background image

www.EmersonProcess.com/Bristol 

Product Information Package 

PIP-EXPTIBS

 

Mar., 2007 

 
 

 

               TeleFlow Plus & TeleRTU Plus

 

Expansion Transmitter Interface 
Board Part No. 392951-01-0

 

 

For The Following Bristol Instruction Manuals: 
CI-3530-20B & CI-3530-25B

 

 
 
 
 
 
 

 

Summary of Contents for Bristol 392951-01-0

Page 1: ...ss com Bristol Product Information Package PIP EXPTIBS Mar 2007 TeleFlow Plus TeleRTU Plus Expansion Transmitter Interface Board Part No 392951 01 0 For The Following Bristol Instruction Manuals CI 3530 20B CI 3530 25B ...

Page 2: ...t to Bristol for repairs or evaluation please note the following The party sending such materials is responsible to ensure that the materials returned to Bristol are clean to safe levels as such levels are defined and or determined by applicable federal state and or local law regulations or codes Such party agrees to indemnify Bristol and save Bristol harmless from any liability or damage which Br...

Page 3: ...TEND BEYOND THE DESCRIPTION OF THE FACE HEREOF F No agent of Bristol is authorized to assume any liability for it or to make any written or oral warranties beyond those set forth herein REMEDIES A Buyer s sole remedy for breach of any warranty is limited exclusively to repair or replacement without cost to Buyer of any goods or parts found by Seller to be defective if Buyer notifies Bristol in wri...

Page 4: ...he Bristol Web site www bristolbabcock com and sending it via E Mail to brepair bristolbabcock com A Bristol Repair Dept representative will return E Mail or other requested method with a RA number C Mail Mail the form GBU 13 01 to Bristol Inc Repair Dept 1100 Buckingham Street Watertown CT 06795 A Bristol Repair Dept representative will return call or other requested method with a RA number D Pho...

Page 5: ... a separate sheet if necessary 2 Comm interface used Standalone RS 485 Ethernet Modem PLM 2W or 4W or SNW Other ______________ 3 What is the Firmware revision _____________________ What is the Software version Part III If checking replaced for any question below check an alternate option if replacement is not available A If product is within the warranty time period but is excluded due to Bristol ...

Page 6: ...ull schedule of classes conducted by full time professional instructors Classes are offered throughout the year at three locations Houston Orlando and our Watertown CT headquarters By participating in our training your personnel can learn how to install calibrate configure program and maintain any and all Bristol products and realize the full potential of your system For information or to enroll i...

Page 7: ...es Many Bristol software products incorporate help screens In addition the software typically includes a read me release notes file detailing new features in the product as well as other information which was available too late for inclusion in the manual Contacting Bristol Inc Directly Bristol s world headquarters is located at 1100 Buckingham Street Watertown Connecticut 06795 U S A Our main pho...

Page 8: ...com Telephone Support Non Technical Questions Product Orders etc Questions of a non technical nature product orders literature requests price and delivery information etc should be directed to the nearest sales office listed on the rear cover of this manual or to your Bristol authorized sales representative Please call the main Bristol Inc number 860 945 2200 if you are unsure which office covers ...

Page 9: ... 1 3 JUMPER JP1 2 Section 2 INSTALLATION SERVICE 2 1 REMOVAL REPLACEMENT INSTALLATION OF THE ETIB 3 2 1 1 Removal Replacement of the Expansion Transmitter Interface Board 3 2 1 2 Installation of the Expansion Transmitter Interface Board Option 6 2 2 FIELD WIRING 7 2 2 1 Terminal Connections 7 Section 3 SPECIFICATIONS 3 1 GENERAL SPECIFICATION 9 3 2 ENVIRONMENTAL SPECIFICATIONS 9 SUPPLEMENTS Specia...

Page 10: ...erfaced to a TeleFlow TeleRTU CPU Board via the CPU Board s Expansion Con nector Power from and communication with the host CPU Board is supplied through the Expansion Connector ETIB Boards contain one jumper JP1 for configuration purposes 1 1 1 Transmitter Operation Each Transmitter must be assigned a unique address via the SMARTKIT program as described in Section 4 2 PROGRAM LOADING AND STARTUP ...

Page 11: ...508 Transmitter LED DS2 RTS will be OFF and LED DS1 Carrier Detect CD will be ON 1 3 JUMPER JP1 Jumper JP1 is used to configure the ETIB for operation with one or two 3508 Transmitters If only one 3508 Transmitter is to be connected to the ETIB Jumper JP1 must be installed across JP1 1 and JP1 2 Additionally when only one 3508 Transmitter is to be connected to the ETIB it must be connected to conn...

Page 12: ...2 1 1 Removal Replacement of the Expansion Transmitter Interface Bd An installed ETIB option will contain the following parts 1 Expansion Transmitter Interface Board ETIB with removable Terminal Blocks 2 Three 8 32 x 1 4 SEM Screws 3 Three 4 40 x 15 32 Standoffs Figure 2 Expansion Transmitter Interface Bd Mounted on TeleFlow CPU Board ...

Page 13: ... and 6 below in reverse order installing rather than removing the item in question and then perform step 7 see Figures 4 5 Note Any PC Board is not to be removed under any circumstances unless the TeleFlow TeleRTU has been moved to an ESD safe area see ESDS Manual S14006 The CPU Board should typically only be removed to replace the on board Lithium Battery or Fuse F1 or to install an optional I O ...

Page 14: ...pansion ETIB 5 Remove the two screws that secure the CPU Board s Sliding Mounting Bracket to the Fixed Bracket on the bottom of the Battery Bracket Carefully slide the CPU Board and optional ETIB Board toward the front of the unit and remove harness connections from the Front Panel Switch J12 on TeleFlow CPU J14 on TeleRTU CPU the Display Module J2 on TeleFlow CPU J17 on TeleRTU CPU the Wakeup Swi...

Page 15: ...oard see Section 2 1 1 steps 2 through 5 2 Replace the three screws that secure the CPU Board to the Mounting standoffs with 4 40 x 15 32 Standoffs see Section 2 1 1 Figures 4 5 3 Install the ETIB Board onto the CPU Board in question making sure that the Expansion Connectors properly mate Secure the ETIB Board to the three mounting standoffs with three 8 32 x 1 4 screws 4 Reinstall the CPU Board w...

Page 16: ...d fully to prevent short circuits Allow some slack in the wires when making terminal connections The slack makes the connections more manageable and minimizes mechanical strain on the printed circuit boards and harnesses 2 2 1 Terminal Connections ETIB Boards contain two terminal blocks that field wiring connections to the transmitter s TB1 TB2 are two position Terminal Blocks which connect to the...

Page 17: ...30 20B CONNECTION If no PDB 3530 25B CONNECTION If no PDB TB1 1 XMTR1 3508 3508 3508 TB1 2 XMTR1 3508 3508 3508 TB2 1 XMTR2 3508 3508 3508 TB2 2 XMTR2 3508 3508 3508 ETIB Boards may be connected to internally powered transmitters Connection to internally powered transmitters powered from ETIB s on board 12V Supply Regulator is illustrated in Figure 7 ...

Page 18: ...t within a shielded enclosure with the TeleFlow 3530 20B or the TeleRTU 3530 25B electronics EMI radiation is insignificant and susceptibility is comparable or superior to associated electronics Transient Susceptibility Field connected circuits are designed to meet the requirements of ANSI IEEEC37 90 1998 Formerly IEEE 472 for surge withstand capability 3 2 ENVIRONMENTAL SPECIFICATIONS Operating T...

Page 19: ...s document always follow the instructions in this document 2 Wiring must be performed in accordance with Class I Division 2 wiring methods as defined in Article 501 4 b of the National Electrical Code NFPA 70 for installations within the United States or as specified in Section 18 152 of the Canadian Electrical Code for installation in Canada 3 WARNING EXPLOSION HAZARD Substitution of components m...

Page 20: ...of Emerson Electric Co Other trademarks or copyrighted products mentioned in this document are for information only and belong to their respective companies or trademark holders Copyright c 2007 Bristol Inc 1100 Buckingham St Watertown CT 06795 No part of this manual may be reproduced in any form without the express written permission of Bristol Inc Emerson Process Management Bristol Inc 1100 Buck...

Page 21: ...ks that allow you to go to a specific manual s Table of Content T O C return to document PIP EXPTIBS Table of Content or return to the first page of the Main Menu Links are provided by selecting the appropriate Link Text Box ...

Reviews: