Step 1: Physical Installation

Step 2: Verify Operation

Step 3: Communication and Configuration

Start

End

CSI 9420 Wireless Vibration Transmitter

Summary of Contents for CSI 9420

Page 1: ...etweb com Quick Installation Guide P N MHM 97409 4 April 2010 CSI 9420 Step 1 Physical Installation Step 2 Verify Operation Step 3 Communication and Configuration Start End CSI 9420 Wireless Vibration Transmitter ...

Page 2: ...T NOTICE The CSI 9420 and all other wireless devices should be installed only after the 1420 Wireless Gateway has been installed and is functioning properly Wireless devices should also be powered up in order of proximity from the 1420 Wireless Gateway beginning with the closest This will result in a simpler and faster network installation IMPORTANT NOTICE Shipping considerations for wireless prod...

Page 3: ...Guide applies to both the 2 4 GHz and 900 MHz Wireless HART versions of the CSI 9420 If you are unsure which version the device is look in the upper right hand corner of the nameplate as illustrated in Figure 1 below Figure 1 Nameplates with radio frequency version highlighted by circles ...

Page 4: ...ilable in a separate Sensor Installation Guide on the CD packaged with this device and at www mhm assetweb com To maintain mechanical isolation of the sensor a Remote Mount configuration is required as illustrated in Figure 2 In this configuration the sensor is mounted separately from the CSI 9420 housing then connected to the CSI 9420 Although not required for all installations it is common to ru...

Page 5: ... straight up or straight down Figure 2 Remote mounting of the CSI 9420 involves mounting the device away from the equipment to be measured upper left connecting a sensor or accelerometers to the equipment and the CSI 9420 upper right and removing the rear cover and power module of the device to connect the sensor wires bottom ...

Page 6: ...nnecting One Sensor with Vibration and Temperature Connecting One Accelerometer Connector labeled 1 Sensor Power Red Wire Connector labeled 2 Sensor Signal White Wire Connector labeled 3 Unused Connector labeled 4 Sensor Common Black Wire Connecting Two Accelerometers Connector labeled 1 Power Both Sensors Two Red Wires Connector labeled 2 Signal Sensor 1 White Wire Connector labeled 3 Signal Sens...

Page 7: ... the Diagnostic DIAG button once and the CSI 9420 will cycle through display of the TAG Device ID Network ID Network Join Status and Device Status screens then make a measurement Pressing the DIAG button causes this information to be displayed even if the LCD is disabled for normal operation NOTE To access the DIAG button remove the front cover of the CSI 9420 The Network join status as displayed ...

Page 8: ...tor with the rev 3 CSI 9420 a rev 3 DD Device Description file is required The rev 3 DD for the CSI 9420 is located on the CD that is shipped with the CSI 9420 375 475 System Software version 3 2 or later is also required Refer to Figure 6 for an illustration of connecting the 375 475 to the CSI 9420 The wired HART connection is located on the terminal block in the rear chamber of the device It is...

Page 9: ...sh rate and the alert thresholds Key sequences for common configuration tasks are shown in Table 6 for the 2 4 GHz Wireless HART version and Table 7 for the 900 MHz version Table 6 CSI 9420 2 4 GHz Fast Key Sequence Function Key Sequence Menu Items Wireless 2 2 2 Manual Setup Network Identifier Join Device to Network Broadcast Rates Power Source Power Save Publish Wireless 2 1 2 Guided Setup Join ...

Page 10: ... network and if it is communicating properly NOTE It may take several minutes for the device to join the network NOTE If the device joins the network and immediately has an alarm present it is likely due to sensor configuration Check the sensor wiring see figure 3 and tables 1 3 and the sensor configuration Function Key Sequence Menu Items Device Information 1 1 8 Tag Date Descriptor Message Distr...

Page 11: ...Quick Installation Guide P N MHM 97409 4 April 2010 CSI 9420 11 Figure 7 1420 Network Settings ...

Page 12: ...ce must first be performed on the 1420 and the CSI 9420 device before the drag and drop operation is performed Once the new device appears under the HART modem tree drag the device over the wireless gateway icon and release it This automatically sets the Network ID and Join Key and causes the device to join the network when it is in range Refer to the AMS Device Manager documentation for additiona...

Page 13: ...mbedded temperature may be used The operational ranges for the sensors are shown in Table 10 Table 10 Sensor ranges The accelerometers require a DC bias The CSI 9420 device provides the necessary bias and measures it to verify correct sensor operation The nominal bias voltage is 2 5 volts If the bias voltage is outside of the 2 3 volt range the device generates a FAILED alert for the associated ac...

Page 14: ...Quick Installation Guide P N MHM 97409 4 April 2010 CSI 9420 14 ...