background image

  Building Networks for People

 

DVS-104 User Manual v1.00 

 
 
 
 
 
 

D-Link Video Server 

 

DVS-104 

User Manual 

 
 
 

 

 

 
 
 

ver.1.00 

20040507

 

Summary of Contents for DVS-104

Page 1: ...Building Networks for People DVS 104 User Manual v1 00 D Link Video Server DVS 104 User Manual ver 1 00 20040507 ...

Page 2: ...deo Server has been designed for various environments and can be used to build various applications for general security or demonstration purposes For standard applications find the appropriate section in the Chapter How to Use for your application and follow the steps to setup the system To make best use of Video Server read Chapter Advanced Functions to get creative ideas and review Chapter Syst...

Page 3: ...How to Use 29 Authentication 29 Installing Plug in 30 Main Page 31 System Configuration 34 Introduction 34 Setup Wizard 35 Application Wizard 35 Definitions of Configuration 36 Advanced Functions 49 Capture Up to date Still Images 49 Get Continuous Images 50 Video Embedded in Customers Homepage 51 Download Event triggered Snapshots 52 Uploading Snapshots Periodically 53 Customize Graphics in Homep...

Page 4: ... Maintenance 61 Configure System via FTP 62 Telnet Commands 70 Appendix 72 A Troubleshooting 72 B Frequently Asked Questions 75 C Upgrade System Firmware 79 D URL Commands of Video Server 80 E Settings of Supported PTZ Cameras 95 F Camera Control Cable 96 G Time Zone Table 97 H Technical specifications 100 ...

Page 5: ...DVS 104 User Manual v1 00 4 Package Contents If any of the following items are missing please contact your reseller Video Server DVS 104 Power adapter Two I O terminal connectors Camera control cable Null modem cable Utility CD ROM ...

Page 6: ...Building Networks for People DVS 104 User Manual v1 00 ...

Page 7: ...tem operation Industrial real time operating system prevents from malicious hackers and virus that threat Windows or Linux systems The on board watchdog eternally monitors the system operations for dead proof Easy Web access via standard browser You don t have to install any software to access Video Server The embedded Web server makes users can access Video Server anywhere over Internet with any ...

Page 8: ...otally free to use Users can easily utilize the existing PC to be a digital video recorder Schedule or one click recording keep every important moment in your local hard disk reliable motion detection and instant warning make you sharp for every conditions Quick and simple search and playback let you easily find the moment you want to inspect more carefully and output to AVI files for another copy...

Page 9: ... LED s will turn off for a while and then follows the pattern below If any module fails refer to the Appendix A for the error pattern and follow the trouble shooting procedures If the system still cannot operate normally please contact your reseller for technical service Network Interface Condition LED1 Heartbeat LED2 Status before IP installed OFF OFF after IP installed Blink OFF Ethernet during ...

Page 10: ...he next paragraph for correct settings DIP switches 1 to 4 There are four DIP switches numbered from 1 to 4 in the front panel regarding of each video input They are used to enable the 75 ohm resistance of video impedance They should be kept ON if there is only one camera connected to each video input If users want to connect another device such as VCR or multiplexer to the video output the switch...

Page 11: ...minal block COM2 port This RS232 serial port can connect with a modem or the included null modem cable to utilize dial up network when Ethernet is not available If Video Server operates with an Ethernet interface the administrator may use this port to control another PTZ cameras attached to this serial port General I O terminal block Video Server provides a very flexible general I O interface to c...

Page 12: ...nsor input 2 Ground 17 Opto isolated sensor input 3 Max 50mA 12V DC 18 Opto isolated sensor input 3 Ground 19 Opto isolated sensor input 4 Max 50mA 12V DC 20 Opto isolated sensor input 4 Ground Power source Pair of pin 11 12 of AC or DC input is a replacement with the power adapter in case the range cannot meet the requirement The voltage of the power source can be AC or DC and should fall in the ...

Page 13: ...al devices When the system starts up COMMON of both relay switches will be short with NC A simple diagram of example is shown below Power adapter Plug the power jack of the included power adapter to Video Server Connecting the power adapter should be the last operation while physically installing Video Server Administrators may feed an external power source through pin 11 and pin 12 of the general...

Page 14: ...h to achieve the best performance while dial up network with modem is more common in current Internet applications Refer to the related installation section for your network environment If both interfaces are available Ethernet is recommended and will be chosen as the first priority if Ethernet cable and modem are concurrently attached Managing to install in the other interface will automatically ...

Page 15: ...Manual v1 00 13 Ethernet Environment Hardware installation Before installing multiple Video Server s at the well chosen locations the administrator should memorize the serial numbers on the packages respectively for future use Cable connection ...

Page 16: ... sure all cables are correctly and firmly connected Before turning on Video Server remember to run Installer program on PC or notebook in the same network first As long as the Reset network at next boot option in network Web page is enabled the Installer program is needed to install Video Server Turn on cameras sensors alarm devices and then attach power adaptor of Video Server to the electric pow...

Page 17: ...y detecting the network environment If there is DHCP service over the network the Installer program will catch the given information then display the serial number and given IP address for each Video Server as the figure above To install the IP address follow the steps 1 Click on the entry with the serial number you want to install If the Assigned field of the entry is labeled Yes that means the V...

Page 18: ...strators should ask the network supervisor for a vacant IP address While Use this IP whenever system boots is checked a dialog window may pop out to ask for Server FTP Port and Root Password because they are already changed by administrators to other than default settings If the original settings are lost restore default settings and run software installation again Once the installation is complet...

Page 19: ...name table The Ethernet address is identical to the serial number of Video Server and should be typed in the appropriate format like uu vv ww xx yy zz or uu vv ww xx yy zz which depends on the operating system Once the name entity is added type ping assigned IP address to invite the new Video Server If it replies that means Video Server has accepted the assigned IP address and is ready for access ...

Page 20: ...wenty user profiles Each user is able to access Video Server under the given privilege except for system configuration The twenty user profiles are also maintained by the administrator The highest level is ROOT mode that only opens to administrators for initial setup system configuration user administration and software upgrade The user name of the administrator is internally assigned to root Comp...

Page 21: ...em configuration Then both LED s under the power LED will turn on until the dial up connection over null modem is established Installations of both null modem and modem are introduced as follows The null modem mode can be used for point to point connection in local environment the modem mode also applies to TA in ISDN network Though the baud rate can be setup to 115200 bit per second the actual da...

Page 22: ...ithout Ethernet administrators can use the included null modem cable to connect to Video Server directly and access point to point After necessary information is entered and saved turn off Video Server and remove the null modem cable Follow the installation of modem mode in next paragraph to connect to Internet Note Video Server will not really reset system where it is used to in null modem mode M...

Page 23: ...nnection to provide services Before installation make sure the necessary dialing information is correctly setup via Ethernet or null modem connection Power on Make sure all cables are correctly and firmly connected Turn on cameras sensors alarm devices and then finally attach the power adaptor of Video Server to the electric power outlet Since most automatic detections of hardware perform when the...

Page 24: ...ell configure each field for dialing information Refer to the COM2 section in Definition of Configuration for detailed description Via null modem Install a new modem 1 Open the control panel and double click the modems icon 2 Check Don t detect my modem item and click on to install a new modem 3 From Standard Modem Type choose the Standard 33600 bps Modem and click on ...

Page 25: ...ull modem cable is attached to and click on The null modem is now ready for use If no Dial Up adapter exists in the system Windows may automatically prompt to install Press to continue If it does not start automatically double click the network icon in control panel to install Microsoft dial up adapter ...

Page 26: ...lder in Windows to build a new connection 2 Select the device as the newly installed standard 33600 bps modem and click on 3 Just enter arbitrary digits as phone number and click on The phone number here is not important 4 After clicking on this new connection will display in the Dial up Networking folder and will be used for null modem connections ...

Page 27: ...n for entering properties 6 In the first General page clear Use area code and Dialing Properties option and click on 7 Select 115200 as the speed and click on 8 On the second page only check Enable software compression and TCP IP while leaving others blank Keep other settings as default values and click on ...

Page 28: ...d and click on Notice that the letters in the MAC address should be capital form For example type A instead of a After some negotiation prompts a connection status window will show the speed is 115200 bps After connection is established successfully go to the next section First access to Video Server If an error message indicates a hardware error while connecting for the first time especially in M...

Page 29: ...ration immediately After changing the password the browser will display the authentication window again to confirm the new password Manage user privilege Administrators can add up to twenty user profiles in the Security option While Video Server accepts dial in connection and acts as a server the user name and password used in dialing are the same as what is stored in the user database managed for...

Page 30: ...of Video Server After connecting successfully start the Web browser and connect to http 200 1 1 1 In this case Video Server runs as a dial up server and assigns the IP address of 200 1 1 100 to the PC at the other end While seeing the authentication message window type root as user name and the MAC address of Video Server as the initial password The point to point connection allows users connectin...

Page 31: ... the labels under the body of Video Server and the top side of the carton The primary users will be allowed to enter as soon as the administrator finishes adding user profiles Upon successful authentication the main page will be displayed For demonstration purpose enter the Demo Web page of configuration to activate the demo account and choose permitted services Once the demo account is setup any ...

Page 32: ...eb browser is Internet Explorer in Windows users will be asked to install a new plug in that is provided by Video Server This plug in has been registered for certificate and is used to display motioned pictures in the Internet Explorer Users may click on to install the plug in If the web browser does not allow the user to install check the security option to lower security levels or contact networ...

Page 33: ... page of Video Server The first figure below is graphic mode that has better visual effect and the second one is text mode that will shorten download time The main page may look different depending on the PTZ driver or the privilege of the user Graphic mode Text mode is default if any image button is not available ...

Page 34: ...he picture has the slowest refresh rate but the best image quality Video size selection It allows users to adjust the image size with consideration of bandwidth and image resolution Five options are available including Half Half 2 Standard Standard 2 and Double Half 2 consumes the same bandwidth as Half but has the same size with Standard Of course the visual effect is worse than Standard Standard...

Page 35: ...a to the center position if the camera supports this command Besides the near and far control in focus an AUTO button is provided for setting auto focus mode To move the motorized camera more precisely speed control of pan and tilt allows users to fine tune the aiming position Users also can directly click on any point in the image to force the motorized camera to focus on it Users can pull down t...

Page 36: ...n the Chapter Advanced Usage for reference Video Server also supports FTP to modify the system configuration file CONFIG INI for technical usage The details are described in the Chapter Advanced Usage Since it is a networking video server administrators should run Setup wizard or well configure Security Network and Video at least To support external serial port devices configure COM1 and COM2 and ...

Page 37: ...main applications including surveillance system and web attraction by means of Video Server The former one will utilize the built in motion detection and external sensors to integrate with the existing e mail or FTP server or external alarms to constitute a security system It also possesses the weekly schedule for timed monitoring The later one will customize the main page to your personal style a...

Page 38: ...ual is to set the date and time manually by entering new values Notice the format in the related field while typing The third Automatic is to make Video Server automatically synchronize with timeservers over the Internet every month It may fail if the assigned NTP server cannot be reached or Video Server is within a local network Leaving the NTP server blank will let Video Server connect to defaul...

Page 39: ...ivilege If the permitted rights of some user has to be changed pull down the user list to find the user name and press A new window will pop out for administrators to change password and choose different privilege Delete existing users To delete a user pull down the user list to find the user name to be deleted and press A message window will pop up for confirmation Enable snapshot mode for more u...

Page 40: ...iguration may include IP address Subnet mask Default router Primary DNS server and Secondary DNS server After changing network settings be sure to leave Reset network at next boot blank to skip next installation when the system restarts Otherwise those network settings will be erased at the next start Bandwidth utilization limit Each Video Server can be limited in bandwidth utilization by administ...

Page 41: ...connection from the remote FTP server you may be able to connect to the FTP server but unable to put any file due to data channel connection failure Check Primary FTP passive mode for passive transfer solution Another set of Secondary server settings is also provided for backup connection In either e mail or FTP the primary server information should be entered first If the primary server is not se...

Page 42: ...t to Video Server To customize for different camera administrators can adjust Brightness Contrast Hue and Saturation for video compensation of each channel While adjusting administrators can click on to check prior to the setting in memory If the adjustment is not good administrators can click on to restore the original settings without change To facilitate the settings of four video channels admi...

Page 43: ...erver ignore small variations in images While the motion amplitude of some object in the monitored screen is over the settings a white M in red background will indicate at the upper right corner of the window Motion detection is provided as reference because it is very environment dependent Especially working by the very sensitive settings some triggered events may be considered as false alarms th...

Page 44: ...nction for details COM port configuration After saving the driver type the COM port configuration will show up for entering the correct settings that depends on the camera type Refer to the Appendix Settings for Supported PTZ Cameras for default settings of supported PTZ camera including baud rate data bits stop bit and parity bit Custom commands Video Server provides five more custom commands oth...

Page 45: ...p with external sensors and alarms for property security dial out is needed to send some snapshot attached e mails when the preset conditions are triggered In such applications also remember to choose Network option to enter mail server address and recipient s e mail address If Dialout allowed is not checked Video Server will not send out any snapshots when events occur and the settings except for...

Page 46: ... settings For those installations that may switch the network interface between Ethernet and PPP administrators should notice that the settings of FTP or SMTP servers might be different from what are in an Ethernet environment If the network interface is changed administrators may need to configure them in advance Video Server will try the second ISP as a backup when the first ISP fails and exceed...

Page 47: ...Video Server via FTP check the option Enable the external script file to exclude the following settings Otherwise Video Server will operate according to the settings below Event operation Video Server provides general options for two basic applications event operation for security and sequential operation for web attraction In event operation administrators have to setup some conditions to check a...

Page 48: ... details Sequential operation With this feature Video Server can upload snapshots periodically to external server as a live video source The interval can be set from tenth second to several hours The external server must be setup correctly in the Network configuration page Sending method Either event mode or sequential mode can select one method between email and FTP The companied external server ...

Page 49: ...ing a URL The Background graph is similar Default images of the system can be customized but limited by memory size Images from external resources can be larger and more beautiful but will need more time to load If the background is skipped the background color will fill the browser window Administrators also can give the system logo a Logo link to connect to another web site while clicked The Fon...

Page 50: ...ters The whole system parameters will be categorized listed for administrators to check The content is the same as CONFIG INI Factory default It is used to restore the factory default settings This means any changes made before will be lost and the system will be reset to the initial status as shipping out of the factory After confirmation the system will restart and require the software installat...

Page 51: ...e size in file directory means it is captured by request Video channel URL Video 1 http IP of Video Server cgi bin video1 jpg param value Video 2 http IP of Video Server cgi bin video2 jpg param value Video 3 http IP of Video Server cgi bin video3 jpg param value Video 4 http IP of Video Server cgi bin video4 jpg param value Quad of all http IP of Video Server cgi bin videoall jpg param value para...

Page 52: ...all video cgi bin quad jpg param value param value Description cam 1 Video 1 2 Video 2 3 Video 3 4 Video 4 quality 1 Medium 2 Standard 3 Good 4 Detailed 5 Excellent size 1 Half 2 Standard 3 Double 4 Half x 2 5 Standard x 2 param value Description quality 1 Medium 2 Standard 3 Good 4 Detailed 5 Excellent size 1 Half 2 Standard fast 3 Standard clear 4 Half x 2 ...

Page 53: ...ge title head body h2 Video Server Sample Page h2 script language JavaScript if navigator appName Microsoft Internet Explorer navigator platform MacPPC document write OBJECT ID MjpegControl WIDTH 352 HEIGHT 240 document write CLASSID CLSID EAA105FE 7BBD 4196 8B96 D46743894195 document write CODEBASE http username password 192 168 0 201 plugin mjpegcontrol cab version 1 0 0 4 document write PARAM N...

Page 54: ... They can also be browsed from the application page in system configuration Get triggered snapshots via URL cgi bin snapshot jpg file value Video channel Snapshot stage Video 1 Video 2 Video 3 Video 4 snapshot before event pre1 pre2 pre3 pre4 snapshot upon event trg1 trg2 trg3 trg4 snapshot after event pos1 pos2 pos3 pos4 Get triggered snapshots via FTP File name Pre alarm Upon alarm Post alarm Vi...

Page 55: ...iles are intended for quick updates it is better to skip date and time suffix The file name will then be video1 jpg video2 jpg video3 jpg and video4 jpg for four channels If the snapshots are used for occasional monitoring suffix with date and time can help administrators classify them easily Send snapshots to external SMTP email server Comparing to the FTP method email will induce more delay But ...

Page 56: ...tomize preferred image under the size limit and put to the specific name via FTP Administrators can download the original images before upload for backup Usage via FTP is illustrated as below Object File name Maximal size Logo logo gif Logo and background share 8000 bytes Background back gif Logo and background share 8000 bytes Link icon btn_text gif 2000 bytes Camera 1 button btn_cam1 gif 5000 by...

Page 57: ...Building Networks for People DVS 104 User Manual v1 00 55 ...

Page 58: ... s privilege to upload the script file 4 Enter the Application page in system configuration to define the time period in weekly schedule If it is supposed to run any time keep the original settings but check the option All the time except for the above schedule 5 Check the option Enable the external script file to exclude the following settings to activate the command script Command format Event O...

Page 59: ...number 1 2 Digital output state C NC O NO V set video channel to go to preset location P set preset location number to go to preset location W send warning to server IP server IP Port server port Message texts to be sent to the server U upload snapshots Method F is by FTP M is by e mail S take snapshot on channels N define the format of the filename end of line The filename format is c channel num...

Page 60: ...conds B C D W 192 168 0 1 6000 no signal If there is no signal on channel 2 or 3 or 4 a message no signal will be sent to port 6000 of 192 168 0 1 once 2H V1P15 When sensor input 2 is high drive the camera mapped to video 1 to go to preset location 15 M34 UF S1234 N video c a y M d h m s If any motion is detected on channel 3 or 4 upload snapshots taken on channel 1 2 3 and 4 If an event triggered...

Page 61: ...ed camera in PTZ direction cgi bin control cgi param value Recall camera position cgi bin recall cgi cam n recall position n video channel from 1 to 4 position the text string of a location that is preset in system configuration Refer to Camera preset configuration URL for preset function param value Description cam 1 Video 1 2 Video 2 3 Video 3 4 Video 4 move up Tilt up down Tilt down left Pan le...

Page 62: ...ary code to send out Send command to device attached to COM1 cgi bin senddata cgi com 1 data 123456 ABCDEF flush yes wait 1000 read 6 This hyperlink will inform Video Server to send out binary format commands to COM1 with 0x12 0x34 0x56 followed by 0xAB 0xCD 0xEF Each comma separates the commands by 200 milliseconds flush yes means the receive data buffer of COM port must be cleared before read Th...

Page 63: ...wnload the system log file SYSTEM LOG via FTP To log into the FTP daemon enter root as the user name and the same administrator s password used in Web access Restart System via URL cgi bin reset cgi Restart Video Server without warning Restore Factory Default Settings via URL cgi bin restore cgi Video Server will automatically restart after restoring factory default configurations ...

Page 64: ...tems related to disable enable should use the keywords YES NO The number zero entry in user name and user password is for administrators i e root Basically Video Server will restart automatically as soon as the file is accepted If administrators want to cancel the reboot procedure set the first item reset system to NO It will take effect once only and always show YES in the download file A sample ...

Page 65: ...NO or YES to enable snapshot mode more guests interval 0 seconds of snapshot interval LAYOUT layout type 1 image mode or 0 for text mode font color 0 black 1 white 2 green 3 maroon 4 1 olive 5 navy 6 purple 7 gray 8 yellow background color 9 lime 10 aqua 11 fuchsia 12 silver 0 13 red 14 blue 15 teal logo type 1 default image or 0 for blank or 2 from URL background type 1 default image or 0 for bla...

Page 66: ... 2 string of maximum 8 characters 3 string of maximum 8 characters 4 string of maximum 8 characters NETWORK install enabled YES reset IP whenever system boots or NO ppp enabled YES obsolete ethernet address 00 02 D1 04 00 11 read only host ip 192 168 0 207 standard IP format subnet mask 255 255 255 0 standard IP format gateway ip 0 0 0 0 standard IP format primary name server 0 0 0 0 standard IP f...

Page 67: ...rs backup ftp init path string of maximum 40 characters backup ftp passive NO or YES http server port 80 or 1024 65535 bandwidth limit 0 or 64000 128000 256000 512000 768000 1000000 1500000 2000000 VIDEO default video 1 or 2 3 4 camera modulation AUTO or MANUAL NTSC or PAL indication only while AUTO video is open 0 YES or NO 1 YES or NO 2 YES or NO 3 YES or NO video mapped to COM port 0 0 1 0 2 0 ...

Page 68: ...or NO for monochrome video quality 0 75 1 75 2 75 3 75 default size 0 2 1 2 2 2 3 2 brightness 0 0 5 5 1 0 5 5 2 0 5 5 3 0 5 5 contrast 0 0 5 5 1 0 5 5 2 0 5 5 3 0 5 5 hue 0 0 5 5 1 0 5 5 2 0 5 5 3 0 5 5 saturation 0 0 5 5 1 0 5 5 2 0 5 5 3 0 5 5 SERIAL1 data bits 0 stop bits 0 parity bits 0 baud rate 0 ccd model 0 uart mode RS232 or RS485 speedlink commands 0 string of maximum 80 characters 1 str...

Page 69: ...g of maximum 80 characters FAR string of maximum 80 characters SERIAL2 data bits 8 stop bits 1 parity bits 0 baud rate 0 ccd model 0 uart mode RS232 speedlink commands 0 string of maximum 80 characters 1 string of maximum 80 characters 2 string of maximum 80 characters 3 string of maximum 80 characters 4 string of maximum 80 characters custom ccd commands HOME string of maximum 80 characters UP st...

Page 70: ...eries snapshot channel enabled 0 NO or YES 1 NO or YES 2 NO or YES 3 NO or YES application mode 0 visual alert NO or YES upload method 0 file with time suffix YES or NO tenth seconds to snapshot after event 5 snapshots taken after event 1 percentage of object size over screen 0 10 1 99 1 10 1 99 2 10 1 99 3 10 1 99 percentage of sensitivity 0 95 1 99 1 95 1 99 2 95 1 99 3 95 1 99 seconds to snapsh...

Page 71: ...Building Networks for People DVS 104 User Manual v1 00 69 0 NO or YES 1 NO or YES 2 NO or YES 3 NO or YES video is open 0 NO or YES 1 NO or YES 2 NO or YES 3 NO or YES ...

Page 72: ...e Video Server to start dumping the detailed debugging information while the system is running This is useful to examine if any error has occurred when the system operates abnormally The stored information will be cleared automatically after the dump Video Server will continue to dump new messages unless the connection is broken If Telnet is not connected any messages will be stored until administ...

Page 73: ...se graph will clear all images used on the homepage If no new images are uploaded the system will switch to text mode and use default images instead Skip installation at next boot Typing lock will inform Video Server to fix current network settings It need not wait for installation during the next boot Reset network for new settings Typing unlock will make Video Server give up current settings and...

Page 74: ...oubleshooting LED1 ON and LED2 ON Ethernet network 1 Check the LINK LED of the attached port on the Ethernet switch or hub If it is dim the Ethernet cable may be loose or cross over 2 If the cable is OK the Ethernet controller is broken Ask your reseller for technical service LED1 ON and LED2 OFF Ethernet network The PCI interface cannot work Ask your reseller for technical service LED1 OFF and LE...

Page 75: ...Building Networks for People DVS 104 User Manual v1 00 73 or modem interface your reseller for technical service ...

Page 76: ...and attaching it again RESTORE When the system seems to respond or operate slowly after changing some settings and administrators hardly enter the configuration to change back the original settings administrators can perform the restore procedure It is as same as the factory default link on the configuration page To restore the factory default settings click on the RESET button once and then press...

Page 77: ...access to Video Server needs authentication If you are not a permitted user you may view the images or control the camera as long as the demo account is opened The demo account user may use username as demo without any password to access limited features If you are one of the managed users you have to ask the administrators for the password If you are the administrator there is no way to recover t...

Page 78: ... time of my PC or notebook A The timestamp is based on the system time of Video Server It is maintained by a real time clock inside and automatically synchronizes with the time server if Video Server is connected to the Internet and the function is enabled Differences of several hours may result from the time zone setting Q Why does the image not refresh regularly A In a modem environment it is be...

Page 79: ...ublic number You can check system log to examine any abnormal activities and trace the origins Q I have a PTZ camera that is not on the supported list How can I control it A Video Server provides a custom camera command interface to control the cameras not supported The details are described in the manual Be sure the COM port settings are applied to the camera specification The camera control cabl...

Page 80: ...tions in the application A When Video Server is triggered by events snapshots will take more time to write into FLASH If the events occur too often the system will always be busy with storing images That will make users feel like the system responding too slowly If it is in sequential mode the uploading speed depends on the network utilization server performance how many channels are monitored and...

Page 81: ... The file size is near 1 5 mega bytes It will take approximately 2 seconds in a local network 2 minutes by null modem connection or 6 minutes by modem but still subject to user s network 5 After upload is complete close the connection 6 If the received FLASH BIN is checked without error Video Server will update the software in Flash memory and restart automatically When Video Server starts writing...

Page 82: ...y Some pages like image quality setting and preset setting are opened in new windows for preview These URLs can be accessed only by administrators Homepage name Referenced URL configuration page setup config html system option setup system html security option setup security html network option setup network html video option setup video html image quality option setup image html camera control 1 ...

Page 83: ...her page To change the logo or the background images referenced by the URL refer to the homepage layout section in configuration Resource name Referenced URL system logo image logo gif background image back gif button image for camera 1 btn_cam1 gif button image for camera 2 btn_cam2 gif button image for camera 3 btn_cam3 gif button image for camera 4 btn_cam4 gif button image for quad screen btn_...

Page 84: ...r to synchronize method manu directly adjust date and time date yy mm dd year month and date separated by slash time hh mm ss hour minute and second separated by colon ntp domain name or IP address NTP server zone GMT n 00 time zone n ranged from 0 to 12 Security configuration URL URL cgi bin security cgi NAME VALUE DESCRIPTION rootpass text string shorter than 15 characters change root password u...

Page 85: ...ss subnet IP address subnet mask router IP address default gateway domain text string shorter than 40 characters domain name of Video Server dns1 IP address primary DNS server dns2 IP address secondary DNS server smtp1 domain name or IP address primary SMTP server mailto1 text string shorter than 80 characters mail recipient address smtp2 domain name or IP address secondary SMTP server mailto2 tex...

Page 86: ...cond use only 64Kbps of bandwidth 128Kbits second use only 128Kbps of bandwidth 256Kbits second use only 256Kbps of bandwidth 512Kbits second use only 512Kbps of bandwidth 768Kbits second use only 768Kbps of bandwidth 1Mbits second use only 1Mbps of bandwidth 1 5Mbits second use only 1 5Mbps of bandwidth limit 2Mbits second use only 2Mbps of bandwidth Video configuration URL URL cgi bin video cgi ...

Page 87: ...olution Standard lower resolution Good normal setting Detailed higher resolution quality Excellent highest resolution Half set size to half Standard set size to standard Double set size to double Half x 2 set size to half x 2 size Standard x 2 set size to standard x 2 brightness 5 5 adjust brightness of image contrast 5 5 adjust contrast of image hue 5 5 adjust hue of image saturation 5 5 adjust s...

Page 88: ...i NAME VALUE DESCRIPTION RS232 switch COM1 to RS232 interface other than RS232 switch COM1 to RS485 generic accept generic CGI commands detect none no drivers Sony VISCA Canon VCC1 Canon VCC3 Canon VCC4 DynaDome SmartDOME Pelco D protocol Lilin PIH 7x00 Ernitec driver Custom Camera third party PTZ camera ...

Page 89: ...ke modem dial in tone method Pulse ATDP make modem dial in pulse reatt integer redial attempts discon integer minutes delay before disconnection init text string shorter than 40 characters command to initialize modem phone1 text string shorter than 40 characters phone number of primary ISP user1 text string shorter than 40 characters user name for primary ISP pass1 text string shorter than 40 char...

Page 90: ...m12 text string shorter than 80 characters custom command 2 of COM1 com13 text string shorter than 80 characters custom command 3 of COM1 com14 text string shorter than 80 characters custom command 4 of COM1 com15 text string shorter than 80 characters custom command 5 of COM1 str21 text string shorter than 8 characters button name of custom command 1 of COM2 str22 text string shorter than 8 chara...

Page 91: ...f COM2 com25 text string shorter than 80 characters custom command 5 of COM2 Camera preset configuration URL URL cgi bin preset cgi NAME VALUE DESCRIPTION com 1 2 Com port number cam 1 4 Video channel number fixed fixed camera camtype cammap PTZ camera id integer camera id addpos text string shorter than 40 characters add preset position delpos existing position name delete preset position ...

Page 92: ...d string of COM1 right1 text string shorter than 80 characters pan right command string of COM1 home1 text string shorter than 80 characters home command string of COM1 tele1 text string shorter than 80 characters zoom in command string of COM1 wide1 text string shorter than 80 characters zoom out command string of COM1 baud2 integer set baud rate of COM2 data2 integer set data bits of COM2 1 set ...

Page 93: ...thu not required set Thursday in weekly schedule fri not required set Friday in weekly schedule sat not required set Saturday in weekly schedule sbegin hh mm ss time to start in weekly schedule send hh mm ss time to stop in weekly schedule inv not required set inverse mode in weekly schedule enfile not required enable script file emode not required event operation showalert not required show alert...

Page 94: ...eventch3 not required take snapshots on ch3 while event happen eventch4 not required take snapshots on ch4 while event happen dura integer snapshots taken after event inter integer tenth seconds interval after the event mdmode not required enable motion detection emode should set smode not required sequential mode application sinter integer tenth seconds interval for sequential mode mail upload sn...

Page 95: ...ired enable demo account camctr1 not required allow demo user to control PTZ camera on video 1 camctr2 not required allow demo user to control PTZ camera on video 2 camctr3 not required allow demo user to control PTZ camera on video 3 camctr4 not required allow demo user to control PTZ camera on video 4 view1 not required allow demo user to watch channel 1 view2 not required allow demo user to wat...

Page 96: ...ef use default background cusback url use image from URL backurl text string shorter than 80 characters URL of image for background fcolor 0 15 color index for font bcolor 0 15 color index for background image display homepage in image mode dismode text display homepage in text mode strl text string shorter than 40 characters text for channel 1 in text mode str2 text string shorter than 40 charact...

Page 97: ...er than the default settings check the correct default settings for the attached camera Camera model Baud rate Data bits Stop bit Parity bit Sony VISCA 9600 8 1 None Canon VC C1 9600 8 2 None Canon VC C3 9600 8 2 None Canon VC C4 9600 8 1 None Pelco D protocol 2400 8 1 None Dynacolor dome 9600 8 1 None Ernitec 9600 8 1 None Lilin 9600 8 1 None ...

Page 98: ...cluded cable can be used to control motorized cameras of desktop types from Sony and Canon The pin assignment is illustrated in the following chart To control cameras of another brand check the user s manual of the motorized camera if the pin assignment of the control cable is appropriate ...

Page 99: ...S Canada GMT 06 00 Central America GMT 06 00 Central Time US Canada GMT 06 00 Guadalajara Mexico City Monterrey GMT 06 00 Saskatchewan GMT 05 00 Bogota Lima Quito GMT 05 00 Eastern Time US Canada GMT 05 00 Indiana East GMT 04 00 Atlantic Time Canada GMT 04 00 Caracas La Paz GMT 04 00 Santiago GMT 03 30 Newfoundland GMT 03 00 Brasilia GMT 03 00 Buenos Aires Georgetown GMT 03 00 Greenland GMT 02 00 ...

Page 100: ...erevan GMT 04 30 Kabul GMT 05 00 Ekaterinburg GMT 05 00 Islamabad Karachi Tashkent GMT 05 30 Chennai Kolkata Mumbai New Delhi GMT 05 45 Kathmandu GMT 06 00 Almaty Novosibirsk GMT 06 00 Astana Dhaka GMT 06 00 Sri Jayawardenepura GMT 06 30 Rangoon GMT 07 00 Bangkok Hanoi Jakarta GMT 07 00 Krasnoyarsk GMT 08 00 Beijing Chongqing Hongkong Urumqi GMT 08 00 Taipei GMT 08 00 Irkutsk Ulaan Bataar GMT 08 0...

Page 101: ...orks for People DVS 104 User Manual v1 00 99 GMT 10 00 Hobart GMT 10 00 Vladivostok GMT 11 00 Magadan Solomon Is New Caledonia GMT 12 00 Auckland Wellington GMT 12 00 Fiji Kamchatka Marshall Is GMT 13 00 Nuku alofa ...

Page 102: ...uts max 24VDC 1A 125VAC 0 5A LED Indicator System power and status indicators Network link and speed indicators Dimension 216 7mm L 193 7mm W 44 3mm H Weight Net 970g Power Consumption near 7 8W Universal switching power supply included Input 100 240VAC 50 60Hz 0 4A Output 12VDC 1 5A External power supply 6 15VDC min 15W Operating Environment Temperature 0 65 C 32 149 F Humidity 95 RH Alarm Featur...

Page 103: ...d not be new or of an identical make model or part D Link may in its discretion may replace the defective Hardware or any part thereof with any reconditioned product that D Link reasonably determines is substantially equivalent or superior in all material respects to the defective Hardware The Warranty Period shall extend for an additional ninety 90 days after any repaired or replaced Hardware is ...

Page 104: ... written description of the Hardware defect or Software nonconformance in sufficient detail to allow D Link to confirm the same The original product owner must obtain a Return Material Authorization RMA number from the Authorized D Link Service Office and if requested provide written proof of purchase of the product such as a copy of the dated purchase invoice for the product before the warranty s...

Page 105: ...AL INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF GOODWILL WORK STOPPAGE COMPUTER FAILURE OR MALFUNCTION LOSS OF INFORMATION OR DATA CONTAINED IN STORED ON OR INTEGRATED WITH ANY PRODUCT RETURNED TO D LINK FOR WARRANTY SERVICE RESULTING FROM THE USE OF THE PRODUCT RELATING TO WARRANTY SERVICE OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY EVEN IF D LINK HAS BEE...

Page 106: ...w Elektrischen Schlag auslösen 14 Öffnen Sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden 15 Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen a Netzkabel oder Netzstecker sint beschädigt b Flüssigkeit ist in das Gerät eingedrungen c D...

Page 107: ...dvertencia de Marca de la CE Este es un producto de Clase A En un entorno doméstico puede causar interferencias de radio en cuyo case puede requerirse al usuario para que adopte las medidas adecuadas Attention Ceci est un produit de classe A Dans un environnement domestique ce produit pourrait causer des interférences radio auquel cas l utilisateur devrait prendre les mesures adéquates Attenzione ...

Page 108: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer o...

Page 109: ...l Europe D Link Deutschland GmbH Schwalbacher Strasse 74 D 65760 Eschborn Germany TEL 49 6196 77990 FAX 49 6196 7799300 INFO LINE 00800 7250 0000 toll free HELP LINE 00800 7250 4000 toll free REPAIR LINE 00800 7250 8000 E MAIL info dlink de URL www dlink de IBERIA D LINK IBERIA Gran Via de Carlos III 84 3 Edificio Trade 08028 BARCELONA TEL 34 93 4090770 FAX 34 93 4910795 E MAIL info dlinkiberia es...

Page 110: ...0 8731 5555 FAX 44 20 8731 5511 E MAIL info dlink co uk URL www dlink co uk U S A D LINK U S A 17595 Mt Herrmann Street Fountain Valley CA 92708 USA TEL 1 714 885 6000 FAX 1 866 743 4905 INFO LINE 1 877 453 5465 E MAIL tech dlink com support dlink com URL www dlink com ...

Page 111: ...Building Networks for People DVS 104 User Manual v1 00 109 ...

Page 112: ...Building Networks for People DVS 104 User Manual v1 00 110 ...

Page 113: ...Building Networks for People DVS 104 User Manual v1 00 111 ...

Reviews: