background image

VCI

 

User Manual

Summary of Contents for KT700VCI

Page 1: ...VCI User Manual ...

Page 2: ......

Page 3: ...pment connection 14 6 1 Diagnostic connection 14 6 2 Selfcheck connection 15 6 3 Firmware upgrade connection 15 7 Initial Start up 16 8 VCI system settings 16 8 1 System Settings 16 8 1 1 Language Settings 16 8 1 2 System information 16 8 1 3 User information 16 8 1 4 Proxy Settings 16 8 1 5 Product Activation 17 8 2 Software upgrade 17 8 2 1 Software Upgrade 17 8 2 2 VCI Firmware Upgrade 17 8 3 V...

Page 4: ...f several steps e One step operation Instruction consisting of one step Intermediate result An instruction produces a visible inter mediate result Final result There is a visible final result on comple tion of the instruction 1 2 On the product Observe all warning notices on products and ensure they remain legible 2 Important notes Before start up connecting and opera ting Bosch Automotive Diagnos...

Page 5: ... to claim for damages Liability All data in this program is based where possible on manufacturer and importer details Bosch Automotive Diagnostics Equipment Shenzhen Limited does not accept liability for the correctness and completeness of software and data liability for damage caused by faulty software and data is ruled out Whatever the event Bosch Automotive Diagnostics Equipment Shenzhen Limite...

Page 6: ...d in good time R R The test is to take the electrical engineering princip les relating hereto into account R R Upon request of the trade association a test manual is to be maintained into which specific entries are made 3 Safety instructions 3 1 Risk of electric shocks 3 1 1 Low voltages high voltages Hazardous voltages occur in both the lighting system and the electrical system of a motor vehicle...

Page 7: ...ternal damage The insulation of the high voltage wiring must be intact and undamaged Watch out for any abnormal deformation of the high voltage wiring 3 2 Danger of acid burning When exhaust gas measurements are taken the sampling hoses which are used release a highly caustic gas hydrogen fluoride that can cause acid burning in the respiratory system when heated to temperatures in excess of 250 C ...

Page 8: ...ns allow the engine to cool down first then disconnect the plug of the fan motor Route cables at a suitable distance from rotating parts Secure the trolley against rolling away by setting the brakes Do not place heavy objects on or lean on the sensor holder Transport and operate the equipment only in ac cordance with the operating instructions 3 4 Danger of burning When working on a hot engine the...

Page 9: ...haust gas are heavier than air and settle at the bottom of the pit Caution is also necessary when working on LPG driven vehicles Safety measures Always ensure effective ventilation and suction es pecially when working in a pit Always switch on and connect the suction plant in a closed area 3 7 Noise Noise levels in excess of 70 dB A can occur when measurements are carried out on a vehicle especial...

Page 10: ...ly a large number of applications and devices employ this frequency band for transmission This can result in frequency interference Depending on ambient conditions the WLAN link may therefore deteriorate e g in the case of Bluetooth links cordless telephones radio controlled thermometers radio controlled garage door openers radio controlled light switches or radio controlled alarm systems i i Blue...

Page 11: ...el on the access point If pos sible avoid using neighboring channels to channels that are already in use R R We recommend that encryption of radio communica tions is configured at the access point 3 11 Satety Warning R R Inspection shall be carried out in good ventilation Connect the exhaust pipe to outside if there is no enough ventilation R R Smoking and open fire are prohibited in the inspec ti...

Page 12: ... that instruments and PC connection to pre vent signal interruption affect the test If it is found Can not be properly connected please unplug the communication cable to plug it back again not in the course of Violently shaking the lines of communica tion 3 13 Notes for operation of automobile ECU Pay attention to the following when diagnosing the au tomobile equipped with computer control system ...

Page 13: ... all protocols please click the Accept I button 4 Select the target folder for software installation disc C is the default file location you can click the Browse button to select the target folder and the program will automatically detect the corresponding used and free spaces of target disc 5 Click the Installation button and the software will be under installation please wait for the installatio...

Page 14: ...ter 8 LAN cable 9 USB cable 10 Alligator clip 11 Cigarette igniter connector 5 Introduction to VCI host 5 1 Host identifications Identifi cation Description The power indicator lamp lighting in green to indi cate the normal power supply The computer communication indicator lamp ligh ting in green to indicate the wired connection or in yellow to indicate the wireless connection The malfunction indi...

Page 15: ...ction 15 en 6 2 Selfcheck connection 1 2 3 4 5 VCI004 Fig 4 Selfcheck connection 1 Power adapter 2 VCI host 3 USB cable 4 LAN cable 5 Computer 6 3 Firmware upgrade connection 1 2 3 4 VCI005 Fig 5 Firmware upgrade connection 1 Power adapter 2 VCI host 3 USB cable 4 Computer ...

Page 16: ...Click the OK button and the interface will prompt Effective after System Restart 3 The language settings will be effective after the system restart 8 1 2 System information The system information includes the product serial number instrument type machine type software versi on and activation status 8 1 3 User information The user information includes the contact information telephone number mainte...

Page 17: ...e upgrade includes software upgrade and VCI firmware upgrade This function is available only after the product activati on If not display Not activation i i Before upgrade please ensure the normal connec tion between the VCI and computer i i Ensure the integrity of the upgrade process by not forcing to terminate the program 8 2 1 Software Upgrade Software upgrade includes application software up g...

Page 18: ... 3 1 3 WLAN Settings The wireless network settings include the P2P mode and the route mode Please ensure WLAN normally connected of computer Operation Steps for P2P mode 1 Select the P2P mode 2 Click the Scan Network button to search the availa ble wireless network 3 Select the available wireless network click the OK button and the interface will display the information concerning all networks con...

Page 19: ...d feedback The display area for vehicle series including All Chinese American European Japanese Korean OBD II and his tory record The display area for testable vehicle models including all testable vehicle models of each vehicle series The display area for additional functions including brand search The status column including diagnosis path VCI connec tion status and VMI connection status The scr...

Page 20: ...ion or brand search into diag nostic system 9 4 Diagnostic 9 4 1 Introduction to Main Interface of Diagnosis System After you access the diagnosis system the VCI software interface will display all diagnosis functions that can be achieved by this system No Description The display area for diagnosis functions it shows all dia gnosis functions of this system The display area for help information it ...

Page 21: ...diagnosis software 9 4 3 2 Reading Freeze Frame In the engine management system the freeze frame function is supplementary to the fault code function It is basically used to freeze the relevant working con ditions of engine when engine fault arises helping the service personnel know the working conditions of the whole vehicle upon the fault occurrence Operation Steps 1 Select a fault code and clic...

Page 22: ...data stream Viewing the next page of data stream 9 4 5 1 Capturing Data It records the data stream being tested Operation Steps 1 Click the Capture Data button and start to record the current value of data stream you may turn the pages to record all data streams If you do not turn the pages only the data stream displayed in the current screen will be recorded 2 Click the Save button to save the da...

Page 23: ... it with the selec table data streams the system provides 3 optio nal periods i e 250 ms 500 ms and 1000 ms the default period is 250 ms Maximum Records according to the period the system will automatically match it with maximum records Record Time it can be manually set to 10 min as a minimum and 120 min as a maximum the default record time is 120 min Trigger Time it can be manually set to 20 s a...

Page 24: ...e CSV format to the path as assigned 5 Click Exit to quit the Play Back Data Streams function i i You may also proceed to the Play Back Data Streams function through the Playback button at the main interface of software i i The software interface provides a time progress bar through which you can view the duration of current playback 9 4 8 Action Test This function is used to test whether the exec...

Page 25: ...h the information relevant to detection record any blank marked with must be filled in otherwise it is impossible to print the detection record 3 Just select a print mode either Print or Print to File to start printing 9 5 1 3 Print Diagnostic Report It is used to print the diagnostic report Operation Steps 1 Select Print Print Diagnosis only after any of the functions i e Fault Codes Data Streams...

Page 26: ... and the name of this file 2 Click the OK button to quit the function Screens hot 9 5 4 Help It is the on line help function for the VCI telling you how to operate the VCI and how to implement the diag nosis It works as an independent interface Operation Steps 1 Click the Help button on the main inter face of system to proceed to the Help interface 2 You may view the desired content through the na...

Page 27: ...pply 100V 240V 50 60HZ Power 5W Working temperature 10 45 C Storage temperature 15 50 C Relative humidity 95 Input voltage DC 7 32V USB Micro USB B LAN 10M 100M ethernet card KEY Recorder key LED 4 LED indicator lamps indicating the working status CPU FREESALE 16BIT microprocessor WLAN 802 11b Diagnosis switch array FULL for SAE J1962 Protection grade IP31 External battery Optional 12 Warranty R R...

Page 28: ...et out in the Council Directive1999 5 EC for radio equipment and telecommunications terminal equipment For the evaluation of the compliance with this Directive the following standards were applied Safety EN 61010 1 2010 Health EN 62311 2008 EMC EN 301 489 1 V1 9 2 EN 301 489 17V 2 1 1 EN61326 1 2006 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Radio EN 300 328 V1 9 1 Responsible for making ...

Page 29: ......

Page 30: ...Bosch Automotive Diagnostics Equipment Shenzhen Limited 5 F A Garden City Cyber Port Nanhai Road No 1079 Nanshan District Shenzhen 518067 China 400 000 5109 www bosch diagnostics com cn ...