background image

Part No. F40BP74200002

Form No. BP7420-2

ETL Model No.: CF713

READ AND SAVE THESE INSTRUCTIONS

PRO Series Energy Star
Ceiling Fan Owner's Manual

Net Weight:  

19.0 

Lbs.

Model Numbers:

CF713BS00
CF713ORB00

CF713WW00

Summary of Contents for CF713BS00

Page 1: ...rt No F40BP74200002 Form No BP7420 2 ETL Model No CF713 READ AND SAVE THESE INSTRUCTIONS PRO Series Energy Star Ceiling Fan Owner s Manual Net Weight 19 0 Lbs Model Numbers CF713BS00 CF713ORB00 CF713WW00 ...

Page 2: ...es listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Page 3: ...ck off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan insta...

Page 4: ...lose to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case should the fan blades be lower than seven feet above the floor...

Page 5: ...be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING Installing The Hanger Bracket Installing The Ceiling Cover On The Fan Motor Housing For Close to the Ceiling Mounting 1 Remove and retain three screws from the top of the motor housing Figure 3A 2 Position the rubber gasket supplied in parts bag on the motor housing ...

Page 6: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor Housing 1 Carefully lift the fan assembly up to the hanger bracket Pass the hook on the hanger bracket Figure 8 through one of the screw holes not the slots in the ceiling cover Figure 9 The hook must pass f...

Page 7: ...e rubber grommets are firmly seated on each of the blade flanges Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade Figure 12 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 10 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector s...

Page 8: ...he motor hub by mating the alignment post Figure 12 of the flange with one of the alignment slots in the motor hub Figure 13 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other four blade assemblies Make sure all screws are tightened 5 Attach the switch housing cover with light fitter to the switch housing using the three prev...

Page 9: ... the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 10 Install pendants onto light fixture chain and fan switch chain using couplings provided NOTE It is advisable to periodically check the tightness of the finial IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that ...

Page 10: ...r coupling are loose 1 Tighten both setscrews securely in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure th...

Page 11: ...t authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warran...

Page 12: ...4 Pendant Light 15 Screw M5 x 6 Washer Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket 18 Finial Nut 762892 3 762892 1 762892 6 19 Outer Bowl Cap 762891 3 762891 1 762891 6 20 Fuse 1 25A 125W 763744 763744 763744 Owner s Manual BP7420 2 BP7420 2 BP7420 2 Repair Parts Listing Form No BP7420 2 Part No F40BP74200002 Printed in China 06 10 Air Comfort Products DIVISION OF EMERSON ELECTR...

Reviews: