background image

Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide

First Published:

2018-08-14

Last Modified:

2020-02-28

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Summary of Contents for UCS 6400 Series

Page 1: ...t Hardware Installation Guide First Published 2018 08 14 Last Modified 2020 02 28 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Page 2: ... 2018 2020 Cisco Systems Inc All rights reserved ...

Page 3: ...stem Environment LED 12 Rear Panel Port LEDs 12 Supported Transceivers 12 Installing the Cisco UCS Fabric Interconnect 13 C H A P T E R 2 Preparing for Installation 13 Considerations and Warnings 13 Airflow Considerations 14 Fabric Interconnect Weight 14 Installation Guidelines 14 Cabinet and Rack Requirements 15 General Requirements for Cabinets and Racks 16 Requirements Specific to Perforated Ca...

Page 4: ... 31 Removing a Cable from a Transceiver 31 Maintaining SFP28 Transceivers and Fiber Optic Cables 32 Replacing Components 33 C H A P T E R 4 Preparing a Fabric Interconnect for Removal 33 Shutting Down a Fabric Interconnect 34 Removing a Cisco UCS Fabric Interconnect From a Rack 37 Repacking the Cisco UCS Fabric Interconnect for Return Shipment 38 Technical Specifications 39 C H A P T E R 5 System ...

Page 5: ... and United Arab Emirates 49 Israel 50 Italy 50 North America 51 Switzerland 52 Taiwan 52 United Kingdom 53 Cabinet Jumper Power Cords 53 Site Planning and Maintenance Records 57 C H A P T E R 7 Site Preparation Checklist 57 Contact and Site Information 59 Chassis and Module Information 60 Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide v Contents ...

Page 6: ...Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide vi Contents ...

Page 7: ...connect provides Ethernet and Fibre Channel to the servers in the system The servers connect to the fabric interconnect and then to the LAN or SAN Each fabric interconnect runs Cisco UCS Manager software to fully manage all Cisco UCS elements High availability redundancy can be achieved when a fabric interconnect is connected to another fabric interconnect through the L1 or L2 port on each device ...

Page 8: ...ists of Intel Xeon D 1528 v4 Processor 1 6 GHz 64 GB of RAM 8 MB of NVRAM 4 x NVRAM chips 128 GB SSD bootflash Figure 1 Cisco UCS 6454 Fabric Interconnect Rear View Ports 17 44 10 25 Gbps Ethernet or FCoE When using Cisco UCS Manager releases earlier than 4 0 4 ports 9 44 are 10 25 Gbps Ethernet or FCoE Note 2 Ports 1 16 Unified Ports 10 25 Gbps Ethernet or FCoE or 8 16 32 Gbps Fibre Channel When ...

Page 9: ... ports Each 40 100 Gb port can break out into 4 x 10 25 Gb uplink ports Sixteen ports 1 16 are unified ports that support 10 25 GbE or 8 16 32G Fibre Channel speeds The Cisco UCS 64108 Fabric Interconnect supports Maximum of 8 FCoE port channels Or 4 SAN Ports Or a maximum of 8 SAN port channels and FCoE port channels 4 each The Cisco UCS 64108 Fabric Interconnect also has one network management p...

Page 10: ...a breakout cable 4 Ports 89 96 1 10 25 Gbps Ethernet or FCoE 3 System status LED 6 System environment fan fault LED 5 Beacon LED 7 The Cisco UCS 64108 Fabric Interconnect has two power supplies redundant as 1 1 and three fans redundant as 2 1 Figure 4 Cisco UCS 64108 Fabric Interconnect Front View RS 232 serial console port RJ 45 connector 2 Cooling fans hot swappable 2 1 redundancy 1 Cisco UCS 64...

