To avoid the possibility of personal injury and/or property damage, it is important that safe servicing practices be
observed. The following are some limited examples of safe practices.

1.

Do not attempt a product repair if you have any doubts as to your ability to complete it in a safe and satisfactory
manner.

2.

Before servicing or moving an appliance, remove power cord from electric outlet, trip circuit
breaker to Off, or remove fuse.

3.

Never interfere with the proper installation of any safety device.

4.

USE ONLY REPLACEMENT PARTS CATALOGED FOR THIS APPLIANCE. SUBSTITUTIONS MAY DEFEAT COMPLIANCE
WITH SAFETY STANDARDS SET FOR HOME APPLIANCES.

5.

GROUNDING: The standard color coding for safety ground wires is GREEN OR GREEN WITH YELLOW STRIPES.
Ground leads are not to be used as current carrying conductors. IT IS EXTREMELY IMPORTANT THAT THE SERVICE
TECHNICIAN REESTABLISH ALL SAFETY GROUNDS PRIOR TO COMPLETION OF SERVICE. FAILURE TO DO SO
WILL CREATE A POTENTIAL HAZARD.

6.

Prior to returning the product to service, ensure that:

All electric and gas connections are correct and secure.

All gas connections are tested for leaks. DO NOT TEST FOR GAS LEAKS WITH A FLAME.

All electrical leads are properly dressed and secured away from sharp edges, high-temperature components,
and moving parts.

All uninsulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal
parts and panels.

All safety grounds (both internal and external) are correctly and securely reassembled.

All panels are properly and securely reassembled.

SERVICE DATA SHEET

    318047420 (0606)  Rev. A

Gas & Electric Ovens with Electronic Oven Control  (

ES 100)

SAFE SERVICING PRACTICES

NOTICE

This service data sheet is intended for use by persons having electrical and mechanical training and a level of
knowledge of these subjects generally considered acceptable in the appliance repair trade. 

The manufacturer

cannot be responsible, nor assume any liability, for injury or damage of any kind arising from the use of
this data sheet.

Summary of Contents for FEB24S2ASC

Page 1: ...COMPLETION OF SERVICE FAILURE TO DO SO WILL CREATE A POTENTIAL HAZARD 6 Prior to returning the product to service ensure that All electric and gas connections are correct and secure All gas connections are tested for leaks DO NOT TEST FOR GAS LEAKS WITH A FLAME All electrical leads are properly dressed and secured away from sharp edges high temperature components and moving parts All uninsulated e...

Page 2: ...ements use full power when they are on but they are never on at the same time Gas Models Only the bake element is used all the time NORMAL BAKE ES100 ELECTRONIC OVEN CONTROL Note The ES100 s are not field repairable Note Depending on model the size and shape of touch pads may vary for example round instead of elliptical OVEN CALIBRATION Set the electronic oven control for normal baking at 350 F Ob...

Page 3: ...ts F31 Shorted RTD sensor probe wiring problem Note F30 or F31 is displayed when oven is in active mode or an attempt to enter an active mode is made Check RTD sensor probe and replace if necessary If oven is overheating disconnectpower Ifovencontinuestooverheat when power is reapplied replace power relay board and or display board Severe overheating may require the entire oven to be replaced shou...

Page 4: ...LYSIS MATRIX Function Bake Broil Bake Element X Broil Element X X Electric Models CIRCUIT ANALYSIS MATRIX Function Bake Broil Bake Element X Gas Models X ELECTRICAL RATING 24 Electric Models Kw Rating 240 208V Bake Element Wattage Broil Element Wattage 3 4 2 5 2100W 1577W 3400W 2554W ELECTRICAL RATING 30 Electric Models Kw Rating 240 208V Bake Element Wattage Broil Element Wattage 3 0 2 3 3000W 22...

Page 5: ...ón adecuada de un aparato 4 UTILICE SOLAMENTE EL CATALOGO DE PIEZAS DESIGNADO PARA ESTE APARATO EL SUBSTITUIRLAS PODRIA ESTAR EN DESACUERDO CON LAS MEDIDAS NECESARIAS PARA LOS APARATOS DE CASA 5 PUESTA A TIERRA los cables de seguridad a tierra son VERDES CON LINEAS AMARILLAS Los cables de tierra no pueden ser utilizados como conductores ES MUY IMPORTANTE QUE EL TECNICO ESTABLEZCA LA SEGURIDAD DE L...

Page 6: ... potencia cuando están encendidos pero nunca están encendidos los dos al mismo tiempo Modelos Gas 100 del tiempo en modo Hornear HORNEO NORMAL CALENTAMIENTO INICIAL Es normal de ver la temperatura exceder la norma durante ell calentamiento inicial de todos los modos cuando controle la temperatura T t sec Ajuste de punto Exceso de la normo inicial de calentamiento CALIBRACION DEL HORNO Ajuste el co...

Page 7: ...ota Se exhibe F30 o F31 cuando el horno está en modo activo o se hace una tentativa de entrar en un modo activo Verifique el sensor RTD y remplácelo si es necesario Si el horno se esta sobrecalentando desconéctelo Si el horno continúa a sobrecalentarse remplace el panel de relevadores o el panel de control análogo Un sobrecalentamiento extremo necesitara el reemplazo del horno entero si el daño fu...

Page 8: ...IÓN ELECTRICÁ Modelos Eléctrica 24 Kw Calibración 240 208V Vatio de Elemento para Hornear Vatio de Elemento para Asar 3 4 2 5 2100W 1577W 3400W 2554W CALIBRACIÓN ELECTRICÁ Modelos Eléctrica 30 3 0 2 3 3000W 2253W 2750W 2066W CALIBRACIÓN ELECTRICÁ Modelos Eléctrica 40 3 0 2 3 3000W 2253W 2750W 2066W Indica un elemento convencional alternado con elemento de hornear MATRIZ DE ANÁLISIS DE CIRCUITO Mod...