background image

Instruction Manual

D450013T012
August 2016

Type P520L

Type P520L Reamer

Introduction

The Type P520L tapered reamer is calibrated for propane 

vapor by drill size. Refer to the NATIONAL FUEL GAS CODE, 

NFPA 54-2006, Table F.1 (b) and Table F.1 (c) for BTU/hour for 

a specific orifice and gas size. Use Type P520L to enlarge or 

clean out orifices on LP-Gas appliances ranging from drill size 

no. 52 to 30 (0.0635 to 0.125 in.). 
Use the reamer as follows:

The reamer is designed with knurls on the handle for better 

grip. Make sure reamer is held in vertical position while doing 

the following steps.

To enlarge orifices:

1. 

Loosen the reamer by twisting the knurls against the 

slide rule.

2.  Push the slide rule towards the end of the reamer body 

until the cursor points to the desired orifice or drill size.

3. 

Once the cursor is aligned with the desired drill size, 

lock position by twisting the knurl in opposite directions.

4. 

Hold the orifice with one hand and the reamer with 

the other.

5. 

Insert the tip of the reamer into the orifice as far as it 

can go.

6. 

Start reaming until the orifice contacts the end of the 

reamer body.

7. 

Remove the reamer from the orifice.

8. 

Unlock the reamer and retract the slide rule to the fully 

closed position.

9. 

Lock handle.

To check orifice sizes:

1.  Loosen the reamer.
2.  Extend the reamer tip fully.
3. 

Lock the reamer. 

4. 

Insert the reamer tip into the orifice until it sits 

quite snugly. 

5. 

Unlock the reamer and allow the handle to drop and 

contact the tip of the orifice.

6. 

Lock position.

7.  Read the indicated drill size
8.  Remove the reamer and retract the slide rule to the fully 

closed position.

9. 

Lock handle.

CAUTION

Always retract the reamer to the 

fully closed position and tighten the handle 

before placing the reamer into pocket. Failure 

to do so may result in personal injury.

This reamer can also be used on appliance orifices 

where gas other than propane is used. The following 

chart shows the BTU Orifice Capacity by Gas and Orifice 

Sizes. (Tables are from NATIONAL FUEL GAS CODE, 

NFPA 54-2006, 2006 edition.)

Figure 1. 

Type P520L Reamer

hANdLe wITh 

kNURLs

CURsOR

dRILL mARks

sLIde RULe

ReAmeR TIP 

exTeNds AT 

ThIs eNd

mARkINgs

ReAmeR TIP

P2115_1

P2114_1

P2116_1