Page 11: ...nother device this may cause traffic disruption The port can be disabled and enabled after it has been configured Note The following table summarizes the Cisco UCS Fabric Interconnects Cisco UCS 6454 FI 54 Port Fabric Interconnect Description 1 RU Form factor 48 10 25G interfaces Number of fixed 10 GB Interfaces 16 This FI supported 8 unified ports ports 1 8 with Cisco UCS Manager 4 0 1 and 4 0 2 ...

Page 12: ...an operate as 10G 25G Ethernet Port types in 10G 25G mode FCoE uplink port Server port Appliance port the FI must be in Ethernet End Host mode Monitor port When using Cisco UCS Manager releases earlier than 4 0 4 ports 9 44 are 10 25 Gbps Ethernet or FCoE Only ports 1 8 were Unified Ports in earlier releases Note 2 Ports 1 16 Unified Ports can operate as 10 25 Gbps Ethernet or FCoE or 8 16 32 Gbps...

Page 13: ...s The two power supplies support 1 1 redundancy Table 1 Power Supply Models Wattage Source Fabric Interconnect Cisco PID 650 W AC 110 to 240 VAC Cisco UCS 6454 UCS PSU 6332 AC The Cisco UCS 6454 FI shares the same AC power supply and ordering PID with the Cisco UCS 6300 Series 1200 W AC 90 to 264 VAC Cisco UCS 64108 UCS PSU 64108 AC 930 W DC 48 VDC Cisco UCS 6454 Cisco UCS 64108 UCS PSU 6332 DC Th...

Page 14: ...tage over current or over temperature Solid amber Fault error LED AC power is present 3 3 VSB is on and the power supply is off Blinking amber Normal operation Off Fan Modules The Cisco UCS 6454 FI and the Cisco UCS 64108 FI use different fan modules Cisco UCS 6454 FI four fan modules The fans support 3 1 redundancy All fans are hot swappable but only one fan can be removed at a time Cisco UCS 641...

Page 15: ...the LED state definition table below When connecting L1 and L2 ports between FIs the maximum supported length of Ethernet CAT5e or CAT6 cable is 100 meters Note Figure 7 Cisco UCS 6454 FI Front Panel Ports and LEDs L2 high availability port 2 L1 high availability port 1 RS 232 serial console port RJ 45 connector 4 RJ45 Network Management Port 3 Beacon LED 6 USB port The USB port can be used for bo...

Page 16: ... Management Port RJ 45 5 USB port The USB port can be used for booting or downloading scripts 7 The definition of states of the beacon and system status LEDs are as follows Description State Color Function Location LED Chassis selected Solid On Blue Indicate selected chassis Front and rear Beacon LED Chassis not selected Off Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 10 ...

Page 17: ...e LEDs of the management port on the front panel are listed below Description LED State LED Position No link Off Left Physical link Solid green No activity Off Right Activity Blinking green L1 and L2 Port LEDs The states of the LEDs on the L1 and L2 front panel ports are listed below Description LED State LED Position No link Off Left Physical link Solid green Left No activity Off Right Activity B...

Page 18: ... Port LEDs The states of the LEDs on the rear panel ports are listed below Description LED State Enabled but SFP not inserted Administrative down software shutdown Yellow Enabled and link is up Green Enabled but link is not connected Off Power On Self Test POST failed Port beacon enabled Blinking yellow Supported Transceivers For a complete list of the supported transceivers and cables with orderi...

Page 19: ...uipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device Statement 1071 Warning SAVE THESE INSTRUCTIONS This unit is intended for installation in restricted access areas A res...

Page 20: ...08 FI weighs 35 86 lbs 16 27 kg Caution When lifting the system follow these guidelines Disconnect all power and external cables before lifting the system Ensure that your footing is solid and that the weight of the system is evenly distributed between your feet Lift the system slowly keeping your back straight Lift with your legs not with your back Bend at the knees not at the waist Installation ...

Page 21: ... power to the fabric interconnect are within the current ratings for the wiring and breakers Use the following screw torques listed in Newton metres when installing the fabric interconnect Captive screws 4 in lb 0 45 Nm M3 screws 4 in lb 0 45 Nm M4 screws 12 in lb 1 36 Nm 10 32 screws 20 in lb 2 26 Nm 12 24 screws 30 in lb 3 39 Nm Cabinet and Rack Requirements This section provides the requirement...

Page 22: ...erconnect and the side wall of the cabinet No sizeable flow obstructions should be immediately in the way of fabric interconnect air intake or exhaust vents Requirements Specific to Perforated Cabinets A perforated cabinet is defined here as a cabinet with perforated front and rear doors and solid side walls In addition to the requirements listed in the General Requirements for Cabinets and Racks ...

Page 23: ...d report any discrepancies or damage to your customer service representative Have the following information ready Invoice number of shipper see packing slip Model and serial number of the damaged unit Description of damage Effect of damage on the installation Required Equipment Before beginning the installation ensure that the following items are ready Number 1 and number 2 Phillips screwdrivers w...

Page 24: ...llips pan head screws 10 Rack mount guides 2 Slider rails 2 Procedure Step 1 Install the front rack mount brackets as follows a Position a front rack mount bracket against the FI and align the screw holes as shown below You can attach the front rack mount bracket at the front fan side or the rear port side of the FI depending on which side you want to locate on the cold aisle You can align any fou...

Page 25: ...e chassis If you are aligning the guide to holes that are near the front fan side of the chassis see callout 3 in the previous figure If you are aligning the guide to holes that are near the rear port side of the chassis see callout 7 in the previous figure b Attach the bracket to the chassis with two of the flat head M4 screws See callout 4 or 8 in the previous figure c Repeat Step 2 with the rea...

Page 26: ...ttached to them see the following figure b Align the two rear rack mount guides on either side of the chassis with the slider rails installed in the rack Slide the rack mount guides onto the slider rails and then gently slide the chassis all the way into the rack If the chassis does not slide easily try realigning the rack mount guides on the slider rails Figure 11 Sliding the FI Into the Rack Ste...

Page 27: ...ge supplies DC DC converters on the modules and is intended to satisfy the Telcordia Technologies NEBS requirements for supplemental bonding and grounding connections You must observe the following system grounding guidelines for your chassis You must install the NEBS ground connection with any other rack or system power ground connections that you make The system ground connection is required if ...

Page 28: ...s in the United States such as Florida are subject to more lightning strikes than are other areas Best grounding recommendations must be closely followed High Commercial building is located in an area where lightning storms frequently occur but is not subject to direct lightning strikes Best grounding recommendations must be closely followed Medium to high Commercial building contains a mix of inf...

Page 29: ...g or replacing the unit the ground connection must always be made first and disconnected last Statement 1046 Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Statement 1019 Warning We recommend grounding the fabric interconnect even if the rack is already grounded All power supplies must be grounded The receptacles of the AC pow...

Page 30: ...o the grounding pad Step 6 Ensure that the lug and cable do not interfere with other equipment Step 7 Prepare the other end of the grounding cable and connect it to an appropriate grounding point in your site to ensure adequate earth ground Starting the System Do not connect the Ethernet port to the LAN until the initial system configuration has been performed For instructions on configuring the s...

Page 31: ... baud 8 data bits no parity 1 stop bit Step 5 If the fabric interconnect will be running in a cluster with another fabric interconnect connect Ethernet cables between the L1 and L2 ports Connect Port L1 on fabric interconnect A to L1 on fabric interconnect B Connect Port L2 on fabric interconnect A to L2 on fabric interconnect B If the fabric interconnect and the UCS instance will be in standalone...

Page 32: ...ce representative Step 10 Complete the worksheets provided in Site Preparation Checklist for future reference Step 11 Configure the primary fabric interconnect as described in thr Configuration Guide for the version of Cisco UCS Manager that you are using The configuration guides are available at this URL http www cisco com c en us support servers unified computing ucs manager products installatio...

Page 33: ...ctions to the Cisco UCS Fabric Interconnect consider the following for each type of interface and gather all the required equipment before connecting the ports Cabling required for each interface type Distance limitations for each signal type Additional interface equipment required Connecting to the Console Port You can connect the console port to a modem If you do not connect it to a modem connec...

Page 34: ...se does not have a serial port you will need to use the Serial to USB adapter Be sure to install the drivers for your adapter Step 2 Start your terminal software Step 3 Configure the terminal software as follows The COM port for the connection you are about to establish is the connection to the fabric interconnect You may need to look in the computer s device manager to confirm this The other conn...

Page 35: ...h or hub Use a cross over cable to connect to a router interface Step 2 Connect the other end of the cable to the device Connecting to an SFP28 Ethernet or Fibre Channel Port Installing or Removing Cables into SFP Transceivers To prevent damage to the fiber optic cables do not place more tension on them than the rated limit and do not bend to a radius of less than 1 inch if there is no tension in ...

Page 36: ...ap and follow the instructions for its use Step 2 If a cable is installed in the transceiver a Record the cable and port connections for later reference b Press the release latch on the cable grasp the connector near the connection point and gently pull the connector from the transceiver c Insert a dust plug into the cable end of the transceiver If the transceiver does not remove easily in the nex...

Page 37: ... that it is correctly positioned before continuing For instructions on verifying connectivity see the Configuration Guide for the version of Cisco UCS Manager that you are using The configuration guides are available at this URL http www cisco com c en us support servers unified computing ucs manager products installation and configuration guides list html Removing a Cable from a Transceiver To pr...

Page 38: ...assis Do not remove and insert a transceiver more often than is necessary Repeated removals and installation can shorten its useful life Keep all optical connections covered when not in use If they become dusty clean before using to prevent dust from scratching the fiber optic cable ends Do not touch ends of connectors ensuring that they remain free of fingerprints and other contamination Clean re...

Page 39: ...hat if you remove both the primary and subordinate fabric interconnects or the single fabric interconnect from a standalone system you are shutting down the entire Cisco UCS domain Caution Procedure Step 1 Use Cisco UCS Manager to perform the following tasks a Back up your Cisco UCS Manager configuration b Shut down the OS on all servers in the Cisco UCS domain c Disable the Smart Call Home featur...

Page 40: ...er The cabling and port numbering should be same for the replacement fabric interconnect Step 3 Log into UCS Manager and verify the state of the A and B fabric interconnects either UP or DOWN From the CLI enter the show cluster extended state command High availability should be running in UCS Manager as indicated by HA is READY Example FI A show cluster extended state Cluster Id 0x537d0580bf9911e0...

Page 41: ...he fabric interconnect and it will automatically boot and run POST tests Basic System Configuration Dialog This setup utility will guide you through the basic configuration of the system Only minimal configuration including IP connectivity to the Fabric interconnect and its clustering mode is performed through these steps Type Ctrl C at any time to abort configuration and reboot system To back tra...

Page 42: ...Fabric interconnect Connecting to peer Fabric interconnect done Retrieving config from peer Fabric interconnect done Installer has determined that the peer Fabric Interconnect is running a different firmware version than the local Fabric Cannot join cluster Local Fabric Interconnect UCSM version 3 1 2c Kernel version 5 0 3 N2 3 12b System version 5 0 3 N2 3 12b local_model_no UCS FI 6454 Peer Fabr...

Page 43: ...is 1 serial FOX1344G1R1 state active Chassis 2 serial FOX1318GDKR state active FI A Step 15 Disable fabric evacuation and verify that traffic is flowing in both fabric interconnects Step 16 Apply the port license to the new fabric interconnect Removing a Cisco UCS Fabric Interconnect From a Rack Support both sides of the fabric interconnect when removing it from the rack The slider rail and front ...

Page 44: ...e rack Repacking the Cisco UCS Fabric Interconnect for Return Shipment If you need to return the fabric interconnect remove the fabric interconnect from the rack and repack it for shipment If possible use the original packing materials and container to repack the unit Contact your Cisco customer service representative to arrange for return shipment to Cisco Cisco UCS 6400 Series Fabric Interconnec...

Page 45: ...ication Description Height 1 72 in 44 mm Width 17 3 In 225 mm Length 22 5 in 571 mm Dimensions 22 lb 9 97 kg with two power supplies installed Weight ___ Table 5 Cisco UCS 64108 FI Physical Specifications Specification Description Height 3 38 in 85 9 mm Width 17 41 in 442 3 mm Length 24 14 in 613 2 mm Dimensions 27 4 pounds 12 4 kg with two power supplies installed Weight Cisco UCS 6400 Series Fab...

Page 46: ... Interconnect Note The Cisco UCS 6454 FI and the UCS 6300 Series FIs use the same 650 W AC power supplies so the ordering PIDs are the same Note Table 7 UCS 6454 FI Only 650 W AC Power Supply Specifications UCS PSU 6332 AC Specification AC Power Supply Properties 650 W Maximum output per power supply 100 to 240 VAC Input voltage 7 6 A 100 VAC 3 65 A 208 VAC Maximum AC input current 12 ms 50 load M...

Page 47: ...00 Series FIs and the UCS 6300 Series FIs use the same 930 W DC power supplies so the ordering PIDs are the same Note Table 9 UCS 6400 Series FIs 930 W DC Power Supply Specifications UCS PSU 6332 DC Specification DC Power Supply Properties 930 W Maximum output per power supply 48 VDC Input voltage 23 A maximum 48 VDC Maximum HVDC input current 8 ms 50 load Maximum holdup time 12 VDC Power supply o...

Page 48: ...hich damage to the device may occur if these limits are exceeded for other than a short period of time 2 Functional performance is not intended device reliability is not implied and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions General Specifications for Cisco Fibre Channel SFP Transceivers The table below l...

Page 49: ... power 3 Approximate actual distance may vary depending on fiber quality and other factors Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 43 Technical Specifications General Specifications for Cisco Fibre Channel SFP Transceivers ...

Page 50: ...Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 44 Technical Specifications General Specifications for Cisco Fibre Channel SFP Transceivers ...

Page 51: ...ar rack mount guides 2 front rack mount brackets 12 M4 x 0 7 x 8 mm Phillips countersunk screws 10 10 32 rack nuts 10 10 32 x 3 4 inch Phillips pan head screws 1 RS 232 console cable with an RJ 45 adapter and a DB9 adapter 1 ground lug kit 1 ESD wrist strap 1 power cord clip a wire clip that is used to retain the power cord 1 pointer document specifies where to find the online product documentatio...

Page 52: ...e P2 DB 9 Pins P1 P1 45 Pins Signal Name CTS 8 1 RTS DSR 6 2 DTR ZXD 2 3 TXD GND 5 4 GND GND 5 5 GND TXD 3 6 ZXD DTR 4 7 DSR RTS 7 8 CTS Console Port The console port is an asynchronous RS 232 serial port with an RJ 45 connector The table below lists the pinouts for the console port on the Cisco UCS 6454 Fabric Interconnect Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 46 C...

Page 53: ...3 outlet receptacles The jumper power cords for use in cabinets are available as an optional alternative to the standard power cords The standard power cords have an IEC C13 connector on the end that plugs into the power supplies The optional jumper power cords have an IEC C13 connector on the end that plugs into the power supplies and an IEC C14 connector on the end that plugs into an IEC C13 out...

Page 54: ... A 3112 Length 8 2 feet 2 5 meters Figure 15 CAB 9K10A AU Peoples Republic of China Power Cord SFS 250V 10A CN Plug 250 VAC 10 A GB 2009 Length 8 2 feet 2 5 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 48 Cable and Port Specifications Australia and New Zealand ...

Page 55: ... Length 8 2 feet 2 5 meters Figure 17 CAB 9K10A EU India South Africa and United Arab Emirates Power Cord SFS 250V 10A ID Plug 250 VAC 16A EL 208 Length 8 2 feet 2 5 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 49 Cable and Port Specifications Europe ...

Page 56: ... 250 VAC 10 A SI32 Length 8 2 feet 2 5 meters Figure 19 SFS 250V 10A IS Italy Power Cord CAB 9K10A IT Plug 250 VAC 10 A CEI 23 16 Length 8 2 feet 2 5 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 50 Cable and Port Specifications Israel ...

Page 57: ...g 250 VAC 13 A IEC60320 Length 6 6 feet 2 0 meters Figure 21 CAB AC 250V 13A CAB N5K6A NA Power Cord CAB N5K6A NA Plug 250 VAC 13 A NEMA 6 15 Length 8 2 feet 2 5 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 51 Cable and Port Specifications North America ...

Page 58: ... 250 VAC 10 A MP232 Length 8 2 feet 2 5 meters Figure 23 CAB 9K10A SW Taiwan Power Cord CAB ACTW Plug 125 VAC 10 A CNS10917 Length 7 5 feet 2 3 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 52 Cable and Port Specifications Switzerland ...

Page 59: ... Length 8 2 feet 2 5 meters Figure 25 CAB 9K10A UK Cabinet Jumper Power Cords Jumper Power Cord CAB C13 C14 JMPR Plug 250 VAC 10 A C13 C14 Connectors Length 2 2 feet 0 7 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 53 Cable and Port Specifications United Kingdom ...

Page 60: ... Connectors Length 9 8 feet 3 meters Figure 27 CAB C13 C14 AC Jumper Power Cord CAB C13 C14 2M Plug 250 VAC 10 A C13 C14 Connectors Length 6 6 feet 2 meters Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 54 Cable and Port Specifications Cabinet Jumper Power Cords ...

Page 61: ...Figure 28 CAB C13 C14 2M Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 55 Cable and Port Specifications Cabinet Jumper Power Cords ...

Page 62: ...Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 56 Cable and Port Specifications Cabinet Jumper Power Cords ...

Page 63: ...f your equipment is essential for successful system operation ventilation and accessibility Consider heat dissipation when sizing the air conditioning requirements for an installation Table 15 Site Planning Checklist Date Time Verified By Planning Activity Task No Space evaluation Space and layout Floor covering Impact and vibration Lighting Maintenance access 1 Cisco UCS 6400 Series Fabric Interc...

Page 64: ...Power receptacles Receptacle proximity to the equipment Dedicated circuit for power supply Dedicated separate circuits for redundant power supplies UPS for power failures 3 Grounding evaluation Circuit breaker size CO ground AC powered systems 4 Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 58 Site Planning and Maintenance Records Site Preparation Checklist ...

Page 65: ...AC source circuit 5 UPS uninterruptible power supply 6 EMI electromagnetic interference 7 RFI radio frequency interference Contact and Site Information Use the following worksheet to record contact and site information Table 16 Contact and Site Information Contact person Contact phone Contact e mail Building site name Data center location Floor location Address line 1 Address line 2 Cisco UCS 6400...

Page 66: ...Product Number________________________________________________ Table 17 Network Related Information System IP address System IP netmask Hostname Domain name IP broadcast address Gateway router address DNS address Modem telephone number Table 18 Module Information Notes Module Serial Number Module Type Slot Fixed 1 Expansion 2 Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 60...

Page 67: ...nnection Notes Port Channel Group LAN or SAN Pin Group Port FEX Chassis Port Slot 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 61 Site Planning and Maintenance Records Chassis and Module Information ...

Page 68: ...nnel Group LAN or SAN Pin Group Port FEX Chassis Port Slot 26 27 28 29 30 31 32 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cisco UCS 6400 Series Fabric Interconnect Hardware Installation Guide 62 Site Planning and Maintenance Records Chassis and Module Information ...

Reviews: