background image

 

 

 

 

 

LTC 8900 Series

 

 

 

en Installation Manual

 

Summary of Contents for LTC 8808/00 Series

Page 1: ...LTC 8900 Series en Installation Manual ...

Page 2: ......

Page 3: ...laneous Components 19 5 Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU 20 5 1 General Installation Considerations 20 5 2 LTC 8904 Series CPU Bay Installation 21 5 3 LAN Switch Installation 22 5 4 LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation 22 5 5 Module Insertion 23 5 6 Data Receiver Modules 23 5 7 LTC 8916 01 Data Receiver Modules 23 5...

Page 4: ...TC 8903 Series Input Bay Installation 39 6 6 Module Insertion 40 6 7 Data Receiver Modules 41 6 8 LTC 8916 01 Data Receiver Modules 41 6 9 LTC 8918 01 Data Receiver Modules 42 6 10 LTC 8934 00 Video Output Modules 43 6 11 LTC 8921 00 Video Input Modules 44 6 12 System Video Connections 45 6 12 1 Camera Input Connections 45 6 12 2 System Connections over 1024 Cameras 45 6 12 3 System Connections ov...

Page 5: ...ts 62 8 4 Control Data Lines in Satellite Systems 62 8 5 Satellite Sites Programming Requirements 62 8 6 Main Site Programming Requirements 63 8 7 Special Programming for Cascaded Satellite System Configurations 65 8 8 Alarm Inputs in Satellite Systems 66 9 Troubleshooting Guide 98 10 Maintenance Information 101 10 1 Cleaning System Keyboard s 101 10 2 Matrix Bay AC Line Voltage Input Selection 10...

Page 6: ...ungen für die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Precauciones de Seguridad Atención la instalación la debe realizar únicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su país Desconexión de la alimentación Las unidades con o sin interruptores de encendido apagado reciben alimentación eléctrica siempre...

Page 7: ...R RIDURRE IL RISCHIO DI SCOSSE ELETTRICHE NON RIMUOVERE LA COPERTURA O IL PANNELLO POSTERIORE L UNITÀ NON CONTIENE COMPONENTI INTERNI RIPARABILI DALL UTENTE PER QUALSIASI INTERVENTO RIVOLGERSI A PERSONALE TECNICO QUALIFICATO Questo simbolo indica la presenza di tensione pericolosa non isolata all interno del contenitore del prodotto Ciò comporta un potenziale rischio di scosse elettriche Si consig...

Page 8: ...and ensure reliable operation Do not block or cover these openings Do not place the unit in an enclosure unless proper ventilation is provided or the manufacturer s instructions have been adhered to 4 Water Do not use this unit near water for example near a bathtub washbowl sink laundry basket in a damp or wet basement near a swimming pool in an outdoor installation or in any area classified as a ...

Page 9: ...ly terminals If unsure of the type of power supply to use contact your dealer or local power company 12 Servicing Do not attempt to service this unit yourself Opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 13 Damage requiring service Unplug the unit from the main AC power source and refer servicing to qualified ser...

Page 10: ...ww BoschSecurity com standards Camera signal Protect the cable with a primary protector if the camera signal is beyond 140 feet in accordance with NEC800 CEC Section 60 Disposal Your Bosch product was developed and manufactured with high quality material and components that can be recycled and reused This symbol means that electronic and electrical appliances which have reached the end of their wo...

Page 11: ...he hard disk drives Outdoor signals The installation for outdoor signals especially regarding clearance from power and lightning conductors and transient protection must be in accordance with NEC725 and NEC800 CEC Rule 16 224 and CEC Section 60 Permanently connected equipment Incorporate a readily accessible disconnect device external to the equipment Pluggable equipment Install the socket outlet ...

Page 12: ...separately from Bosch Caution Connecting System ground to Safety ground may result in ground loops that can disrupt the CCTV system Video loss Video loss is inherent to digital video recording therefore Bosch Security Systems cannot be held liable for any damage that results from missing video information To minimize the risk of lost digital information Bosch Security Systems recommends multiple r...

Page 13: ...ons FCC et ICES modèles utilisés aux États Unis et au Canada uniquement Ce produit est conforme aux normes FCC partie 15 la mise en service est soumises aux deux conditions suivantes cet appareil ne peut pas provoquer d interférence nuisible et cet appareil doit pouvoir tolérer toutes les interférences auxquelles il est soumit y compris les interférences qui pourraient influer sur son bon fonction...

Page 14: ...EGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Bosch notices Video loss Video loss is inherent to digital video recording therefore Bosch Security Systems cannot be held liable for any damage that results from missing video information To minimize the risk of lost digital information Bosch Security Systems recommends multiple redundant record...

Page 15: ...al packing carton is the safest container in which to transport the unit and must be used if returning the unit for service Save it for possible future use Parts List This electronic equipment should be unpacked and handled carefully Part LTC 8901 or LTC 8904 Series Unit LTC 8902 Series and LTC 8903 Series Matrix Bays LTC 8943 95 PC System Controller PC Redundant Configurations Only LTC 8944 93 LT...

Page 16: ...ander units In addition the Allegiant Series have a Satellite configuration capability through which the system can communicate with up to 256 remote combinations of Allegiant Series switchers In standard system configurations the user can add a Windows based PC to simplify programming of the system using either the supplied LTC 8059 Master Control Software for Windows package or the optional LTC ...

Page 17: ...odules LTC 8910 and a relay module LTC 8917 LTC 8902 Series Output Bay The LTC 8902 Series Output Bays generate the text overlays for the video monitors Each bay accepts up to 8 LTC 8934 00 Video Output Modules providing output for up to 64 monitors For more outputs additional output bays can be used up to a maximum of 8 bays providing 512 monitor outputs Each LTC 8902 Series Input Bay includes on...

Page 18: ...ludes a rack mounted monitor a rack mounted keyboard Windows operating system and preloaded configuration software The LTC 8943 95 PC is supplied only if the system is purchased in the redundant design configuration The PC runs the System Supervisor Software that manages the CPU data mirroring and automatic switchover functions Since the PC is intended to configure and monitor the operation of the...

Page 19: ...ays LAN Cables Three types of LAN cables are supplied with the system The first type has a length of 8 m 25 ft The second type is 3 m 10 ft long The third type is 2 m 6 ft long and contain reversed data connections These shorter LAN cables are used exclusively for crossover connections between the LTC 8944 93 LTC 8945 93 and LTC 8946 93 LAN switches Security Key for PC based Software The Master Co...

Page 20: ...terconnect cabling will be easier to manage if the LTC 8902 Series Bays are mounted higher up in the rack above any LTC 8903 Series Input Bays 3 Camera and monitor video connections are NOT made directly to the LTC 8902 Series and LTC 8903 Series matrix bays All external video connections are made to LTC 8808 00 Video Interconnect Panels Each LTC 8808 00 panel accepts up to 32 video connections an...

Page 21: ...g screws and associated hardware are NOT included A LLE G IA NT M atrix C PU Power C PU A C TIV IT Y BOSCH Figure 5 2 LTC 8904 Series CPU Bay It is recommended that the CPU bay be mountedso that a 9 cm 3 1 2 in rack space is availableeither above or below the enclosure In sites where the system can not be taken out of operation for a period of time this will leave a mounting space available for a ...

Page 22: ...ideo Input bays are supplied with LTC 8805 Series power supplies Install the power supply in the far right position of the bay ensuring proper alignment and seating of the supply into the rear mating connector Verify that the power supply ON OFF switch is in the OFF position Figure 5 3 Typical Power Supply Insertion Install four 4 supplied screws and star washers on the rear panel of the bay s sur...

Page 23: ...ideo Output bays are supplied with LTC 8916 01 Data Receiver modules LTC 8903 Series Video Input bays are supplied with LTC 8918 01 Data Receiver modules Data Receiver Modules are installed into the right most slot adjacent to the power supply of the matrix bays as shown below Figure 5 5 Typical Data Receiver Module Insertion LTC 8916 01 Data Receiver Modules The LTC 8916 01 Data Receiver modules ...

Page 24: ...ibed below Verify that switches 1 to 3 and 5 to 8 on dipswitch S1 are OFF Switch 4 on S1 should be placed in the OFF position if the LTC 8903 Series bay will be used as a primary camera bay one that will have cameras directly connected to it If the LTC 8903 Series bay will be used as a secondary camera bay one that will have other LTC 8903 Series bays connected to its inputs place switch 4 on S1 i...

Page 25: ...dles 8 outputs If fewer than the maximum number of Video Output Modules are installed they should be installed from left to right with empty spaces on the right In some system configurations 8 or less LTC 8934 00 modules may be distributed between two 2 LTC 8902 Series Video Output bays This configuration assures partial system operation in the unlikely event of an LTC 8902 Series failure Since th...

Page 26: ... best fit your system configuration page 66 to page 66 in this manual The appropriate number of Video Input Modules LTC 8921 00 should be installed in the LTC 8903 Series main bay starting with the left most slot Each input module handles 32 inputs by 32 outputs Since the LTC 8903 Series supplies 64 outputs two 2 LTC 8921 00 input cards are required for each set of 32 cameras Odd numbered slots pr...

Page 27: ...LTC 8809 00 ribbon cables can reach the applicable matrix bay Note that rackmounting screws and associated hardware are NOT included The Video Input connectors are labeled with multiple levels If more than 256 cameras are used in a system multiple levels of input bays are used These system configurations are shown in page 66 through page 66 System Connections over 1024 Cameras If more than 1024 ca...

Page 28: ...8902 Series bays The LTC 8809 00 ribbon cables have keyed connectors on each end Maintain correct polarity when attaching between system components Refer to page 66 for typical system connections The LTC 8808 00 panels are typically installed on the rear of the mounting rack behind the applicable matrix bay They can be mounted elsewhere as long as the 2 m 6 ft LTC 8809 00 ribbon cables can reach t...

Page 29: ...ed ON on all cards Note that in the secondary level LTC 8903 Series cards are inserted only into slots 1 4 5 8 9 12 13 and 16 as depicted in page 66 through page 66 page 66 and page 66 LTC 8902 Series Terminators Dip switches S1002 S1003 S1004 and S1005 on the LTC 8934 00 Video Output Module are video termination switches All of these switches should be set to ON terminated This factory default co...

Page 30: ...power supplies located in the LTC 8902 Series and LTC 8903 Series matrix bays Initially the modules within the matrix bays should indicate the following conditions 1 The CPU ACT LEDS on all Data Receiver modules module next to power supply installed in the various matrix bays should blink randomly green The LAN LINK ACT LED will blink green to indicate communication with the Allegiant CPU The LAN ...

Page 31: ...switch over to the backup CPU occurs the system will be displaying the same cameras running the same sequences and otherwise replicating the state of the primary CPU prior to failure To perform Data Mirroring the system monitors all data changes in the primary CPU and sends copies of this data to the backup CPU Data Mirroring works for configuration tables such as camera titles and for real time e...

Page 32: ...his is detected by the LTC 8943 95 System Controller PC which then switches the communication ports to the backup CPU using the Switch Control input LTC 8943 95 System Controller PC Functions The System Controller uses a rack mount industrial grade PC to provide several important features in redundant LTC 8900 system configurations The System Supervisor software that runs on this PC provides user ...

Page 33: ...tch Connect Special 2 meter LAN Crossover Cable between Switches Using Any Port PC LAN Cable to LAN Switch Port 2 LTC 8945 93 LAN Switch LTC 8903 Camera Ba y LTC 8902 Monitor Ba y LTC 8901 CPU bay Figure 6 2 Data Connections for Redundant System Design LTC 8901 Series CPU Design Features The LAN switches provide the interbay communication for the system Since all systemcommunication is routed thro...

Page 34: ... complete failure or a failure of the CPU port i e port 1 automatic switch over will occur Video Bay Redundancy Considerations The LTC 8900 system was designed to provide redundancy for critical components Careful system design ensures that tolerance of single point failures is maintained For example if a single output bay is used in the system and the data receiver board in the bay fails the enti...

Page 35: ...s of the bays before installing them Four 4 holes are provided for mounting the bays in the rack Rack mounting screws and associated hardware are NOT included 2 With redundant system configurations install the LTC 8943 95 System Controller PC monitor and keyboard so that they are easily accessible for the system installer programmer NOTE The PC must be installed within 3 m 10 ft of the main CPU ba...

Page 36: ...t cables can be used Although not a requirement the matrix bay video interconnect cabling will be easier to manage if the LTC 8902 Series Bays are mounted higher up in the rack above any LTC 8903 Series Input Bays 4 Camera and monitor video connections are NOT made directly to the LTC 8902 Series and LTC 8903 Series matrix bays All external video connections are made to LTC 8808 00 Video Interconn...

Page 37: ...en the CPU and LAN switches The 8 m 25 ft length is used between the CPU and the video matrix bays in all system configurations The 2 m 6 ft length has reversed data connections and can only be used between the LTC 8944 93 LTC 8945 93 and LTC 8946 93 LAN switches H LTC 8902 Monitor Bay LTC 8902 Monitor Bay LTC 8944 LAN Switch LTC 8945 LAN Switch LTC 8903 Camera Bay LTC 8903 Camera Bay LTC 8903 Cam...

Page 38: ...urer The software supplied with the switches is not used The switches for the LTC 8900 systems are used in a network dedicated to only the LTC 8900 system The switches must not be connected to a computer network or any other network To use the switches in the LTC 8900 system follow the directions in this manual ONLY All data cables going to the switches connect to the front panel ports The main AC...

Page 39: ...M following the instructions supplied with the monitor rack kit Connect the supplied VGA cable to the PC If desired an available monitor output from the Allegiant or other composite video source can be connected to the video input using a coax with BNC connector Attach AC line cord but do not attach line cord to AC power source until instructed Keyboard Mouse Rack Installation The Keyboard Mouse r...

Page 40: ...do so NOTE The LTC 8902 Series and LTC 8903 Series bays should be installed so there is at least 4 5 cm 1 3 4 in of clearance above and below the bay to allow for proper cooling Failure to provide proper clearance may cause the equipment to exceed its recommended operating temperature range DO NOT install the LTC 8934 00 Video Output modules or the LTC 8921 00 Video Input modules into the matrix b...

Page 41: ...system configurations of up to 2048 cameras and 512 monitors page 66 can be used as a guide for setting the Data Receiver DIP switches Otherwise follow the procedure described below Verify that switches located on dipswitch S1 are all OFF On dipswitch S2 of the LTC 8916 01 verify that switches from 1 to 4 are OFF Switch 8 should be in the ON position Switches 5 through 7 determine the monitor numb...

Page 42: ...to it If the LTC 8903 Series bay will be used as a secondary camera bay one that will have other LTC 8903 Series bays connected to its inputs place switch 4 on S1 in the ON position If switch 4 on S1 has been set to the OFF position for use as a primary camera bay as described above set switches 1 to 4 on S2 according to the Primary Camera Bay Range in the table below 1 2 3 4 Camera Number Range O...

Page 43: ...mum number of Video Output Modules are installed they should be installed from left to right with empty spaces on the right In some system configurations 8 or less LTC 8934 00 modules may be distributed between two 2 LTC 8902 Series Video Output bays This configuration assures partial system operation in the unlikely event of an LTC 8902 Series failure Since this creates a gap in the monitor numbe...

Page 44: ...ams that best fits your system configuration among page 66 to page 66 in this manual The appropriate number of Video Input Modules LTC 8921 00 should be installed in the LTC 8903 Series main bay starting with the left most slot Each input module handles 32 inputs by 32 outputs Since the LTC 8903 Series supplies 64 outputs two 2 LTC 8921 00 input cards are required for each set of 32 cameras Odd nu...

Page 45: ...bbon cables can reach the applicable matrix bay Note rack mounting screws and associated hardware are NOT included The Video Input connectors are labeled with multiple levels If more than 256 cameras are used in a system multiple levels of input bays are used This type of system configuration is shown in page 66 through page 66 System Connections over 1024 Cameras If more than 1024 cameras are use...

Page 46: ... connectors on each end Maintain correct polarity when attaching between system components Refer to page 66 for typical system connections The LTC 8808 00 panels are typically installed on the rear of the mounting rack behind the applicable matrix bay They can be mounted elsewhere as long as the 2 m 6 ft LTC 8809 00 ribbon cables can reach the applicable matrix bay Note rack mounting screws and as...

Page 47: ...epicted in page 66 through page 66 page 66 and page 66 LTC 8902 Series Terminations Dip switches S1002 S1003 S1004 and S1005 on the LTC 8934 00 Video Output Module are video termination switches which should be set to ON terminated the factory default position This correctly terminates the outputs of the LTC 8903 Series bays into a 75 ohm load Like camera inputs monitor outputs on the Allegiant sy...

Page 48: ...TC 8944 93 LAN Switch to LTC 8945 93 LAN Switch Connections The LAN switches must be connected together using the supplied 2 m 6 ft crossover LAN cable Connect the LAN cable between any two ports on the two LAN switches LTC 8946 93 LAN Switch Connections When the combined quantity of LTC 8902 Series and LTC 8903 Series matrix bays exceeds 18 1 or more expansion LTC 8946 93 LAN switches are require...

Page 49: ...have a main AC power switch and should power up as soon as the main AC power cord is connected Verify that the CPU Selector switch on the front panel is set to Auto Select mode Initially the front panel LEDs of the CPU bay should indicate the following conditions 1 The power LEDs should be lit for both CPUs 2 Activity LEDs should be blinking for both CPUs 3 The In Use LED should be lit for the Pri...

Page 50: ...chover functions LTC 8901 Series CPU Relay Outputs and Buzzers The LTC 8901 Series main CPU bay provides five relay outputs that can be connected to devices to alert the operators if a failure is detected 1 2 3 4 5 6 7 8 9 10 11 12 Relay Out Figure 6 12 LTC 8901 CPU Rear Panel Relay Outputs page 50 defines the operations of the relay outputs Dry contact relays with the following specifications are...

Page 51: ...ause the communication signals to the matrix bays continues to be supplied from the primary CPU If the CPU bay front panel switch is used to manually select a CPU the appropriate LAN port enabling must still occur The System Controller performs this action even if the front panel switch is used to manually override automatic CPU selection If the System Controller is connected and the System Superv...

Page 52: ...d on the original LTC 8903 Series bay until vertical interval switching is achieved The PHASE ADJUST has a range of about 130 degrees If no external sync signal is used the matrix bays automatically use the AC power to generate an internal sync signal The EXT SYNC LED on the front panel of the power supply inside a matrix bay illuminates whenever the bay is receiving an external sync signal For LT...

Page 53: ...C running the LTC 8059 00 Master Control Software LTC 8850 00 Graphical User Interface software package or a custom program generating Command Console Language CCL commands Refer to the Allegiant Console Command Language manual for more information In redundant system configurations commands and data received by the CONSOLE port are directed to the active CPU inside the LTC 8901 Series CPU bay The...

Page 54: ...s 1 Data bits 8 Parity None Hardware handshaking RTS CTS ON NOTE The CONSOLE port does not provide a standardized pinout connection An interface cable designed for a standard serial printer connection is required Cable pinout information can be found at the end of this manual Attach the 9 pin male connector side of the cable to the LTC 8900 Series CPU bay connector labeled CONSOLE Apply power to t...

Page 55: ...n view control cameras from anywhere in the system For a 2 site system this is referred to as a dual master configuration In the same manner triple and quadruple master system configurations can also be configured Cascaded satellite systems where a Main site has a satellite which is a master to another satellite is another available scenario In fact it is possible to configure systems that include...

Page 56: ...e standard models and the only special requirement is to use either the optional LTC 8059 00 Master Control Software or the optional LTC 8850 00 GUI software package for initial programming of each Allegiant system Figure 8 2 Possible Allegiant Satellite System Configurations 8 1 56 en Satellite System Configuration Installations LTC 8900 Series 2015 01 10 6 Installation Manual Bosch Security Syst...

Page 57: ...runk lines cannot exceed the capacity of the system A single Main site switcher can control multiple satellite sites up to its video input limit If full matrix switching is required at the Main site the number of trunk lines from each satellite site must equal the number of monitors connected to the Main site switcher Multiple independently controlled Main site systems can be combined to provide l...

Page 58: ...ditional programming options if a multi level cascaded Allegiant satellite system configuration is being used Any alarm inputs to the Main site configured to activate satellite cameras operate normally except when limited by the number of available trunk lines The software automatically determines trunk usage depending on the priority level of operators currently viewing satellite cameras Alarm in...

Page 59: ...Figure 8 3 Conceptual Diagram of an Allegiant Satellite Switching System LTC 8900 Series Satellite System Configuration Installations en 59 Bosch Security Systems Inc Installation Manual 2015 01 10 6 ...

Page 60: ...Figure 8 4 Conceptual Diagram of a Dual Master Allegiant Satellite System 60 en Satellite System Configuration Installations LTC 8900 Series 2015 01 10 6 Installation Manual Bosch Security Systems Inc ...

Page 61: ...P T Z cameras ALLEGIANT Data Unit CODE POWER LTC 8569 RS 232 IN CODE OUT CODE IN RS 232 OUT Biphase Data Line to 3 rd Level Satellite Multiple Video TRUNK Lines Code Merger unit Data Converter Unit LTC 8780 Data Converter Unit Code Merger unit Typical PTZ Camera Typical PTZ Camera Typical PTZ Camera Video Typical System Monitors Video from all sites 1 2 3 4 5 6 7 8 9 0 Sh ot Mo n Pro d Cl r BOSC H...

Page 62: ... line coming from the Signal Distribution located at the main site This data line carries all pan tilt zoom control commands in addition to the switching commands generated by the main site switcher The control data line should be connected to an LTC 8780 Series Data Converter unit which provides address decoding functions for the satellite site An LTC 8780 Series is required for each satellite si...

Page 63: ... GUI Software make sure CPU DIP Switch 8 on Switch S2 is set to the ON position Main Site Programming Requirements At the main site the Camera ID Table must be programmed to ensure proper satellite operation It is easiest to start with the trunk line inputs For each trunk line the satellite s monitor output number and its bay address must be entered same number as the satellite s LTC 8780 address ...

Page 64: ...or outputs located at the main site should be selected to display a local camera via the system keyboard This prevents unused monitor outputs from using up trunk lines which may result in some confusing operational responses The Start up camera numbers listed in the Monitor Table of the LTC 8059 00 software should be programmed to specify locally connected cameras or a local unused input i e the r...

Page 65: ...s coming from the 3rd level satellite system may become used up making them unavailable to the operators at the intermediate system In this situation keyboard User Function 41 should be set to the NO REM CAM CACHE option at the master site location In this mode after the top level operator selects a locally connected camera the trunk line between the top level and the intermediate level system wil...

Page 66: ...error message i e error 81 via the satellite communication path and their camera will switch to the Start up camera specified in the Monitor Table Alarm Inputs in Satellite Systems Any alarm inputs to the main site which have been programmed to activate cameras located at satellites will operate normally except when limited by the number of trunk lines available The software automatically determin...

Page 67: ...ectors in the row are exactly the same All other connectors in the row are exactly the same All other connectors in the row are exactly the same All other connectors in the row are exactly the same All other connectors in the row are exactly the same LTC 8902 Monitor Bay LTC 8903 Camera Bay Figure 8 11 Ribbon Connector Key Polarity Diagram for Matrix Bays LTC 8900 Series Satellite System Configura...

Page 68: ... 8 on LTC 8903 Second Level S1 4 on S2 2 6 7 8 on LTC 8903 Second Level S1 4 on S2 2 5 8 on LTC 8903 Second Level S1 4 on S2 1 2 5 7 8 on LTC 8903 Second Level S1 4 on S2 1 2 5 6 8 on LTC 8903 Second Level S1 4 on S2 1 2 5 6 7 8 on LTC 8903 S1 all off S2 2 7 8 on LTC 8903 S1 all off S2 2 6 8 on LTC 8903 S1 all off S2 2 6 7 8 on LTC 8903 S1 all off S2 2 5 8 on LTC 8903 S1 all off S2 2 5 7 8 on LTC ...

Page 69: ...e 8 13 Rear Panel View of LTC 8902 Series and LTC 8903 Series Video Matrix Bays LTC 8900 Series Satellite System Configuration Installations en 69 Bosch Security Systems Inc Installation Manual 2015 01 10 6 ...

Page 70: ...F01U289924 Figure 8 14 Cable and Accessory Diagrams 70 en Satellite System Configuration Installations LTC 8900 Series 2015 01 10 6 Installation Manual Bosch Security Systems Inc ...

Page 71: ...mm Port 3 To Primary Controller of CPU Comm Port 4 To BackUp Controller of CPU PC Monitor Mouse Keyboard Ethernet Port Spare USB Figure 8 15 Typical LTC 8943 95 System Controller PC Rear Panels Applies to Redundant Systems Configurations Only LTC 8900 Series Satellite System Configuration Installations en 71 Bosch Security Systems Inc Installation Manual 2015 01 10 6 ...

Page 72: ...equence Upper LTC 8809 Ribbon Cable Camera Group 1 16 Lower LTC 8809 Ribbon Cable Camera Group 17 32 Ribbon Cable for the Camera group 241 256 Connects to Video Input Connector D in Group 4 LTC 8903 Camera Bay Ribbon Cable for Camera Group 1 16 Connects to the Video Input Connector A in Group 1 on the LTC 8903 Bay If applicable the Lower Row of Connectors is used for Video Looping Outputs Figure 8...

Page 73: ... Monitor Group 49 64 Lower LTC 8809 Ribbon Cable Monitor Group 17 32 Upper LTC 8809 Ribbon Cable Monitor Group 33 48 LTC 8902 Monitor Bay Upper LTC 8809 Ribbon Cable Monitor Group 1 16 Figure 8 17 System Monitor Connection Concept LTC 8900 Series Satellite System Configuration Installations en 73 Bosch Security Systems Inc Installation Manual 2015 01 10 6 ...

Page 74: ...y P o r t s 1 0 1 0 0 1 0 0 0 T T o r S F P S U s e o n l y o n e T o r S f o r e a c h P o r t 2 5 T 2 6 T 2 5 S 2 6 S LAN Data Line 1 3 5 7 5 1 1 2 4 6 8 1 0 1 2 h P P o w e r F a u l t P r o C u r v e S w it c h J 9 0 1 9 B R e s e t C l e a r L E D M o d e C o n s o l e 2 5 1 0 2 4 1 3 1 5 1 7 1 9 2 1 2 3 1 4 1 6 1 8 2 0 2 2 2 4 2 5 T a n d 2 6 T a r e I E E E A u t o M D I M D I X D u a l P e...

Page 75: ...t s 1 0 1 0 0 1 0 0 0 T T o r S F P S U s e o n l y o n e T o r S f o r e a c h P o r t 2 5 T 2 6 T 2 5 S 2 6 S 9 9 10 11 12 H LTC 8901 CPU Bay LTC 8945 93 LAN Switch LTC 8902 Monitor Bay LTC 8903 Camera Bay LTC 8903 Camera Bay Secondary LAN Data Line Primary LAN Data Line to Port 1 Backup LAN Data Line to Port 1 Typical Matrix Bay LAN Lines to Any Available Port on the LAN Switches Connect the 2m...

Page 76: ... T 2 6 T 2 5 S 2 6 S 1 3 5 7 5 1 1 2 4 6 8 1 0 1 2 h P P o w e r F a u l t P r o C u r v e S w it c h J 9 0 1 9 B R e s e t C l e a r L E D M o d e C o n s o l e 2 5 1 0 2 4 1 3 1 5 1 7 1 9 2 1 2 3 1 4 1 6 1 8 2 0 2 2 2 4 2 5 T a n d 2 6 T a r e I E E E A u t o M D I M D I X D u a l P e r s o n a l i t y P o r t s 1 0 1 0 0 1 0 0 0 T T o r S F P S U s e o n l y o n e T o r S f o r e a c h P o r t ...

Page 77: ...D Each Line Represents an LTC 8809 Ribbon Cable Each Line Represents an LTC 8809 Ribbon Cable LTC 8902 Monitor Bay Containing Modules for 64 Monitor Outputs LTC 8903 Camera Bay Containing 8 LTC 8921 Video Modules To Monitors via LTC 8808 Video Interconnect Panels LTC 8903 Camera Bay for Cameras 769 1024 LTC 8903 Camera Bay for Cameras 513 768 LTC 8903 Camera Bay for Cameras 257 512 LTC 8903 Camera...

Page 78: ...ibbon Cables LTC 8921 Video Input Modules LTC 8921 Video Input Modules LTC 8918 Data Receiver Module LTC 8905 Power Supply LTC 8808 Video Panels LTC 8809 Coax Ribbon Cables 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 4...

Page 79: ...Video Input Modules LTC 8921 Video Input Modules LTC 8918 Data Receiver Module LTC 8805 Power Supply LTC 8921 Video Input Modules LTC 8921 Video Input Modules LTC 8918 Data Receiver Module LTC 8805 Power Supply LTC 8906 Power Supply LTC 8916 Data Receiver Module LTC 8934 Video Output Modules LTC 8934 Video Output Modules LTC 8906 Power Supply LTC 8916 Data Receiver Module LTC 8934 Video Output Mod...

Page 80: ...03 Supplied Coax Ribbon Cables Supplied Coax Ribbon Cables Supplied Coax Ribbon Cables LTC 8809 Coax Ribbon Cables LTC 8809 Coax Ribbon Cables LTC 8809 Coax Ribbon Cables LTC 8809 Coax Ribbon Cables LTC 8808 Video Panels LTC 8808 Video Panels LTC 8808 Video Panels LTC 8808 Video Panels Additional Cameras 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr BOSCH 1 2 3 ...

Page 81: ...TC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8...

Page 82: ...C 8921 Video Input Modules are required in an LTC 8903 Bay with a 64 Monitor Bus Four LTC 8921 Video Input Modules in slot numbers 1 5 9 13 are required in an LTC 8903 Bay with a 32 Monitor Bus Internal Video Bus Concept of Secondary Level LTC 8903 or Cameras 1 to 1024 LTC 8809 Ribbon Cables Camera Range Monitor Bus Video Bus to LTC 8902 Bay for Monitors 33 to 64 Video Bus to LTC 8902 Bay for Moni...

Page 83: ...for 256 Camera by 32 Monitor System Module Termination and Interconnect Cabling for 256 Camera by 64 Monitor System Monitors 1 32 Monitors 33 64 Monitors 1 32 Lower LTC 8809 Ribbon Cable Lower LTC 8809 Ribbon Cable Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable 2 LTC 8809 Cables...

