background image

Dell Storage Center

SC280 Enclosure
Getting Started Guide

Regulatory Model: SP-2584, E11J

Summary of Contents for Compellent SC280

Page 1: ...Dell Storage Center SC280 Enclosure Getting Started Guide Regulatory Model SP 2584 E11J ...

Page 2: ...the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2015 Dell Inc All rights reserved This product is protected by U S and international copyright and intellectual property laws Dell and the Dell logo are trademarks of Dell Inc in the United States and or other jurisdictions All other marks and names mentioned herein may be trademarks of their...

Page 3: ...System 5 Installation Safety Precautions 5 Installation Overview 5 Connecting the Power Cables 7 Securing the Power Cables 8 Location of Power Switches 8 3 Other Information You May Need 9 4 NOM Information Mexico Only 10 5 Technical Specifications 11 Contents Contents 3 ...

Page 4: ...y the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Safety Warnings A fully configured SC280 expansion enclosure weighs up to 131 kg 288 lb An unpopulated expansion enclosure weig...

Page 5: ...event damage from electrostatic discharge When handling the storage system hardware you should use an electrostatic wrist guard not included or a similar form of protection The storage system chassis must be mounted in a rack the following safety requirements must be considered when doing so The rack construction must be capable of supporting the total weight of the installed chassis and the desig...

Page 6: ...dy to push the drawer toward the chassis until the locks disengage 5 Insert each disk drive in carrier DDIC into the enclosure one at a time Protect the drive from static discharge Handle DDICs by the edges of the frame CAUTION If the enclosure system operates for too long depending on altitude with drive drawers open the enclosure can overheat causing power failure and data loss Such use may inva...

Page 7: ...the OFF position before connecting the power cables Figure 2 Connecting the power cables CAUTION Be careful when closing the rear rack door to ensure that power cords have adequate space as some racks might not be sufficiently deep Installation and Configuration 7 ...

Page 8: ...e other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply UPS or a power distribution unit PDU Location of Power Switches Figure 4 Power switches NOTE Do not power up the enclosure until all Storage Center components are racked and cabled 8 Installation and Configuration ...

Page 9: ...nt or as a separate document The rack documentation included with your rack solution describes how to install your system into a rack The Storage Center Deployment Guide provides information about cabling hardware components configuring a new Storage Center using the System Manager Setup Wizard and managing a Storage Center in System Administrator 3 Other Information You May Need 9 ...

Page 10: ...in compliance with the requirements of the official Mexican standards NOM Importer Dell Inc de México S A de C V Paseo de la Reforma 2620 11 Piso Col Lomas Atlas 11950 México D F Model number SP 2584 E11J Supply voltage 200 240 V CA Frequency 50 60 Hz Current consumption 16 A 4 10 NOM Information Mexico Only ...

Page 11: ...f Independent Disks RAID Controller Dell Compellent SC8000 Management RAID management using Storage Center System Manager version 6 4 1 or later Back Plane Board Connectors 84 SAS hard drive connectors Two sets of SBB connectors Five cooling fan module connectors Two power supply connectors Back Panel Connectors per SBB SAS connectors Asymmetric SAS Cabling for connection to the controller and for...

Page 12: ...hree SAS ports and two for the module status Cooling module One single color LED indicator for module status One single color LED indicator for battery fault status not currently used One single color LED indicator for fan fault status Power Supply Unit PSU One single color LED indicator for PSU fault status One single color LED indicator for AC power fault status One single color LED indicator fo...

Page 13: ...40 to 158 F with a maximum temperature gradation of 20 C per hour Relative humidity Operating 20 to 80 noncondensing with a maximum humidity gradation of 10 per hour Storage 5 to 100 noncondensing Maximum vibration Operating 0 21 g at 5 500 Hz for 15 min Storage 1 04 g at 2 200 Hz for 15 min Maximum shock Operating Half sine shock 5 g 5 with a pulse duration of 10 ms 10 in operational orientations...

Reviews: