background image

 

 

 

G2-2 Series AS-i

 

Quick Start Manual 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

Page 1 

 

3835051 TDG22ASQS1-4 

    

9/06 

Subject to change without notice 

 

www.numatics.com/fieldbus

 

Getting Started

 

 

This is a brief document designed to quickly get you started setting up your valve manifold with an integrated 
Numatics’ G2-2 AS-i communication node.   

 

1) Initial Unpacking and Inspection 

 

1)

 

Examine exterior of package for signs of damage.  Report any damage to shipping carrier. 

 

2)

 

Remove wrapped manifold assembly from box. 
a)

 

Remove manifold assembly from anti-static packaging 

b)

 

Retain documentation for installation and configuration 

 

3)

 

Examine manifold assembly for any shipping damage such as: 
a)

 

Bent pins or connectors 

b)

 

Report any damage to shipping carrier immediately 

 

4)

 

Examine manifold assembly for proper ordered configuration. (Valves, I/O, Protocol, etc.)   

 
2) G2-2 Introduction 

 

Below is an example of a 2012 series valve manifold.  This fieldbus manifold series is capable of addressing a 
total of up to 16 Inputs and 16 Outputs (using 4 separate AS-i addresses. This would include 16 valve outputs 
and 16 input connectors, which are located on the top of the AS-i modules. There are 14 AS-i configurations 
currently available. Each of the configurations is available in both standard and extended addressing and 
contain different configurations of inputs and outputs. Also located on the top of the AS-i modules are two flat 
cable connectors: a 2-pin communication connector (yellow cable) and a 2-pin Aux. power connector (black 
cable).  These connectors are labeled accordingly. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Numatics G2-2 AS-i

Page 1: ...nectors b Report any damage to shipping carrier immediately 4 Examine manifold assembly for proper ordered configuration Valves I O Protocol etc 2 G2 2 Introduction Below is an example of a 2012 series valve manifold This fieldbus manifold series is capable of addressing a total of up to 16 Inputs and 16 Outputs using 4 separate AS i addresses This would include 16 valve outputs and 16 input conne...

Page 2: ...n Part Number Standard Addressing Valve Output Board 256 836 Extended Addressing Valve Output Board 256 907 Cover Assembly with 0 Inputs 205 329 Cover Assembly with 4 Inputs 205 330 Insulation Displacement Cover Assembly with 8 Inputs 205 331 AS i Complete Communication Module I O Chart Standard Addressing 239 2055 Standard Addressing 239 2058 Standard Addressing 239 2056 Available Outputs 4 Avail...

Page 3: ...ailable Outputs 6 Available Outputs 9 Available Inputs 4 Available Inputs 8 Available Inputs 0 Number of addressable nodes 2 Number of addressable nodes 2 Number of addressable nodes 3 Standard Addressing 239 2181 Standard Addressing 239 2231 Standard Addressing 239 2232 Available Outputs 12 Available Outputs 12 Available Outputs 12 Available Inputs 4 Available Inputs 8 Available Inputs 12 Extende...

Page 4: ... Extended Addressing 239 2168 Extended Addressing 239 2167 Available Outputs 12 Available Outputs 12 Available Outputs 12 Available Inputs 0 Available Inputs 4 Available Inputs 8 Number of addressable nodes 4 Number of addressable nodes 4 Number of addressable nodes 4 Standard Addressing 239 2179 Standard Addressing 239 2162 Available Outputs 16 Available Outputs 16 Available Inputs 12 Available I...

Page 5: ... numatics com fieldbus 4 I O Mapping Example Example Assumed Settings Single Z Boards are used with single solenoid valves Double Z Boards are used with double solenoid valves Node is configured to use addresses 28 29 30 and 31 on an AS i network 16 Outputs and 12 Inputs total Node uses standard addressing ...

Page 6: ...Valve Coil No 9 Valve Coil No 10 Valve Coil No 11 Valve Coil No 12 31 Valve Coil No 13 Valve Coil No 14 Valve Coil No 15 Valve Coil No 16 Input Table Node Address Input Bit 28 Input No 1 Input No 2 Input No 3 Input No 4 29 Input No 1 Input No 2 Input No 3 Input No 4 30 Input No 1 Input No 2 Input No 3 Input No 4 31 Not Available on this Module If double z boards are used to power a single solenoid...

Page 7: ... 7 3835051 TDG22ASQS1 4 9 06 Subject to change without notice www numatics com fieldbus 5 Input Pin Out AS i Input 8mm M8 connector Pin Out Chart Pin No Function Description 1 24 VDC Input Power 3 0 VDC Input Common 4 Input 1 Input Signal PNP ...

Page 8: ... currently unable to connect to I O OFF There is currently no power applied to the power connector on the second addressable circuit board PWRext 2 Green ON There is currently power applied to the power connector on the second addressable circuit board OFF There is currently no power applied to the bus connector on the second addressable circuit board PWRbus 2 Green ON There is currently power app...

Page 9: ...er Rating Maximum system current capability is 1 Amp when powering outputs through the network cable Voltage Tolerance Current Power Solenoid Valve Coil 2005 Each 24VDC 10 15 0 042 A 1 00 Watts Solenoid Valve Coil 2012 Each 24VDC 10 15 0 105 A 2 50 Watts Solenoid Valve Coil 2035 Each 24VDC 10 15 0 105 A 2 50 Watts Solenoid Valve Coil ISO SPA Each 24VDC 10 15 0 160 A 4 00 Watts Discrete Input Statu...

Page 10: ...sioning an AS i network all slave node device addresses must be set on the connected nodes This network address is stored in the non volatile flash memory within the node Setting the node address can be achieved in the following ways 1 Via the network connection using an AS i master and the appropriate software that allows Change_Operating_Address function However care should be taken that there a...

Page 11: ... manuals local distributors and other Numatics Inc products and support issues can be found on the Numatics Inc s WEB site at www numatics com Features Description AS i Spec Supported Designed to AS i Specification Revision 2 1 Bus Topology Daisy chained star branch lines or tree structure using flat two wire cabling Description Default Settings Standard Addressing Modules 4 Output Module AS i Add...

Page 12: ... que la configuration de l ensemble de l îlot livré correspond à votre commande distributeurs E S protocole 2 Introduction à la série G2 2 Ci dessous un exemple représentant l ensemble d un îlot de distributeurs de la série 2012 Cette série d îlots à bus de terrain est capable d adresser jusqu à 16 entrées et 16 sorties au total en utilisant 4 adresses AS i séparées Cette configuration inclut 16 s...

Page 13: ...ption Code Carte de sortie d ED à adressage standard 256 836 Carte de sortie d ED à adressage étendu 256 907 Ensemble de couvercle à 0 entrées 205 329 Ensemble de couvercle à 4 entrées 205 330 A déplacement d isolant technique vampire Ensemble de couvercle à 8 entrées 205 331 Schéma des E S du module complet de communication AS i Adressage standard 239 2055 Adressage standard 239 2058 Adressage st...

Page 14: ...ibles 6 Sorties disponibles 6 Sorties disponibles 9 Entrées disponibles 4 Entrées disponibles 8 Entrées disponibles 0 Nombre de nœuds adressables 2 Nombre de nœuds adressables 2 Nombre de nœuds adressables 3 Adressage standard 239 2181 Adressage standard 239 2231 Adressage standard 239 2232 Sorties disponibles 12 Sorties disponibles 12 Sorties disponibles 12 Entrées disponibles 4 Entrées disponibl...

Page 15: ...e étendu 239 2169 Adressage étendu 239 2168 Adressage étendu 239 2167 Sorties disponibles 12 Sorties disponibles 12 Sorties disponibles 12 Entrées disponibles 0 Entrées disponibles 4 Entrées disponibles 8 Nombre de nœuds adressables 4 Nombre de nœuds adressables 4 Nombre de nœuds adressables 4 Adressage standard 239 2179 Adressage standard 239 2162 Sorties disponibles 16 Sorties disponibles 16 Ent...

Page 16: ...Exemple de mapping des E S Exemple Assumed Settings Cartes Z BoardsTM simples utilisées avec les électrodistributeurs simples Cartes Z BoardsTM doubles utilisées avec les électrodistributeurs doubles Le nœud est configuré pour utiliser les adresses 28 29 30 et 31 sur un réseau AS i 16 sorties et 12 entrées au total Le nœud utilise l adressage standard ...

Page 17: ... no 11 Bobine no 12 31 Bobine no 13 Bobine no 14 Bobine no 15 Bobine no 16 Tableau des entrées Adresse du nœud Bit d entrée 28 Entrée no 1 Entrée no 2 Entrée no 3 Entrée no 4 29 Entrée no 1 Entrée no 2 Entrée no 3 Entrée no 4 30 Entrée no 1 Entrée no 2 Entrée no 3 Entrée no 4 31 Pas disponible sur ce module Lors de l utilisation de cartes z board doubles pour l alimentation d un électrodistributeu...

Page 18: ...s réserve de modification sans avis préalable www numatics com fieldbus 5 Affectations des broches des entrées Schéma de connexion du connecteur 8 mm M8 AS i No de broche Fonction Description 1 24VCC Alimentation des entrées 3 0 VCC Commun d entrée 4 Entrée 1 Signal d entrée PNP ...

Page 19: ... ne peut pas se connecter aux E S à présent OFF Le connecteur d alimentation sur la 2e carte électronique adressable n est pas alimenté en tension à présent PWRext 2 Vert ON Le connecteur d alimentation sur la 2e carte électronique adressable est alimenté en tension à présent OFF Le connecteur bus sur la 2e carte électronique adressable n est pas alimenté en tension à présent PWRbus 2 Vert ON Le c...

Page 20: ...n réseau Puissance Le courant maxi sur le système est de 1A lors de l alimentation des sorties via le câble réseau Tension Tolérance Courant Puissance Bobine d ED 2005 chaque 24VCC 10 15 0 042 A 1 00 Watts Bobine d ED 2012 chaque 24VCC 10 15 0 105 A 2 50 Watts Bobine d ED 2035 chaque 24VCC 10 15 0 105 A 2 50 Watts Bobine d ED ISO SPA chaque 24VCC 10 15 0 160 A 4 00 Watts LEDs d état des entrées di...

Page 21: ...sage de nœuds AS i Lors de la mise en service d un réseau AS i toutes les adresses des appareils nœud esclave doivent être réglés sur les nœuds connectés Cette adresse de réseau est sauvegardée dans la mémoire flash non volatile du nœud L adresse du nœud peut être réglée des manières suivantes 1 Via la connexion réseau en utilisant un maître AS i et le logiciel approprié qui permet la fonction Cha...

Page 22: ...s distributeurs locaux ainsi que d autres informations sur les produits et le support Numatics Inc se trouvent sur le site web Numatics Inc sous www numatics com Caractéristique Description AS i Spec Supported Spécifications AS i supportées Conçu selon la spécification AS i Révision 2 1 Topologie de bus En série daisy chain en étoile en dérivation ou en structure arborescente via un câble plat à d...

Reviews: