DCH-112 Door/ Window Sensor                 

The DCH-112 has door/window sensor function in one, based on  Z-

Wave

TM

 technology.

It is the  Z-Wave

TM

  plus product, it support the security, OTA... Those

newest features of the  Z-Wave

TM

  technology.  Z-Wave

TM

  is a wireless

communication protocol designed for home automation, specifically to

remotely   control   applications   in   residential   and   light   commercial

environments. The technology uses a low-power RF radio embedded or

retrofitted into home electronics devices and systems, such as lighting,

home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Add to/Remove from Z-Wave

TM

 Network

There are  two tamper  keys in the  device, one is in  the back side,

another is in the front side.  Both of them  can add, remove, reset or

association from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, 

make sure the primary controller is in the add mode. And then power 

on the device, just take out the insulation Mylar in the back side of the 

device. The device will auto start the NWI (Network Wide Inclusion) 

mode. And it should be included in 5 seconds. You will see the LED 

light ON one second.

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the inclusion mode.

3. After add successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

1

Summary of Contents for DCH-112

Page 1: ...s The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association...

Page 2: ...ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in ...

Page 3: ...ery 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Door window state report Every 6 hours report once in default It could be changed by setting the configuration NO 11 Illumination level report Every 6 hours report once in default It could be changed by setting the configur...

Page 4: ...also will light ON one second When the event triggered the device will report the messages to the nodes in the group 1 The messages also include the battery level the temperature and the illumination level The user can switch the report by setting the configuration NO 5 bit4 illumination and bit5 temperature and the configuration NO 7 bit6 battery When the event triggered if the environment lumina...

Page 5: ...he device trig please associate with the device into the second group 3 In the accessory pack There are two type of double coated tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let ...

Page 6: ...report after event triggered 1 Disable 0 Enable 0 Bit5 Disable the temperature report after event triggered 1 Disable 0 Enable NO Name Def Vali d A B C Description 0 Bit6 Reserve 0 Bit7 Disable the back key release into test mode 1 Disable 0 Enable 7 Customer Function 4 All Customer function switch using bit control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bi...

Page 7: ...Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte the range is from 0x00 0xFF Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SE...

Page 8: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 9: ...s substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 9 ...