DIVAR IP 7000 1U

DIP-7040-00N, DIP-7042-2HD, DIP-7042-4HD

 

 

en Installation Manual

 

Summary of Contents for DIVAR IP 7000 1U

Page 1: ...DIVAR IP 7000 1U DIP 7040 00N DIP 7042 2HD DIP 7042 4HD en Installation Manual ...

Page 2: ......

Page 3: ... 2 3 General system precautions 15 4 2 4 Rack mounting considerations 15 4 3 Rack mounting instructions 16 4 3 1 Identifying the sections of the rack rails 16 4 3 2 Installing the inner rails 17 4 3 3 Assembling the outer rails 17 4 3 4 Installing the outer rails to the rack 18 4 3 5 Installing the chassis into the rack 19 4 3 6 Installing the chassis into a Telco rack 20 4 4 Turning on the system...

Page 4: ... unit 29 9 Additional documentation and client software 30 10 Appendices 31 10 1 Motherboard 31 10 1 1 Motherboard layout 31 10 1 2 Motherboard component overview 32 10 1 3 Motherboard features 34 10 1 4 Block diagram 36 10 2 Chipset overview 36 10 3 PC health monitoring 37 10 4 Power configuration settings 37 10 5 Power supply 38 10 6 Super I O 38 10 7 iSCSI support 38 10 8 Overview of the Nuvoto...

Page 5: ...eight Always keep your back straight and lift with your legs Warning Interruption of mains supply Voltage is applied as soon as the mains plug is inserted into the mains socket However for devices with a mains switch the device is only ready for operation when the mains switch ON OFF is in the ON position When the mains plug is pulled out of the socket the supply of power to the device is complete...

Page 6: ...is symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of separately from household waste In the EU separate collecting systems are already in place for used electrical and electronic products Please dispose of these devices at your local communal waste collection point or at a recycling center Electrical safety precautions Basic ele...

Page 7: ...different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Do not use mats designed to decrease electrostatic discharge as prot...

Page 8: ... or uneven surfaces may cause the cart unit combination to overturn Mount the unit per the manufacturer s instructions FCC and ICES compliance only for U S A and Canada This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the e...

Page 9: ...s All components are pre installed and pre configured Simply connect to the network and turn on the unit DIVAR IP 7000 1U starts recording straight out of the box Access to Bosch VMS After starting the system immediate access to the Bosch VMS management application is offered by a customized user interface The ability to use one central user interface for configuration and operation management red...

Page 10: ...his manual Power supply Each chassis model includes 2 high efficiency power supplies redundant In the unlikely event your power supply fails replacement is simple and can be accomplished without tools Air shroud Air shrouds are shields usually plastic which conduct the airflow directly to where it is needed Always use the air shroud included with your chassis System interface There are several LED...

Page 11: ...t the system Power The main power switch is used to apply or remove power from the power supply to the server system Turning off system power with this button removes the main power but keeps standby power supplied to the system Therefore you must unplug system before servicing Control panel LEDs The control panel located on the front of the chassis has LEDs to provide you with critical informatio...

Page 12: ...and overheat indicators This chassis provides several options which may include hot swappable cold swappable and redundant power supplies Some power supplies include an LED in the rear with the following definitions Power supply LEDs Solid green Power supply is on Solid amber The power supply is plugged in and turned off or the system is off but in an abnormal state 2 3 3 12 en System overview DIV...

Page 13: ...ice We recommend using the respective Bosch hard disk drives The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates HDD not delivered from Bosch are not supported Information on supported HDDs can be found in the datasheet in the Bosch Online Product Catalog See also Installing additional drives page 25 3 DIVAR IP 7000 1U Inserting ha...

Page 14: ...hat is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Place the system near a grounded power outlet Leave approximately 25 inches clearance in front of the rack to be able to open the front door completely Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing Install the system only...

Page 15: ...ecautions page 5 Rack mounting considerations Ambient operating temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tm...

Page 16: ...rail will fit a rack between 26 and 33 5 deep Identifying the sections of the rack rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the chassis an outer fixed rack rail that secures directly to the rack itself 1 Rail extension inner rail is pre installed on the chassis 2 Outer...

Page 17: ...e of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated 4 Repeat steps for the other inner rail extension Assembling the outer rails To assemble the outer rails 1 Secure to the front of the rack ...

Page 18: ...f the outer rail must face the same direction in order to be secured to the rack 2 Adjust both sections of the outer rail to the proper length so that the rail fits snugly within the rack 3 Secure the longer section of the outer rail to the front of the rack with two M5 screws and the shorter section to the rear side of the rack with two M5 screws 4 Repeat steps for the remaining outer rail See al...

Page 19: ...has been pushed completely into the rack you should hear the locking tabs click 4 Optional Insert and tightening the thumbscrews that hold the front of the system to the rack Warning Do not pick up the unit with the front handles The handles are designed to pull the system from a rack only Warning Stability hazard Before sliding the unit out for servicing make sure that the rack stabilizing mechan...

Page 20: ...ositioned with just enough space to accommodate the width of the Telco rack Finish by sliding the chassis into the rack and tightening the brackets to the rack Turning on the system The last thing to be done is to provide input power to the system To turn on the system 1 Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and ...

Page 21: ...d IP addresses to the video devices Consult the local IT administrator to obtain a valid IP address range to be used with DIVAR IP and associated devices The default iSCSI settings are optimized for use with Bosch VMS VRM User with administrator rights User BVRAdmin Password WSS4Bosch Notice We strongly recommend not changing the user settings Changing the user settings can result in malfunctionin...

Page 22: ... displayed To do so press CTRL ALT DEL then hold down SHIFT while clicking the Switch User option and keep SHIFT pressed for about five seconds Notice We strongly recommend not changing any operating system settings Changing operating system settings can result in malfunctioning of the system See also Using Bosch VMS Config Wizard page 22 Adding additional licenses page 23 Recovering the unit page...

Page 23: ... Write down the computer signature or copy and paste it into a text file 6 On a computer with Internet access enter the following URL into your browser https activation boschsecurity com If you do not have an account to access the Bosch License Activation Center either create a new account recommended or click the link to activate a new license without logging on If you create an account and log o...

Page 24: ...n the Operator Client 4 The time line moves if the a camera is viewed in playback mode To perform further functionalities refer to the Bosch VMS manual Performance overview live 4CIF 2 5 Mbit 5 Mbit 10 Mbit Number of software monitors 20 13 9 720p 2 5 Mbit 5 Mbit 10 Mbit Number of software monitors 14 11 6 1080p 2 5 Mbit 5 Mbit 10 Mbit Number of software monitors 8 6 5 References to the manual are...

Page 25: ...Next 6 In the Specify Volume Size dialog box allow all of the automatically allocated space and click Next 7 In the Assign Drive Letter or Path dialog box click Assign the following drive letter enter the drive letter assigned to the new drive then click Next 8 In the Format Partition dialog box make sure the following settings are correct then click Next File system NTFS Allocation unit size Defa...

Page 26: ...erver Manager window the new virtual disks are displayed Adding and formatting the VHD as a VRM target To add and format the VHD as a VRM target 1 On the Bosch VMS default screen double click the Configuration Client icon to change device network settings The application starts 2 Enter the following then click OK User name admin Password no password required if not set with the wizard Connection 1...

Page 27: ... 8 Enter these port rules in the port forwarding settings of your internet router The DIVAR IP system is now accessible from the Internet Choosing an appropriate client There are two supported clients that allow remote connections to a DIVAR IP system through the internet Remote connection with Operator Client To make a remote connection with Bosch VMS Operator Client 1 Download the resource folde...

Page 28: ...ement Server on a separate server 1 Download the resource folder of the Bosch VMS installer using the following network share IP address of DIVAR IP sources 2 Copy the Setup directory to the server that should act as an Enterprise Management Server 3 In the Setup directory right click setup exe then click Run as administrator and accept the security message 4 In the Welcome dialog box clear all ch...

Page 29: ... factory default image data on the HDDs will not be deleted Note Windows performs the setup The screen displays the percentage of the process Notice Do not turn off the unit during the process This will damage the Recovery media 4 The unit starts from the Recovery media If the setup is successfull press Yes to restart the system 5 Windows performs the initial setup of the operating system The unit...

Page 30: ...security com select your region and your country start a search for your product select the product in the search results to show the existing documents And on the following network share 4 IP address of DIVAR IP sources 9 30 en Additional documentation and client software DIVAR IP 7000 1U 2014 12 V3 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 31: ...out Figure 10 1 Motherboard layout Important notes to the user Jumpers not indicated are for testing only When LE2 Onboard Power LED Indicator is on system power is on Unplug the power cable before installing or removing any components All systems have a SATA DOM connected to Serial ATA ports I SATA 5 with a small power connector DOM PWR SATA DOM Is plugged in connector I SATA 5 on the motherboard...

Page 32: ...abled 42 JBT1 CMOS Clear 40 JPES Energy Saving Feature Pins 2 3 Disabled 13 14 JI2C1 JI2C2 SMB to PCI Slots 17 JPG1 Onboard VGA Enable Pins 1 2 Enabled 11 12 JPL1 JPL2 LAN1 LAN2 Enable Pins 1 2 Enabled 24 JPT1 TPM Enable Pins 1 2 Enabled 10 JPB BMC Jumper Pins 1 2 Enabled 10 1 2 32 en Appendices DIVAR IP 7000 1U 2014 12 V3 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 33: ...21 I SATA 0 5 Serial ATA ports X8SIL has 4 Serial ATA Ports 2 IPMI IPMI LAN Port X8SIL F Only 35 JPI2C PWR supply I2C System Management Bus 31 SPKR1 Internal speaker buzzer 25 T SGPIO 0 1 Serial General Purpose IO headers for SATA 3 20 USB0 1 Backplane USB 0 1 19 USB 4 Type A USB Connector 18 USB 10 11 Front Panel USB header X8SIL F Only 22 DOM PWR Disk On Module DOM Power Connector 39 JTPM Truste...

Page 34: ...ntel 82574L Gigabit 10 100 1000 Mb s Ethernet Controllers for LAN 1 and LAN 2 ports Two 2 RJ 45 Rear IO Panel Connectors with Link and Activity LEDs Single Realtek RTL8201N PHY to support IPMI 2 0 X8SIL F Only I O Devices SATA Connections X8SIL F X8SIL V Only SATA Ports Six 6 RAID Windows RAID 0 1 5 10 RAID Linux RAID 0 1 10 SATA Connections X8SIL Only SATA Ports Four 4 Integrated IPMI 2 0 X8SIL F...

Page 35: ...er on mode for AC power recovery PC Health Monitoring CPU Monitoring Onboard voltage monitors for CPU core 3 3V 5V 12V 3 3V Stdby 5V Stdby VBAT HT Memory Chipset CPU 3 Phase switching voltage regulator CPU System overheat LED and control CPU Thermal Trip support Thermal Monitor 2 TM2 support Fan Control Fan status monitoring with firmware 4 pin Pulse Width Modulation fan speed control Low noise fa...

Page 36: ...nality and the capability of the single chip Intel 3400 chipset the X8SIL X8SIL F X8SIL V motherboard provides the performance and feature set required for single processor based systems with configuration options optimized for entry level server platforms The high speed Direct Media Interface DMI featured in the Intel 3400 3420 chipset enables the X8SIL X8SIL F X8SIL V motherboard to offer a high...

Page 37: ...ine the sensitivity of the voltage monitor by using SD III Fan status monitor with software PC health monitoring can check the RPM status of the cooling fans via Supero Doctor III CPU overheat LED and control This feature is available when the user enables the CPU overheat warning feature in the BIOS This allows the user to define an overheat temperature When this temperature reaches this pre defi...

Page 38: ...clock generator drive interface control logic and interrupt and DMA logic The wide range of functions integrated onto the Super I O greatly reduces the number of components required for interfacing with floppy disk drives The Super I O supports two 360 K 720 K 1 2 M 1 44 M or 2 88 M disk drives and data transfer rates of 250 Kb s 500 Kb s or 1 Mb s It also provides two high speed 16550 compatible ...

Page 39: ...ton BMC communicates with onboard components via six SMBus interfaces fan control Platform Environment Control Interface PECI buses and General Purpose I O T SGPIO ports It also includes the following features One X Bus parallel interface for expansion I O connections Three ADC inputs Analog and Digital Video outputs Two serial for boundary scan and debug There are two different versions of the Nu...

Page 40: ......

Page 41: ......

Page 42: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2014 ...