background image

DECT6000 System

Installation Instructions

en

Summary of Contents for DECT6000

Page 1: ...DECT6000 System Installation Instructions en ...

Page 2: ......

Page 3: ...5 Alphadesk central control PC 10 5 1 Functional description 10 5 2 Installation 11 5 2 1 Wiring the Alphadesk PC to the DCU distance less than 3 m 11 5 2 2 Wiring the Alphadesk PC to the DCU when distance longer than 3 m 12 6 Installing an Analogue Connection Unit ACU LBB 6725 xx and LBB 6726 xx 13 6 1 Functional description 13 6 2 Connectors 14 6 3 Installation 15 6 3 1 Installing an ACU card in...

Page 4: ...2 Controls and connectors 30 9 3 Installation 31 9 3 1 Mounting procedure 31 9 3 2 Wiring 32 9 3 3 Technical data of the power supply 32 9 3 4 Configuration repeater 33 9 4 Directional antenna LBB 6735 00 34 9 4 1 Functional description 34 9 4 2 Connectors 34 9 4 3 Installation 35 10 Link card package LBB 6722 00 36 10 1 Functional description 36 10 2 Connectors 37 10 3 Installation 38 10 3 1 Moun...

Page 5: ...he latest product data Abbreviations ACU Analogue Connection Unit LBB 6725 xx and LBB 6726 xx BS Base Station LBB 6730 01 DCU DECT6000 Control Unit LBB 6721 00 DECT Digital Enhanced Cordless Telecommunications ESD Electro Static Discharge PABX Private Automatic Branch Exchange PCB Printed Circuit Board PSTN Public Switched Telephone Network RF Radio Frequency UTP Unshielded Twisted Pair CHAPTER 1 ...

Page 6: ...central control PC A DECT6000 Control Unit DCU LBB 6721 00 Base Stations BS LBB 6730 01 Repeater s optional LBB 6734 01 Euro and LBB 6734 11 UK DECT6000 handsets LBB 670x 00 The Alphadesk central control PC controls paging calls within the DECT6000 system The DCU is connected to the telephone exchange PABX to make telephone calls possible Traffic channels for paging and telephone calls are control...

Page 7: ...e necessary e g position and mounting of the DCU The actions that have to be carried out to install a complete system are Determine position and number of base stations and repeaters using the DECT 6000 deployment kit Mounting base stations and repeaters Determine position of the DCU Hardware configuration of the DCU Mounting the DCU Installing the Alphadesk central control PC with the necessary s...

Page 8: ...he entire area cannot be covered e g A remote area which cannot be linked to the system with a cable you can use repeaters to extend the coverage area For information about repeaters see chapter 9 3 4 Location of the DCU The location of the DCU depends on the location of the PABX and base stations in order to minimise cable length The Alphadesk central control PC has to be placed close to the DCU ...

Page 9: ...1 The DCU has one or more max 8 Analogue Connection Units ACU because each handset needs also a connection with the PABX to make a telephone call Note The maximum distance between two DCUs is determined by the cable length of the link cable which is 1 metre CHAPTER 3 Installation Instructions DECT6000 5 9922 141 80271 03 07 en DCU configuration Maximum number of base stations Maximum number of ACU...

Page 10: ...ut an ACU The functions of the DCU are Controlling the base stations Powering the base stations Establishing the connection between the handsets and the PABX analogue lines Providing 2 way paging in combination with the Alphadesk central control PC CHAPTER 4 Installation Instructions 6 DECT6000 9922 141 80271 03 07 en Figure 4 1 DCU with mounting bracket ...

Page 11: ...optional extension card Base station interconnection PCB RS232 interconnection PCB Jumper 1 reset Jumper 2 master slave for settings see chapter 10 CHAPTER 4 Installation Instructions DECT6000 7 9922 141 80271 03 07 en 1 2 4 3 Link card not used not used ACU 7 ACU 6 ACU 5 ACU 4 ACU 3 ACU 2 ACU 1 ACU 0 BS 0 7 BS 8 15 Figure 4 2 Bottom view of the DCU BS 8 15 optional Power Supply BS 0 7 1 7 J2 J1 5...

Page 12: ...in the system 4 3 3 Installing an ACU The DCU must be equipped with at least one and maximum 8 ACUs to communicate with the PABX For information about how to install an ACU see chapter 6 4 3 4 Installing an extension card The DCU can be equipped with an extension card to connect 8 extra base stations For information about how to install an extension card see chapter 8 CHAPTER 4 Installation Instru...

Page 13: ...t them to the DCU refer to the documentation of the relevant item 4 3 6 Software configuration of the DCU Note After installing and wiring the DCU the software configuration has to take place This has to be done by use of the software installed on the Alphadesk central control PC described in the Instructions For Use of the LBB 6511 00 CHAPTER 4 Installation Instructions DECT6000 9 9922 141 80271 ...

Page 14: ...k central control PC refer to the Instructions For Use of the LBB 6511 00 Features of the basic software package LBB 6511 00 Integrates the DECT6000 system with DP 6000 paging Provides paging features to DECT6000 systems Configuration of DECT6000 control unit DCU Subscription of DECT6000 handsets Transmission of normal urgent emergency and mailbox messages Reception of paging message results Enabl...

Page 15: ... 110 230 Vac 50 60 Hz 1 6A Fuse T3 15 Ah 250 Vac On Off switch Note The maximum length of the RS232 cable is 3 metres CHAPTER 5 Installation Instructions DECT6000 11 9922 141 80271 03 07 en 1 2 4 3 Link card not used not used ACU 7 ACU 6 ACU 5 ACU 4 ACU 3 ACU 2 ACU 1 ACU 0 BS 0 7 BS 8 15 Figure 5 1 Bottom view of the DCU DCU Alphadesk central control PC 9 pole D connector female 9 pole D connector...

Page 16: ...when distance longer than 3 m In case the distance between the Alphadesk central control PC and the DCU is longer than 3 metres you have to use a modem or RS485 converter CHAPTER 5 Installation Instructions 12 DECT6000 9922 141 80271 03 07 en ...

Page 17: ... galvanic isolation between the DECT6000 system and the PABX One DCU can contain up to 8 ACUs Figure 6 1 and 6 2 shows the situation without and with the use of a DCU If possible existing telephone wiring may be used as shown in example below CHAPTER 6 Installation Instructions DECT6000 13 9922 141 80271 03 07 en PABX Terminal strip Terminal strip Figure 6 1 Normal telephone system PABX DCU Termin...

Page 18: ...le For connections see chapter 6 3 2 CHAPTER 6 Installation Instructions 14 DECT6000 9922 141 80271 03 07 en Type number Country code Country LBB 6725 or LBB 6726 00 Most countries except LBB 6725 10 France LBB 6725 or LBB 6726 20 The Netherlands LBB 6725 or LBB 6726 30 South Africa LBB 6725 or LBB 6726 40 Poland Table 6 1 Available types of ACU 2 1 Figure 6 3 Connectors of the ACU ...

Page 19: ...tion refer to the Installation Instructions on the CD ROM delivered with the DCU Warning Disconnect the main power supply before any work is carried out on the DECT6000 system Caution When work is carried out on the DCU wear an anti ESD bracelet to prevent damage to the PCBs CHAPTER 6 Installation Instructions DECT6000 15 9922 141 80271 03 07 en ...

Page 20: ...late with a screwdriver see figure 6 4 5 Place the ACU in the first available slot ACU0 ACU7 see figure 6 5 6 Screw the ACU to the DCU housing with a Pozidrive size 1 screwdriver and the two supplied screws 7 Close the DCU CHAPTER 6 Installation Instructions 16 DECT6000 9922 141 80271 03 07 en BS 0 7 BS 8 15 1 1 2 2 2 2 Link card not used not used ACU 7 ACU 6 ACU 5 ACU 4 ACU 3 ACU 2 ACU 1 ACU 0 Fi...

Page 21: ...he wires going to the PABX lines to a 25 pole female sub D connector according the pin configuration in Table 6 2 and plug the connector on the PABX connector of the ACU card CHAPTER 6 Installation Instructions DECT6000 17 9922 141 80271 03 07 en Pin Signal Line Pin Signal Line 1 b 0 7 b 4 14 a 20 a 2 earth 8 earth 3 b 1 9 b 5 15 a 21 a 16 earth 22 earth 4 b 2 10 b 6 17 a 23 a 5 earth 11 earth 6 b...

Page 22: ...se of the LBB 6511 00 CHAPTER 6 Installation Instructions 18 DECT6000 9922 141 80271 03 07 en Pin Signal Wire colour Line Pin Signal Wire colour Line 14 a white blue 0 20 a white grey 4 1 b blue white 7 b grey white 2 earth red grey 8 earth black blue 15 a white orange 1 21 a red blue 5 3 b orange white 9 b blue red 16 earth black orange 22 earth red brown 17 a white green 2 23 a red orange 6 4 b ...

Page 23: ...e DCU has to be done by use of an unshielded twisted pair cable with a maximum length of 2 km If possible old cable wiring may be used Features of the base station Supports antenna diversity Supports handover between the RF channels under the same base station Can handle four DECT speech channels simultaneously Frame synchronise with other base stations under the same DECT control unit DCU CHAPTER...

Page 24: ...TER 7 Installation Instructions 20 DECT6000 9922 141 80271 03 07 en PABX DCU Terminal strip Terminal strip BS BS BS DCU connection cable ACU PABX connection cable BS BS Figure 7 3 Telephone system integrated with DECT using existing cabling 1 Figure 7 4 Base station connectors ...

Page 25: ...ugs 4 Pull the unshielded twisted pair cable max length 2 km through the orifice in the wall holder Make sure to leave enough cable length to facilitate connection of the RJ11 plug and dis mounting of the base station 5 Mount the wall holder using the screws provided The base station can now simply be attached to the wall holder push down and click in position CHAPTER 7 Installation Instructions D...

Page 26: ...ays One way is to solder the 25 pole male sub D connector to the base station cables see 1 the other way is buying a BS DCU connection cable LBB 6721 02 see 2 1 Soldering the wires to a 25 pole male sub D connector according the pin configuration in Table 7 1 and plug the connector on the BS connector of the DCU see figure 7 7 CHAPTER 7 Installation Instructions 22 DECT6000 9922 141 80271 03 07 en...

Page 27: ... a cable delay measurement This has to be done by use of the software installed on the Alphadesk central control PC described in the Instructions For Use of the LBB 6511 00 CHAPTER 7 Installation Instructions DECT6000 23 9922 141 80271 03 07 en 1 2 4 3 Link card not used not used ACU 7 ACU 6 ACU 5 ACU 4 ACU 3 ACU 2 ACU 1 ACU 0 BS 0 7 BS 8 15 Figure 7 7 Botttom view of the DCU Pin Signal Wire colou...

Page 28: ... the DECT6000 system A DCU equipped with an extension card enables up to 8 extra base stations to be connected Only one extension card can be mounted into a DCU 8 2 Connectors DCU slot connector Base station BS 8 15 connector 25 pole female CHAPTER 8 Installation Instructions 24 DECT6000 9922 141 80271 03 07 en Figure 8 1 Extension card 2 1 Figure 8 2 Extension card connectors ...

Page 29: ... For more information refer to the Installation Instructions on the CD ROM delivered with the DCU Warning Disconnect the main power supply before any work is carried out on the DECT6000 system Caution When work is carried out on the DCU wear an anti ESD bracelet to prevent damage to the PCBs CHAPTER 8 Installation Instructions DECT6000 25 9922 141 80271 03 07 en ...

Page 30: ...er see figure 8 3 5 Insert the two plastic pins in the DCU main board 6 Mount the extension card into the DCU main board see figure 8 4 7 Screw the extension card connector to the DCU housing see figure 8 4 8 Close the DCU CHAPTER 8 Installation Instructions 26 DECT6000 9922 141 80271 03 07 en BS 0 7 BS 8 15 1 1 2 2 2 2 Link card not used not used ACU 7 ACU 6 ACU 5 ACU 4 ACU 3 ACU 2 ACU 1 ACU 0 Fi...

Page 31: ...erminal strip located near by a PABX to the base stations see figure 8 5 For wiring of the BS DCU connection cable LBB 6721 02 see Table 8 2 CHAPTER 8 Installation Instructions DECT6000 27 9922 141 80271 03 07 en Pin Signal Line Pin Signal Line 1 a 8 5 a 12 14 b 18 b 2 a 9 6 a 13 15 b 19 b 3 a 10 7 a 14 16 b 20 b 4 a 11 8 a 15 17 b 21 b 9 13 Not connected 22 25 Not connected Table 8 1 Base station...

Page 32: ...t This has to be done by use of the software installed on the Alphadesk central control PC described in the Instructions For Use of the LBB 6511 00 CHAPTER 8 Installation Instructions 28 DECT6000 9922 141 80271 03 07 en PABX DCU Terminal strip Terminal strip BS BS BS DCU connection cable ACU PABX connection cable BS BS Figure 8 5 Telephone system integrated with DECT using a BS DCU connection cabl...

Page 33: ...ly In case the repeater is inside the coverage area of the base station no directional antenna is required situation 1 If the repeater is outside the coverage area a directional antenna is required situation 2 When using a directional antenna the distance between the base station and the repeater can be extended up to 1000 metres depending on environmental conditions Note Both the base station and...

Page 34: ...nnectors Connector for directional antenna Red LED power on RJ11 power inlet programming connector CHAPTER 9 Installation Instructions 30 DECT6000 9922 141 80271 03 07 en 1 2 3 Figure 9 3 Repeater controls and connectors ...

Page 35: ...ill two holes of 6 mm 3 Mount the supplied plugs 4 Pull the power supply cable through the orifice in the wall holder Make sure to leave enough cable length to facilitate dis mounting of the repeater 5 Mount the wall holder using the screws provided The repeater can now simply be attached to the wall holder push down and click in position CHAPTER 9 Installation Instructions DECT6000 31 9922 141 80...

Page 36: ... the line connector of the repeater 2 Insert the adapter into the wall socket The inset in fig 9 5 shows the connections of the RJ11 connector of the power supply cable 9 3 3 Technical data of the power supply Input voltage 230 Vac 50 Hz 60 mA 12W Output voltage 2 x 9 Vdc 300 mA CHAPTER 9 Installation Instructions 32 DECT6000 9922 141 80271 03 07 en 1 2 GND 9V 3 Figure 9 5 RJ11 connector of the po...

Page 37: ...nnect the serial cable to the modular connector adapter There is no requirement as to polarity or position of the connectors 2 Connect the modular connector adapter to the repeater 3 Connect the mains adapter to the mains 4 Connect the serial cable to the COM port of your computer 5 Switch on your laptop 6 Program the repeater CHAPTER 9 Installation Instructions DECT6000 33 9922 141 80271 03 07 en...

Page 38: ...directional antenna is required When using a directional antenna the distance between the base station and the repeater can be extended up to 1000 metres 9 4 2 Connectors Connection cable approx 1 metre Antenna connector CHAPTER 9 Installation Instructions 34 DECT6000 9922 141 80271 03 07 en 1 3 2 Figure 9 7 Extension of coverage area with directional antenna 2 1 Figure 9 8 Directional antenna wit...

Page 39: ...the directional antenna it is advisable that you use an adjustable support for pointing the antenna to the base station Positioning the directional antenna Connect the directional antenna to the antenna connector of the deployment handset Use the deployment handset to position the directional antenna in the position with the strongest signal CHAPTER 9 Installation Instructions DECT6000 35 9922 141...

Page 40: ... OK R 1 MENU 2 3 4 5 6 7 8 9 0 ABC JKL TUV DEF MNO WXYZ GHI PQRS OK R 1 MENU 2 3 4 5 6 7 8 9 0 ABC JKL TUV DEF MNO WXYZ GHI PQRS OK R 1 MENU 2 3 4 5 6 7 8 9 0 ABC JKL TUV DEF MNO WXYZ GHI PQRS BS BS BS OK R 1 MENU 2 3 4 5 6 7 8 9 0 ABC JKL TUV DEF MNO WXYZ GHI PQRS OK R 1 MENU 2 3 4 5 6 7 8 9 0 ABC JKL TUV DEF MNO WXYZ GHI PQRS OK R 1 MENU 2 3 4 5 6 7 8 9 0 ABC JKL TUV DEF MNO WXYZ GHI PQRS slave ...

Page 41: ... A sticker on the bracket identifies the master and slave card 10 2 Connectors DCU slot connector Slave Master connector CHAPTER 10 Installation Instructions DECT6000 37 9922 141 80271 03 07 en master slave Figure 10 2 Link card package 2 1 Figure 10 3 Link card connectors ...

Page 42: ...have the same software version Note For more information refer to the Installation Instructions on the CD ROM delivered with the DCU Warning Disconnect the main power supply before any work is carried out on the DECT6000 system Caution When work is carried out on the DCU wear an anti ESD bracelet to prevent damage to the PCBs CHAPTER 10 Installation Instructions 38 DECT6000 9922 141 80271 03 07 en...

Page 43: ...see figure 10 4 5 Install the master link card in the DCU which is connected to the Alphadesk central control PC and the slave link card in the other DCU see figure 10 5 6 Check if jumper J2 of the master DCU is closed 7 Open jumper J2 of the slave DCU see figure 10 6 8 Close both DCUs CHAPTER 10 Installation Instructions DECT6000 39 9922 141 80271 03 07 en BS 0 7 BS 8 15 1 1 2 2 2 2 Link card not...

Page 44: ... other by use of the supplied link cable figure 10 7 Note The length of the link cable is 1 metre Do not extend the length of this cable CHAPTER 10 Installation Instructions 40 DECT6000 9922 141 80271 03 07 en J1 J2 Figure 10 6 Jumper settings 15 pole D connector Female Slave DCU Master DCU 15 pole D connector Male Figure 10 7 Link cable ...

Page 45: ...ral control PC described in the Instructions For Use of the LBB 6511 00 CHAPTER 10 Installation Instructions DECT6000 41 9922 141 80271 03 07 en Master DCU Pin Wire colour Slave DCU Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Yellow Green Purple Grey Pink Red Black Blue Blue red Grey pink Brown Not connected Not connected Not connected Not connected 8 7 6 5 4 3 2 1 15 14 13 12 11 10 9 Table 10 2 Link ...

Page 46: ......

Page 47: ......

Page 48: ... Bosch Security Systems B V Data subject to change without notice 2003 07 9922 141 80271 For more information visit www boschsecuritysystems com ...

Reviews: