background image

Communications Systems | LBB 190x/10 and LBB 191x/10 Plena Mixer Amplifiers

The Plena mixer amplifier is a versatile, high-performance
unit with four mono microphone inputs and a music input.
It fulfills a wide variety of public address requirements at
a surprisingly low cost.

Functions

All input channels have a phantom power supply to
provide power to condenser microphones and selectable
speech filters for improved intelligibility. Input channels 3
and 4 can also be switched to line sensitivity. Separate
music inputs are available with their own input selector
and volume control.

Input channel 1 can take priority over all other
microphone and music inputs. Contact closure on the 5-
pin DIN connector, or if the signal level on channel 1
exceeds a predefined value (VOX) will activate priority. A
2-tone chime can be configured to precede a priority
announcement. A telephone or emergency input with VOX
activation and its own preset volume control overrides all
other input.

Loop through input and output connections enable
external sound processing equipment, such as an
equalizer or the Plena feedback suppressor, to be
connected between the preamplifier and the power
amplifier stages. An LED VU-meter monitors the master
output. The unit also has a tape output channel.

The Plena mixer amplifiers come in a range of maximum
output power. This power is directly available on 70 V and
100 V constant voltage connections and on a low
impedance connection for an 8 ohm load. Moreover, the
amplifiers have a separate 70 V / 100 V call-only output
channel for addressing areas where only priority
announcements are required, and a 70 V / 100 V mix-only
output channel for areas where no priority
announcements should be heard. The call-only output can
also be used for 3-wire remote, volume control override.
For more output power than the built-in power stage can
deliver, additional Plena power amplifiers can be
connected to the balanced line output in a loop-through
arrangement.

The LBB 1914/10 offers the same functionality as the
LBB 1912/10 but also has two front-panel switches to
direct the amplifier output to two separate zones. This is
useful when certain announcements or background music
should not be heard in part of a building. Priority calls,
however, are always routed to both zones.

LBB 190x/10 and LBB 191x/10 Plena

Mixer Amplifiers

Range of single and dual zone mixer amplifiers from

30 W to 120 W

Four low-noise balanced inputs for microphone or line

Selectable priority & VOX switching on microphone

input 1

Optional 2-tone chime to precede announcements

VOX activated emergency override

Outputs for normal, call-only and mix-only zones

Choice of CD, tuner or auxiliary music inputs

www.boschsecurity.com

Summary of Contents for LBB 1903/10

Page 1: ...e output channel The Plena mixer amplifiers come in a range of maximum output power This power is directly available on 70 V and 100 V constant voltage connections and on a low impedance connection for an 8 ohm load Moreover the amplifiers have a separate 70 V 100 V call only output channel for addressing areas where only priority announcements are required and a 70 V 100 V mix only output channel...

Page 2: ...x 10 rear view Parts Included Quantity Components 1 LBB 190x 10 Plena Mixer Amplifier or LBB 191x 10 Plena Mixer Amplifier 1 Power cord 1 Set of 19 mounting brackets 1 Installation and User Instructions Technical Specifications Electrical Mains power supply Voltage 230 115 VAC 10 50 60 Hz Inrush current LBB 1903 10 4 5 9 A 230 115 VAC LBB 1906 10 5 A 10 A 230 115 VAC LBB 1912 10 LBB 1914 10 8 16 A...

Page 3: ... Nominal level 1 V Impedance 100 ohm Tape output 1 x Connector Cinch 2 x mono Nominal level 350 mV Impedance 1 5 kohm Loop through output 1 x Connector Cinch Nominal level 1 V Impedance 100 ohm Loudspeaker output 70 100 V Connector Screw floating Power Max rated LBB 1903 10 45 30 W Mains power supply LBB 1906 10 90 60 W LBB 1912 10 LBB 1914 10 180 120 W Loudspeaker output 8 ohm Connector Screw flo...

Page 4: ... Communications Systems 12000 Portland Avenue South Burnsville Minnesota 55337 USA Phone 1 800 392 3497 Fax 1 800 955 6831 audiosupport us bosch com www boschsecurity com Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Robert Bosch SEA Pte L...

Page 5: ...Plena Mixer Amplifier Installation and Operating Manual LBB 1903 10 LBB 1906 10 LBB 1912 10 LBB 1914 10 en ...

Page 6: ......

Page 7: ... plug still fails to fit contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the polarised plug Alternatively this unit may be equipped with a 3 wire grounding type plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electricia...

Page 8: ...y precautions Warning Follow these instructions to prevent personal injury Caution Follow these instructions to prevent damage to the equipment Note Read these instructions for tips and other useful information Warning Do not open the unit when it is connected to the mains The unit contains non insulated parts which can cause electric shock Caution There are no user serviceable parts inside the un...

Page 9: ...6 and LBB1912 11 2 5 Setting the output voltage for LBB1914 11 3 Installation in rack 12 4 External settings and connections 13 4 1 Connect the DC supply battery 13 4 2 Priority microphone 13 4 3 Chime ON OFF switch 14 4 4 Microphone inputs 15 4 5 Emergency input 15 4 6 Music source inputs 16 4 7 Connecting the line output 16 4 8 Connecting loudspeakers 17 4 8 1 Constant voltage loudspeakers 17 4 ...

Page 10: ...Plena Mixer Amplifier Installation and Operating Manual Table of Contents en 6 Bosch Security Systems 2003 09 3922 988 92883en ...

Page 11: ...rces The power amplifier has a direct output for mixed signals and priority announcements but additionally a priority controlled output relay routes the output to loudspeaker zones that should receive only priority announcements or no priority announcements at all About the mixer amplifier LINE MIC LINE MIC INS In IN Click suppression S Out Phantom Power 201 0 0 0 8 O hm 8 O hm 70V 100V 100V 70V J...

Page 12: ...0 1 Power button 2 VU meter LED s for 20 6 0 dB and Power ON 3 Input 1 microphone volume control 4 Input 2 microphone volume control 5 Input 3 microphone volume control 6 Input 4 microphone volume control 7 Line music source volume control 8 Music source selector CD tape AUX 9 Master tone control treble 10 Master tone control bass 11 Master volume control all inputs except emergency 12 Zone 1 sele...

Page 13: ... connectors 12 Line output XLR 13 Tape output 2x phono connectors 14 Insertion input output 2x phono connectors 15 Loudspeaker output terminals and 24 Vdc power supply terminals 16 Mains connector 3 pole 17 Earth connection screw 18 Mains fuse LBB1903 T1A 230 Vac T2A 115 Vac LBB1906 T1 6A 230 Vac T3 15A 115 Vac LBB1912 T2 5A 230 Vac T5A 115 Vac LBB1914 T2 5A 230 Vac T5A 115 Vac 19 Mains voltage 11...

Page 14: ...ng off the lower frequencies of the signal To activate this filter for each microphone input set the respective filter jumper JP401 for input 1 JP402 for input 2 JP403 for input 3 and JP405 for input 4 to ON Internal settings Mic 1 Mic 2 Mic 3 Mic 4 VOX OFF ON 1 2 3 1 2 3 70V JP802 LBB1903 10 LBB1906 10 LBB1912 10 100V 1 2 3 1 2 3 JP405 JP403 JP402 JP401 VR401 JP802 70V 100V JP406 Mic 1 Mic 2 Mic ...

Page 15: ...ed by a priority relay The Call Only output only provides priority announcements while the Mix Only output just provides the mixed signals and switches off at priority calls 2 5 Setting the output voltage for LBB1914 Jumper JP901 sets the Call Mix Zone 1 Zone 2 Call Only and Mix Only outputs to 70 V or 100 V output Setting JP902 can also set the direct Call Mix output to 8 Ohm for low impedance lo...

Page 16: ...t the feet the unit is 2U high Installation in rack 115V 230V Apparatus delivered connected for 230V Rated input power 400VA This apparatus must Warning Call Mix 24VDCIn Call Only Mix Only 70 V0 100 70V 0 100 70V 0 8 0 12 VDC 12 VDC F LBB1903 30W F F5A LBB1906 60W F F8A LBB1912 120W F F15A LBB1914 120W F F15A 115V 2 30V Apparat us delivered connect ed for 230V Rated input power 400VA This apparatu...

Page 17: ...ut power 400VA This apparatus must Warning Call Mix 24VDCIn Call Only Mix Only 70 V0 100 70V 0 100 70V 0 8 0 12 VDC 12 VDC F LBB1903 30W F F5A LBB1906 60W F F8A LBB1912 120W F F15A LBB1914 120W F F15A 115V 230V Appara tus deliver ed connec ted for 230V Rated input power 400VA This appara tus must be earthed Warnin g 2 1 3 4 Mic L ine Mic L ine CD L R Aux Line Out 1V Inc Out In Tel Em er 0 0 2 Chim...

Page 18: ... 3 Depending on the position of the chime ON OFF switch 1 switching on microphone 1 will activate the chime The default chime volume is 8 dB 40 V which will be sufficient in most applications The volume can be altered using the potentiometer VR401 on the main PCB of the unit see 2 3 Note Only use one of the two connection possibilities of each microphone input Note Only when connecting a 5 pole DI...

Page 19: ... provides adequate isolation between the telephone network PBX and the Plena system The telephone coupler must also meet all relevant requirements for this type of communication equipment as imposed by law and or responsible telecommunication organisations in the country of use Never try to make a direct connection between the telephone network and the mixer amplifier External settings and connect...

Page 20: ... Line CD R Aux Line Out 1V Inc Tel Emer 0 0 2 Chime 4 5 1 3 10 CD PLAYBACK TUNER LBB1961 RECORD 13 TAPE 115V 230V Appar atus deliver ed conne cted for 230V Rated input power 400VA This appara tus must be earthe d Warni ng 2 1 3 4 Mic L ine Mic L ine CD L R Aux Line Out 1V Inc Out In Tel Em er 0 0 2 Chim e 4 5 1 3 Call M ix 24VDC In Call Only Mix Only 100V 0 70V 0 100 70 V 0 100 70 V 0 8 0 Repeat P...

Page 21: ...ons 115V 2 30V Apparat us delivere d connect ed for 230V Rated input power 400VA This apparatu s must be earthed Warning 2 1 3 4 Mic Lin e Mic Lin e CD L R Aux Line Out 1V Inc Out In Tel Em er 0 0 2 Chime 4 5 1 3 Call Mi x 24VD CIn Cal l Only Mix Only 100 V 0 70 V 0 100 70 V 0 100 70 V 0 8 0 Call Mix direct out 100V Call Mix direct out 70V Call Only 100 70V Mix Only 100 70V 8 Ohm Call Mix direct o...

Page 22: ... 4 9 Mains connection Figure 4 11 Use the supplied mains cord to connect the system to the mains supply Note If necessary set the switch 115 230 V to the required voltage using a sharp object e g a small screwdriver 115V 230V Apparatus delivered connected for 230V Rated input power 400VA This apparatus must be earthed Warning IGN QUALITY LIPS HOLLAND 24VD CIn Call Only Mix Only 00 70V 0 100 70V 0 ...

Page 23: ... and tone control Use the master volume control 11 to control the volume of the music microphone mix The treble and bass tone controls 9 and 10 affect the microphones as well as the music 5 3 Zone selection LBB1914 10 only Use the zone selection buttons 12 and 13 to route the music microphone mix from the amplifier output to loudspeaker zone 1 and or loudspeaker zone 2 Priority announcements howev...

Page 24: ... 8 dB 100 Hz Treble control 8 8 dB 10 kHz 6 3 Inputs Input 1 5 pin DIN balanced with phantom power 6 3 mm phone jack Input 2 3 pin XLR balanced with phantom power 6 3 mm phone jack Sensitivity 1 mV Impedance 1 kOhm S N flat at max volume 63 dB S N flat at min volume muted 75 dB CMRR 40 dB 50 Hz 20 kHz Headroom 25 dB Speech filter 3 dB 315 Hz high pass 6 dB oct Phantom power supply 16 V via 1 2 kOh...

Page 25: ...inal level 1 V Impedance 10 kOhm 6 4 Outputs Master output 1 3 pin XLR balanced Nominal level 1 V Impedance 100 Ohm Tape output Cinch 2x mono Nominal level 350 mV Impedance 1 5 kOhm Interconnection Cinch Nominal level 1 V Impedance 100 Ohm Loudspeaker outputs Screw floating Max rated output power 70 100 V LBB1903 10 45 W 30 W LBB1906 10 90 W 60 W LBB1912 10 LBB1914 10 180 W 120 W 8 Ohm output LBB1...

Page 26: ...on acc to EN 55103 1 EMC immunity acc to EN 55103 2 Acoustic noise level of fan 40 dB SPL 1 m LBB1912 10 and LBB1914 10 only Dimensions 100 x 430 x 270 mm 19 wide 2U high Weight LBB1903 10 approx 5 kg LBB1906 10 approx 8 5 kg LBB1912 10 LBB1914 10 approx 10 5 kg 19 mounting brackets LBC1901 00 to be ordered separately Technical data ...

Page 27: ......

Page 28: ...For more information visit www boschsecuritysystems com Bosch Security Systems B V Data subject to change without notice 2003 09 3922 988 92883en ...

Reviews: