLATIONSANLEITUNG

Nur für autorisiertes Personal.

MANUEL D’INSTALLATION

Pour le personnel agréé uniquement.

MANUAL DE INSTALACIÓN

Solo para personal autorizado.

MANUALE D’INSTALLAZIONE

Ad uso esclusivo del personale autorizzato.

ΕΓΧΕΙΡΙΔΙΟ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

Για

 

εξουσιοδοτημένο

 

προσωπικό

 

σέρβις

.

MANUAL DE INSTALAÇÃO

Apenas para técnicos autorizados.

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

Для

 

уполномоченного

 

персонала

.

KURULUM KILAVUZU

Yetkili servis personeli içindir.

AIR CONDITIONER
INDOOR UNIT
Floor Type

PART NO. 9378533028-03

9378533028-03_IM.indb   1

9378533028-03_IM.indb   1

2011-10-08   11:08:01

2011-10-08   11:08:01

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for agyg09lvca

Page 1: ...l autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir AIR CONDITIONER INDOOR UNIT Floor Type PART NO 9378533028 03 9378533028 03_IM indb 1 9378533028 03_I...

Page 2: ...pecially when replacing a conventional refrigerant R22 model with a new refrigerant R410A model always replace the conventional piping and flare nuts with the R410A piping and flare nuts Models that use refrigerant R410A have a different charging port thread diameter to prevent erroneous charging with conventional refrigerant R22 and for safety Therefore check beforehand The charging port thread d...

Page 3: ...he entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning 1 3 1 Type of copper pipe and insulation material CAUTION Refer to the installation manual for the outdoor unit for description of allowable pipe length and height difference MODEL Diameter Liquid pipe Gas pipe 9 000 Btu h model 6 35 mm 1 4 in 9 52 mm 3 8 in ...

Page 4: ...the upper or lower air outlet is blocked the air conditioner will not be able to cool or warm the room well Do not block the receiver with the grating Otherwise the grating will interfere with the remote controller signal and significantly reduce the distance and area angle from which the signals can be received Use a grating with vertical bars etc that has at least 75 open area If the grating has...

Page 5: ...ccording to the direction of piping Rear piping Left piping Center of wall holl 130 mm Floor 280 mm 245 mm Back wall 100 mm Back wall 690 mm Right piping 30 mm Back wall 6 6 Note on drain hose CAUTION Insert drain hose and drain cap securely Drain should slope down to avoid water leakage When inserting be sure not to attach any material besides water If any other material is attached it will cause...

Page 6: ...rm the flare processing with a flare tool Use the special R410A flare tool or the conventional flare tool Leakage of refrigerant may result if other flare nuts are used 4 Protect the pipes by pinching them or with tape to prevent dust dirt or water from entering the pipes L Check if L is flared uniformly and is not cracked or scratched Pipe Die Pipe outside diameter mm in Dimension A mm Dimension ...

Page 7: ...e tool so that the wires do not come loose Strip 10 mm Sleeve Crimp type terminal 3 Use the specified wires connect them securely and fasten them so that there is no stress placed on the terminals 4 Use an appropriate screwdriver to tighten the terminal screws Do not use a screwdriver that is too small otherwise the screw heads may be damaged and prevent the screws from being properly tightened 5 ...

Page 8: ...supply Insulated connection Check the following GOOD NO GOOD NO GOOD Accumulated drain water No upward slope 50 mm or less from earth ground Stopping downward No upward slope End of drain hose is immersed in water Drainage channel Air NO GOOD NO GOOD NO GOOD 9 TEST RUN WARNING Do not turn on the power until all installation work is complete CAUTION When restarting after a long period of disuse in ...

Page 9: ...mode STEP 1 Selecting the Remote Controller Signal Code Use the following steps to select the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code The signal codes that are set through this process are applicable only to the signals in the FUNCTION SETTING For details on how to set the signal cod...

Page 10: ...ption Function Number Setting Value Yes 40 00 No 01 Auto restart is an emergency function such as for power failure etc Do not start and stop the indoor unit by this function in normal operation Be sure to operate by the control unit or external input device Indoor room temperature sensor switching function Only for Wired remote controller The following settings are needed when using the Wired rem...

Page 11: ...ter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor e...