Page 84: ...903 Cameras 257 512 LTC 8903 LTC 8903 LTC 8903 LTC 8902 LTC 8903 8 LTC 8808 Panels are Required for Camera Inputs 257 to 512 8 LTC 8808 Panels are Required for Camera Inputs 257 to 512 2 LTC 8809 Cables are Required for 32 channel Video Bus to LTC 8902 4 LTC 8809 Cables are Required for 64 channel Video Bus to LTC 8902 4 LTC 8809 Cables are Required for 64 channel Video Bus to the LTC 8902 8 LTC 8...

Page 85: ...eo Input Modules are Required for Camera Inputs 513 to 768 8 LTC 8808 Panels are Required for Camera Inputs 513 to 768 4 LTC 8809 Cables are Required for 64 channel Video Bus to LTC 8902 4 LTC 8809 Cables are Required for 64 channel Video Bus to LTC 8902 8 LTC 8808 Panels are Required for Camera Inputs 1 to 256 Monitors 33 64 Monitors 1 32 LTC 8903 Cameras 257 512 LTC 8903 Cameras 1 256 LTC 8902 L...

Page 86: ...ower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable To Video In A To Video In B To Video In A To Video In B LTC 8903 LTC 8903 LTC 8903 LTC 8903 LTC 8902 8 LTC 8808 Panels are Required for Camera Inputs 257 to 512 Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable To Video In A To Video In B 8 LTC 8808 Panels are Required for Camera Inputs 513 to 768 Lower LTC 8809 Ribbon Cable Upper LTC 88...

Page 87: ...gs Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable D2 D C B A D C B A D C B A D C B A D C B A D C B A C1 D1 B1 A1 C2 B2 A2 Group Inputs 3 and 4 are used for additional LTC 8903 Camera Bay Connections LTC 8902 Monitor Bay Containing Modules for 64 Monitor Outputs Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable To Video In A To Video In B Each line Represents an LTC 8809 Ribbon Cable...

Page 88: ...Settings Primary LTC 8903 Bay Cameras 1 256 Primary LTC 8903 Bay Cameras 257 512 Primary LTC 8903 Bay Cameras 513 768 Primary LTC 8903 Bay Cameras 769 1024 LTC 8903 Bay Cameras 1025 1280 LTC 8903 Bay Cameras 1281 1536 LTC 8903 Bay Cameras 1537 1792 Primary LTC 8903 Bay Cameras 1 256 Primary LTC 8903 Bay Cameras 257 512 Primary LTC 8903 Bay Cameras 513 768 Primary LTC 8903 Bay Cameras 769 1024 LTC ...

Page 89: ...d Slots to ON all Primary LTC 8903 Bays Secondary Level LTC 8903 Bay for Camera Range 1 to 1024 Secondary Level LTC 8903 Bay for Camera Range 1025 to 2048 Front View Module Placement and Termination Settings 8 LTC 8921 Video Input Modules in Slots 1 4 5 8 9 12 13 and 16 are Required for 64 Monitor Systems Set all Termination Switches on LTC 8921 Modules in the Secondary LTC 8921 Bay to ON 8 LTC 89...

Page 90: ...8903 Bay Cameras 257 512 Primary LTC 8903 Bay Cameras 1 256 Primary LTC 8903 Bay Cameras 513 768 Primary LTC 8903 Bay Cameras 769 1024 Primary LTC 8903 Bay Cameras 1281 1536 Primary LTC 8903 Bay Cameras 1025 1280 Primary LTC 8903 Bay Cameras 1537 1792 Primary LTC 8903 Bay Cameras 1793 2048 Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable To Video In A To Video In B Lower LTC 8809 Ribbon Cab...

Page 91: ...ly 8 LTC 8921 Video Input Modules are Required in this Level for 256 Cameras because the LTC 8902 Output Bay Supports only 32 Monitors 4 LTC 8934 Video Output Modules are Required for Monitors 65 to 96 Set all Termination Switches to ON for all Modules Set all LTC 8921 Module Termination Switches Inside First Level LTC 8903 Bays to OFF LTC 8902 for Monitors 65 to 96 Second Level LTC 8903 Cameras 1...

Page 92: ...Required for Cameras 1 to 256 Set the LTC 8921 Module Termination Switches in EVEN Numbered Slots to ON Set the LTC 8921 Module Termination Switches in ODD Numbered Slots to OFF Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Monitors 33 64 Monitors 1 32 Monitors 65 96 Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Monitors 97 128 Each Line Represents an LTC 8809 Ribbon Cable Each...

Page 93: ...03 Bays Set the LTC 8921 Module Termination Switches in the ODD Numbered Slots to OFF in both Second Level LTC 8902 Bays Front View Module Placement and Termination Settings Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Monitors 33 64 Monitors 1 32 Monitors 65 96 Lower LTC 8809 Ribbon Cable Upper LTC 8809 Ribbon Cable Monitors 97 12...

Page 94: ... 769 1024 Video Looping Connections Video Looping Connections Video Looping Connections Video Looping Connections Set all LTC 8921 Module Termination Switches Inside First Level LTC 8903 Bays to OFF LTC 8902 for Monitors 1 to 64 Only 8 LTC 8921 Video Input Modules are Required in this Level for 256 Cameras because the LTC 8902 Output Bay Supports only 32 Monitors 4 LTC 8934 Video Output Modules ar...

Page 95: ...nnections Video Looping Connections Video Looping Connections Video Looping Connections Set all LTC 8921 Module Termination Switches inside First Level LTC 8903 Bays to OFF LTC 8902 for Monitors 1 to 64 8 LTC 8934 Video Output Modules are Required for Monitors 65 to 128 Set all Termination Switches to ON on all Modules LTC 8902 for Monitors 65 to 128 Video Interconnect LTC 8809 Cables Video Interc...

Page 96: ...Switches on the LTC 8921 Modules in Secondary LTC 8921 Bays to ON 8 LTC 8921 Video Input Modules in Slots 1 4 5 8 9 12 13 and 16 are Required Install the LTC 8921 Modules in ODD Numbered Slots only in Second Level Primary Bays Set all Termination Switches to ON Only 8 LTC 8921 Video Input Modules are Required in the Second Level Bays because the Second level LTC 8902 Output Bay Supports only 32 Mo...

Page 97: ... LTC 8921 Modules in Secondary LTC 8921 Bays to ON 8 LTC 8921 Video Input Modules in slots 1 4 5 8 9 12 13 and 16 are Required Set the LTC 8921 Module Termination Switches in EVEN Numbered Slots to ON in all Primary Second Level LTC 8903 Bays Set LTC 8921 Module Termination Switches in ODD Numbered Slots to OFF in all Primary Second Level LTC 8903 Bays 16 LTC 8921 Video Input Modules are Required ...

Page 98: ...with any unit fuse indicators Intermittent video output or system operation Verify that all circuit card modules are properly seated in their respective rack connectors Power Supply LEDs are lit but there is no power indication on modules or accessory devices Verify proper seating of the power supply within card cage Verify that the supplied retaining screws are installed Keyboard Checkout There a...

Page 99: ...matic hot switch to backup System completely operational LTC 8901 Series buzzers sound fault LEDs illuminate and appropriate fault relays close The System Supervisor software flashes and beeps to alert the operator LAN Switch CPU Port Not Applicable Automatic hot switch to backup occurs The System is completely operational System Supervisor software flashes and beeps to alert operator LAN Switch V...

Page 100: ...Flashing at paced rate indicates collisions D0500 SDU ACT Green Flashes at Biphase data packet rate D0701 CONSOLE Green Lit when RS 232 connection exists D0702 PRINTER Green Lit when RS 232 connection exists D0700 ALARM Green Lit when RS 232 connection exists D0900 LED1 Red Lit when flash memory is getting updates D0901 LED2 Green No function D0902 LED3 Yellow No function D0903 LED4 Red No functio...

Page 101: ...tor is located on the rear of the equipment bay inside the line cord connector housing The present input voltage selection is shown in the window of the connector housing Remove the AC line cord if the setting is incorrect To change the setting insert a flat blade screwdriver into the slot at one end of the connector housing as indicated in the drawing and rotate the screwdriver until the door to ...

Page 102: ...t breaker equipped power switch that can be reset from the front If the line fuse must be replaced in an LTC 8805 60 or LTC 8906 60 model remove the line cord from the system Insert a flat blade screwdriver into the slot at one end of the connector housing and rotate the screwdriver until the door to the housing opens Remove the fuse holder from the housing as shown below Figure 10 3 Fuse Removal ...

Page 103: ...an be swapped out In redundant system configurations the unique Data Mirroring functions of the System Supervisor PC software can be used to automatically configure the new LTC 8901 Series CPU bay making the replacement almost transparent to the system For example if the primary CPU has failed in the LTC 8901 Series CPU bay the system will have automatically switched to the backup CPU and continue...

Page 104: ...ersonnel only The memory backup batteries are located on the CPU card s inside the LTC 8900 CPU bay The batteries provide RAM memory backup for a period of at least one year They are only active when main AC power to the system has been lost The RAM memory is used to store system operational data which is frequently changing including time date and system crosspoint data i e which camera is curren...

Page 105: ...tacts the socket by seating the battery until it is somewhat flush with the level of the battery holder Repeat procedure for other battery plus 2 on other CPU if LTC 8901 Redundant CPU bay is in use Reattach front cover lid and re install into rack mount unit Re attach power and other interface cables Verification of the system s time and date and sequence programming should be made to insure no i...

Page 106: ...n 6 R D 7 No Connection 8 No Connection B 1 8 Relay Connector LTC 8901 only 1 2 Relay Primary Power Supply Fault 3 4 Relay Primary CPU Fault 5 6 Relay Backup Power Supply Fault 7 8 Relay Backup CPU Fault 9 10 Relay Any Fault 11 12 Input Silence Buzzer B 1 9 Console Cable The LTC 8506 00 cable that connects the Allegiant s CPU CONSOLE Port to an external PC uses the following pinouts 9 pin Male All...

Page 107: ......

Page 108: ...Bosch Security Systems Inc 850 Greenfield Road Lancaster PA 17601 USA www boschsecurity com Bosch Security Systems Inc 2015 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Reviews: